These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
123 related articles for article (PubMed ID: 34300870)
1. The Effectiveness of Active Screen Method in Ion Nitriding Grade 5 Titanium Alloy. Frączek T; Prusak R; Ogórek M; Skuza Z Materials (Basel); 2021 Jul; 14(14):. PubMed ID: 34300870 [TBL] [Abstract][Full Text] [Related]
2. Impact of Glow-Discharge Nitriding Technology on the Properties of 3D-Printed Grade 2 Titanium Alloy. Kamiński J; Sitek R; Adamczyk-Cieślak B; Kulikowski K Materials (Basel); 2024 Sep; 17(18):. PubMed ID: 39336333 [TBL] [Abstract][Full Text] [Related]
3. Tribological Behavior of Titanium Alloy Treated by Nitriding and Surface Texturing Composite Technology. Kang J; Wang M; Yue W; Fu Z; Zhu L; She D; Wang C Materials (Basel); 2019 Jan; 12(2):. PubMed ID: 30669339 [TBL] [Abstract][Full Text] [Related]
5. Improvement of titanium alloy for biomedical applications by nitriding and carbonitriding processes under glow discharge conditions. Czarnowska E; Wierzchoń T; Maranda-Niedbała A; Karczmarewicz E J Mater Sci Mater Med; 2000 Feb; 11(2):73-81. PubMed ID: 15348050 [TBL] [Abstract][Full Text] [Related]
6. Corrosion Behavior of Nitrided Layer of Ti6Al4V Titanium Alloy by Hollow Cathodic Plasma Source Nitriding. Zhang L; Shao M; Zhang Z; Yi X; Yan J; Zhou Z; Fang D; He Y; Li Y Materials (Basel); 2023 Apr; 16(8):. PubMed ID: 37109798 [TBL] [Abstract][Full Text] [Related]
7. Nitriding of 316L Steel in a Glow Discharge Plasma. Frączek T; Prusak R; Ogórek M; Skuza Z Materials (Basel); 2022 Apr; 15(9):. PubMed ID: 35591416 [TBL] [Abstract][Full Text] [Related]
8. Elastic-plastic properties of titanium and its alloys modified by fibre laser surface nitriding for orthopaedic implant applications. Shirazi HA; Chan CW; Lee S J Mech Behav Biomed Mater; 2021 Dec; 124():104802. PubMed ID: 34474322 [TBL] [Abstract][Full Text] [Related]
9. Optimization of anti-wear and anti-bacterial properties of beta TiNb alloy via controlling duty cycle in open-air laser nitriding. Chang X; Smith GC; Quinn J; Carson L; Chan CW; Lee S J Mech Behav Biomed Mater; 2020 Oct; 110():103913. PubMed ID: 32957212 [TBL] [Abstract][Full Text] [Related]
10. [Bio-tribological properties of dental prosthesis made of nitriding titanium alloy material]. Li H; Luo J; Qin T; Li J; Feng J; Huang W; He X Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Apr; 21(2):261-3. PubMed ID: 15143554 [TBL] [Abstract][Full Text] [Related]
11. Enhancement of the biocompatibility by surface nitriding of a low-modulus titanium alloy for dental implant applications. Bédouin Y; Gordin DM; Pellen-Mussi P; Pérez F; Tricot-Doleux S; Vasilescu C; Drob SI; Chauvel-Lebret D; Gloriant T J Biomed Mater Res B Appl Biomater; 2019 Jul; 107(5):1483-1490. PubMed ID: 30265783 [TBL] [Abstract][Full Text] [Related]
12. Microstructure and biocompatibility of titanium oxides produced on nitrided surface layer under glow discharge conditions. Czarnowska E; Morgiel J; Ossowski M; Major R; Sowinska A; Wierzchon T J Nanosci Nanotechnol; 2011 Oct; 11(10):8917-23. PubMed ID: 22400281 [TBL] [Abstract][Full Text] [Related]
13. Structure and Wear Performance of a Titanium Alloy by Using Low-Temperature Plasma Oxy-Nitriding. Li H; Wang H; Wang S; Yang Y; Niu Y; Zhu S; Wang F Materials (Basel); 2023 May; 16(10):. PubMed ID: 37241236 [TBL] [Abstract][Full Text] [Related]
14. Study of the Role of Titanium and Iron Cathodic Cages on Plasma-Nitrided AISI 430 Ferritic Stainless Steel. Babur MZ; Noori AS; Iqbal Z; Shafiq M; Asghar M; Alghtani AH; Tirth V; Algahtani A; Zaman A Micromachines (Basel); 2022 Oct; 13(10):. PubMed ID: 36296092 [TBL] [Abstract][Full Text] [Related]
15. Wear Resistance of Ti-6Al-4V Alloy Ball Heads for Use in Implants. Skvortsova S; Orlov A; Valyano G; Spektor V; Mamontova N J Funct Biomater; 2021 Nov; 12(4):. PubMed ID: 34842763 [TBL] [Abstract][Full Text] [Related]
16. Rapid Nitriding of Titanium Alloy with Fine Grains at Room Temperature. Fujita K; Ijiri M; Inoue Y; Kikuchi S Adv Mater; 2021 May; 33(20):e2008298. PubMed ID: 33939219 [TBL] [Abstract][Full Text] [Related]
17. Nitriding Effect on the Tribological Performance of CrN-, AlTiN-, and CrN/AlTiN-Coated DIN 1.2367 Hot Work Tool Steel. Aktaş Çelik G; Atapek ŞH; Polat Ş; Obrosov A; Weiß S Materials (Basel); 2023 Mar; 16(7):. PubMed ID: 37049099 [TBL] [Abstract][Full Text] [Related]
18. Effect of plasma nitriding treatment on structural, tribological and electrochemical properties of commercially pure titanium. Çelik İ; Karakan M Proc Inst Mech Eng H; 2016 Feb; 230(2):145-52. PubMed ID: 26666885 [TBL] [Abstract][Full Text] [Related]
20. [Experimental study on the corrosion behavior of a type of oral near β-type titanium alloys modified with double glow plasma nitriding]. Wen K; Li F Zhonghua Kou Qiang Yi Xue Za Zhi; 2015 Dec; 50(12):751-4. PubMed ID: 26887401 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]