133 related articles for article (PubMed ID: 34290171)
1. Measurement of dental implant stability by two different techniques.
Kocak-Buyukdere A; Kayabay G
Niger J Clin Pract; 2021 Jul; 24(7):973-977. PubMed ID: 34290171
[TBL] [Abstract][Full Text] [Related]
2. A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell Mentor.
Oh JS; Kim SG; Lim SC; Ong JL
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Apr; 107(4):513-8. PubMed ID: 19095473
[TBL] [Abstract][Full Text] [Related]
3. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial.
Zix J; Hug S; Kessler-Liechti G; Mericske-Stern R
Int J Oral Maxillofac Implants; 2008; 23(3):525-30. PubMed ID: 18700378
[TBL] [Abstract][Full Text] [Related]
4. Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment.
Oh JS; Kim SG
Oral Surg Oral Med Oral Pathol Oral Radiol; 2012 Mar; 113(3):e35-40. PubMed ID: 22669155
[TBL] [Abstract][Full Text] [Related]
5. Correlation of Implant Stability Between Two Noninvasive Methods Using Submerged and Nonsubmerged Healing Protocols: A Randomized Clinical Trial.
AAl MA; El Far M; Sheta NM; Fayyad A; El Desouky E; Nabi NA; Ibrahim M
J Oral Implantol; 2020 Dec; 46(6):571-579. PubMed ID: 33494103
[TBL] [Abstract][Full Text] [Related]
6. The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study.
Bilhan H; Cilingir A; Bural C; Bilmenoglu C; Sakar O; Geckili O
J Oral Implantol; 2015 Aug; 41(4):e90-5. PubMed ID: 24593232
[TBL] [Abstract][Full Text] [Related]
7. Validation of an implant stability measurement device using the percussion response: a clinical research study.
Okuhama Y; Nagata K; Kim H; Tsuruoka H; Atsumi M; Kawana H
BMC Oral Health; 2022 Jul; 22(1):286. PubMed ID: 35836169
[TBL] [Abstract][Full Text] [Related]
8. Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis.
Winter W; Möhrle S; Holst S; Karl M
Int J Oral Maxillofac Implants; 2010; 25(3):532-9. PubMed ID: 20556252
[TBL] [Abstract][Full Text] [Related]
9. Measurement of mini-implant stability using resonance frequency analysis.
Nienkemper M; Wilmes B; Panayotidis A; Pauls A; Golubovic V; Schwarz F; Drescher D
Angle Orthod; 2013 Mar; 83(2):230-8. PubMed ID: 22931201
[TBL] [Abstract][Full Text] [Related]
10. Resonance frequency analysis: Comparing two clinical instruments.
Becker W; Hujoel P; Becker BE
Clin Implant Dent Relat Res; 2018 Jun; 20(3):308-312. PubMed ID: 29532586
[TBL] [Abstract][Full Text] [Related]
11. Modal damping factor detected with an impulse-forced vibration method provides additional information on osseointegration during dental implant healing.
Feng SW; Chang WJ; Lin CT; Lee SY; Teng NC; Huang HM
Int J Oral Maxillofac Implants; 2015; 30(6):1333-40. PubMed ID: 26574858
[TBL] [Abstract][Full Text] [Related]
12. Comparative analysis of 2 resonance frequency measurement devices: Osstell Mentor and Osstell ISQ.
Jaramillo R; Santos R; Lázaro P; Romero M; Rios-Santos JV; Bullón P; Fernández-Palacín A; Herrero-Climent M
Implant Dent; 2014 Jun; 23(3):351-6. PubMed ID: 24776942
[TBL] [Abstract][Full Text] [Related]
13. Torsional resonance frequency analysis: a novel method for assessment of dental implant stability.
Tang YL; Li B; Jin W; Li DH
Clin Oral Implants Res; 2015 Jun; 26(6):615-22. PubMed ID: 24611966
[TBL] [Abstract][Full Text] [Related]
14. Correlation between Periotest value and implant stability quotient: a systematic review.
Semenzin Rodrigues A; de Moraes Melo Neto CL; Santos Januzzi M; Dos Santos DM; Goiato MC
Biomed Tech (Berl); 2024 Feb; 69(1):1-10. PubMed ID: 37489593
[TBL] [Abstract][Full Text] [Related]
15. Osstell Resonance Frequency Measurement Values as a Prognostic Factor in Implant Dentistry.
Krafft T; Graef F; Karl M
J Oral Implantol; 2015 Aug; 41(4):e133-7. PubMed ID: 24766132
[TBL] [Abstract][Full Text] [Related]
16. Reliability of 2 implant stability measuring methods in assessment of various periimplant bone loss: an in vitro study with the Periotest and Osstell Mentor.
Choi HH; Chung CH; Kim SG; Son MK
Implant Dent; 2014 Feb; 23(1):51-6. PubMed ID: 24398847
[TBL] [Abstract][Full Text] [Related]
17. Resonance Frequency Analysis of Thermal Acid-Etched, Hydrophilic Implants During First 3 Months of Healing and Osseointegration in an Early-Loading Protocol.
van Eekeren P; Said C; Tahmaseb A; Wismeijer D
Int J Oral Maxillofac Implants; 2015; 30(4):843-50. PubMed ID: 26252037
[TBL] [Abstract][Full Text] [Related]
18. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study.
Balleri P; Cozzolino A; Ghelli L; Momicchioli G; Varriale A
Clin Implant Dent Relat Res; 2002; 4(3):128-32. PubMed ID: 12516644
[TBL] [Abstract][Full Text] [Related]
19. Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study.
Zix J; Kessler-Liechti G; Mericske-Stern R
Int J Oral Maxillofac Implants; 2005; 20(5):747-52. PubMed ID: 16274149
[TBL] [Abstract][Full Text] [Related]
20. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: II. Implant surface modifications and implant diameter.
Han J; Lulic M; Lang NP
Clin Oral Implants Res; 2010 Jun; 21(6):605-11. PubMed ID: 20666787
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]