These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 3431403)

  • 41. A fully automated method for accurate measurement of geometrical distortion in magnetic resonance imaging of a 3D-lattice phantom.
    Mangione S; Acquaviva R; Garbo G
    Magn Reson Imaging; 2019 Apr; 57():8-18. PubMed ID: 30393141
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Evaluation of biexponential relaxation processes by magnetic resonance imaging. A phantom study.
    Kjaer L; Thomsen C; Larsson HB; Henriksen O; Ring P
    Acta Radiol; 1988; 29(4):473-9. PubMed ID: 3408610
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Parameter-weighted MR images and their optimization: theory and example of images for the flash sequence compared to the spin-echo sequence].
    Kölbel G; Klose U; Hess CF; Küper K; Grodd W
    Rofo; 1988 Jun; 148(6):674-82. PubMed ID: 2837805
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A new pulse sequence for "fast recovery" fast-scan NMR imaging.
    Iwaoka H; Sugiyama T; Matsuura H; Fujino K
    IEEE Trans Med Imaging; 1984; 3(1):41-6. PubMed ID: 18234609
    [TBL] [Abstract][Full Text] [Related]  

  • 45. An adiabatic multiple spin-echo pulse sequence: removal of systematic errors due to pulse imperfections and off-resonance effects.
    Zweckstetter M; Holak TA
    J Magn Reson; 1998 Jul; 133(1):134-47. PubMed ID: 9654478
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Design of universal parallel-transmit refocusing k
    Gras V; Mauconduit F; Vignaud A; Amadon A; Le Bihan D; Stöcker T; Boulant N
    Magn Reson Med; 2018 Jul; 80(1):53-65. PubMed ID: 29193250
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain.
    Melhem ER; Bert RJ; Walker RE
    AJR Am J Roentgenol; 1998 Sep; 171(3):803-7. PubMed ID: 9725320
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Observation of bi-exponential T(1ρ) relaxation of in-vivo rat muscles at 3T.
    Yuan J; Zhao F; Chan Q; Wang YX
    Acta Radiol; 2012 Jul; 53(6):675-81. PubMed ID: 22761346
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Cooperative T1 and T2 effects on contrast using a new driven inversion spin-echo (DISE) MRI pulse sequence.
    Conturo TE; Kessler RM; Beth AH
    Magn Reson Med; 1990 Sep; 15(3):397-419. PubMed ID: 2233220
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements.
    Xanthis CG; Bidhult S; Kantasis G; Heiberg E; Arheden H; Aletras AH
    J Cardiovasc Magn Reson; 2015 Nov; 17():104. PubMed ID: 26610703
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Technical note: reducing motion artifacts in in vivo magnetic resonance imaging measurements of relaxation times.
    Gowland PA; Leach MO; Tanner SF
    Br J Radiol; 1994 Dec; 67(804):1249-57. PubMed ID: 7874426
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies.
    Cernicanu A; Axel L
    Acad Radiol; 2006 Jun; 13(6):686-93. PubMed ID: 16679270
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Simultaneous acquisition of pulse EPR orientation selective spectra.
    Kaminker I; Florent M; Epel B; Goldfarb D
    J Magn Reson; 2011 Jan; 208(1):95-102. PubMed ID: 21075028
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Two-pulse biexponential-weighted 23Na imaging.
    Benkhedah N; Bachert P; Nagel AM
    J Magn Reson; 2014 Mar; 240():67-76. PubMed ID: 24530955
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Effects of RF pulse profile and intra-voxel phase dispersion on MR fingerprinting with balanced SSFP readout.
    Chiu SC; Lin TM; Lin JM; Chung HW; Ko CW; Büchert M; Bock M
    Magn Reson Imaging; 2017 Sep; 41():80-86. PubMed ID: 28412455
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Measurement of spin-lattice relaxation times and concentrations in systems with chemical exchange using the one-pulse sequence: breakdown of the Ernst model for partial saturation in nuclear magnetic resonance spectroscopy.
    Spencer RG; Fishbein KW
    J Magn Reson; 2000 Jan; 142(1):120-35. PubMed ID: 10617442
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Pancreatic enhancement and pulse sequence analysis using low-dose mangafodipir trisodium.
    Mayo-Smith WW; Schima W; Saini S; Slater GJ; McFarland EG
    AJR Am J Roentgenol; 1998 Mar; 170(3):649-52. PubMed ID: 9490946
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Reproducibility of spin lattice relaxation time (T1) measurement using an 0.08 tesla MD 800 magnetic resonance imager.
    Richards MA; Gregory WM; Webb JA; Jewell SE; Reznek RH
    Br J Radiol; 1987 Mar; 60(711):241-4. PubMed ID: 3567470
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Spectroscopic imaging using variable angle excitation from adiabatic plane-rotation pulses.
    Hendrich K; Garwood M; Merkle H; Uğurbil K
    Magn Reson Med; 1991 Jun; 19(2):496-501. PubMed ID: 1881339
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Optimization of sparse phase encodings for variable repetition-delay turbo-spin echo (TSE) T
    Lee D; Han S; Cho H
    J Magn Reson; 2017 Jan; 274():57-64. PubMed ID: 27886558
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.