235 related articles for article (PubMed ID: 34293731)
1. Simulation study of potential time-of-flight capabilities for a multilayer DOI-PET detector with an independent readout structure.
Watanabe M; Moriya T; Uchida H; Omura T
Phys Med Biol; 2021 Sep; 66(18):. PubMed ID: 34293731
[TBL] [Abstract][Full Text] [Related]
2. Performance of long rectangular semi-monolithic scintillator PET detectors.
Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
[TBL] [Abstract][Full Text] [Related]
3. A thick semi-monolithic scintillator detector for clinical PET scanners.
Zhang C; Wang X; Sun M; Kuang Z; Zhang X; Ren N; Wu S; Sang Z; Sun T; Hu Z; Yang Y; Liu Z
Phys Med Biol; 2021 Mar; 66(6):065023. PubMed ID: 33709958
[TBL] [Abstract][Full Text] [Related]
4. A semi-monolithic detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-capabilities for clinical PET applications.
Mueller F; Naunheim S; Kuhl Y; Schug D; Solf T; Schulz V
Med Phys; 2022 Dec; 49(12):7469-7488. PubMed ID: 36259245
[TBL] [Abstract][Full Text] [Related]
5. Simulation study of a brain PET scanner using TOF-DOI detectors equipped with first interaction position detection.
Li Y; Watanabe M; Isobe T; Ote K; Tokui A; Omura T; Liu H
Phys Med Biol; 2022 Dec; 68(1):. PubMed ID: 36560889
[No Abstract] [Full Text] [Related]
6. An edge-readout, multilayer detector for positron emission tomography.
Li X; Ruiz-Gonzalez M; Furenlid LR
Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
[TBL] [Abstract][Full Text] [Related]
7. A layered single-side readout depth of interaction time-of-flight-PET detector.
Bläckberg L; Sajedi S; El Fakhri G; Sabet H
Phys Med Biol; 2021 Feb; 66(4):045025. PubMed ID: 33570050
[TBL] [Abstract][Full Text] [Related]
8. A sub-millimeter resolution PET detector module using a multi-pixel photon counter array.
Song TY; Wu H; Komarov S; Siegel SB; Tai YC
Phys Med Biol; 2010 May; 55(9):2573-87. PubMed ID: 20393236
[TBL] [Abstract][Full Text] [Related]
9. Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals.
Cucarella N; Barrio J; Lamprou E; Valladares C; Benlloch JM; Gonzalez AJ
Med Phys; 2021 Dec; 48(12):8010-8023. PubMed ID: 34723380
[TBL] [Abstract][Full Text] [Related]
10. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
[TBL] [Abstract][Full Text] [Related]
11. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.
Son JW; Lee MS; Lee JS
Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613
[TBL] [Abstract][Full Text] [Related]
12. Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation.
Borghi G; Tabacchini V; Schaart DR
Phys Med Biol; 2016 Jul; 61(13):4904-28. PubMed ID: 27285955
[TBL] [Abstract][Full Text] [Related]
13. A CNN-based four-layer DOI encoding detector using LYSO and BGO scintillators for small animal PET imaging.
He W; Zhao Y; Zhao X; Huang W; Zhang L; Prout DL; Chatziioannou AF; Ren Q; Gu Z
Phys Med Biol; 2023 Apr; 68(9):. PubMed ID: 37040784
[No Abstract] [Full Text] [Related]
14. Timing advances of commercial divalent-ion co-doped LYSO:Ce and SiPMs in sub-100 ps time-of-flight positron emission tomography.
Nadig V; Herweg K; Chou MMC; Lin JWC; Chin E; Li CA; Schulz V; Gundacker S
Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36808914
[No Abstract] [Full Text] [Related]
15. Monte Carlo calculations of PET coincidence timing: single and double-ended readout.
Derenzo SE; Choong WS; Moses WW
Phys Med Biol; 2015 Sep; 60(18):7309-38. PubMed ID: 26350162
[TBL] [Abstract][Full Text] [Related]
16. Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET.
Cates JW; Choong WS; Brubaker E
Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38252971
[No Abstract] [Full Text] [Related]
17. Analysis of a convex time skew calibration for light sharing-based PET detectors.
Naunheim S; Kuhl Y; Solf T; Schug D; Schulz V; Mueller F
Phys Med Biol; 2023 Jan; 68(2):. PubMed ID: 36595338
[No Abstract] [Full Text] [Related]
18. Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET.
Gundacker S; Auffray E; Pauwels K; Lecoq P
Phys Med Biol; 2016 Apr; 61(7):2802-37. PubMed ID: 26982798
[TBL] [Abstract][Full Text] [Related]
19. Development of a dual-ended readout detector with segmented crystal bars made using a subsurface laser engraving technique.
Mohammadi A; Yoshida E; Nishikido F; Nitta M; Shimizu K; Sakai T; Yamaya T
Phys Med Biol; 2018 Jan; 63(2):025019. PubMed ID: 29176052
[TBL] [Abstract][Full Text] [Related]
20. A multi-resolution TOF-DOI detector for human brain dedicated PET scanner.
He W; Zhao Y; Huang W; Zhao X; Niu M; Yang H; Zhang L; Ren Q; Gu Z
Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38181423
[No Abstract] [Full Text] [Related]
[Next] [New Search]