These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 34314046)

  • 1. Pedicle screws implantation in polymethylmethacrylate construct to stabilise sixth lumbar vertebral body fracture in dogs: 5 cases (2015-2018).
    Gougeon E; Meheust P
    J Small Anim Pract; 2021 Nov; 62(11):1007-1015. PubMed ID: 34314046
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Treatment of osteoporotic vertebral compression fractures with PMMA-augmented pedicle screw fixation].
    Padányi Csaba ; Misik F; Papp Z; Vitanovics D; Balogh A; Veres R; Lipóth L; Banczerowski P
    Ideggyogy Sz; 2015 Jan; 68(1-2):52-8. PubMed ID: 25842917
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical and radiological results 6 years after treatment of traumatic thoracolumbar burst fractures with pedicle screw instrumentation and balloon assisted endplate reduction.
    Verlaan JJ; Somers I; Dhert WJ; Oner FC
    Spine J; 2015 Jun; 15(6):1172-8. PubMed ID: 24321130
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients.
    Wu ZX; Gao MX; Sang HX; Ma ZS; Cui G; Zhang Y; Lei W
    J Surg Res; 2012 Mar; 173(1):91-8. PubMed ID: 21067776
    [TBL] [Abstract][Full Text] [Related]  

  • 5. EMG-Guided Percutaneous Placement of Cement-Augmented Pedicle Screws for Osteoporotic Thoracolumbar Burst Fractures.
    Iacopino DG; Certo F; Graziano F; Basile L; Gulì C; Visocchi M; Conti A; Maugeri R
    Acta Neurochir Suppl; 2017; 124():319-325. PubMed ID: 28120091
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Augmented posterior instrumentation for the treatment of osteoporotic vertebral body fractures].
    Krappinger D; Kastenberger TJ; Schmid R
    Oper Orthop Traumatol; 2012 Feb; 24(1):4-12. PubMed ID: 22297474
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application of Cement-Injectable Cannulated Pedicle Screw in Treatment of Osteoporotic Thoracolumbar Vertebral Compression Fracture (AO Type A): A Retrospective Study of 28 Cases.
    Rong Z; Zhang F; Xiao J; Wang Z; Luo F; Zhang Z; Xu J; Dai F
    World Neurosurg; 2018 Dec; 120():e247-e258. PubMed ID: 30149154
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Pedicle screw fixation of thoracic spine fractures].
    Božík M; Magala M; Heger T; Matejička D; Baka J; Šimko P
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):140-51. PubMed ID: 25105789
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proximal instrumented vertebral body chance fracture after pedicle screw instrumentation in a thoracic kyphosis patient with osteoporosis.
    Hu X; Lieberman IH
    J Spinal Disord Tech; 2015 Feb; 28(1):31-6. PubMed ID: 22820283
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience.
    Afzal S; Akbar S; Dhar SA
    Eur Spine J; 2008 Mar; 17(3):336-341. PubMed ID: 18193300
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body.
    Hu MH; Wu HT; Chang MC; Yu WK; Wang ST; Liu CL
    Eur Spine J; 2011 Aug; 20(8):1281-8. PubMed ID: 21533852
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of Long Segmental Dorsal Stabilization with Complete Versus Restricted Pedicle Screw Cement Augmentation in Unstable Osteoporotic Midthoracic Vertebral Body Fractures: A Biomechanical Study.
    Spiegl UJ; Weidling M; Schleifenbaum S; Reinhardt M; Heyde CE
    World Neurosurg; 2020 Nov; 143():e541-e549. PubMed ID: 32777399
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surgical treatment of degenerative and traumatic spinal diseases with expandable screws in patients with osteoporosis: 2-year follow-up clinical study.
    Gazzeri R; Roperto R; Fiore C
    J Neurosurg Spine; 2016 Nov; 25(5):610-619. PubMed ID: 27314551
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of pedicle screw misplacement following open vs. percutaneous dorsal instrumentation after traumatic spinal fracture.
    Kreinest M; Rillig J; Küffer M; Grützner PA; Tinelli M; Matschke S
    Eur J Trauma Emerg Surg; 2021 Jun; 47(3):727-732. PubMed ID: 31624857
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical outcomes of 20 brachycephalic dogs with thoracolumbar spinal deformities causing neurological signs treated with spinal stabilization using 3D-printed patient-specific drill guides.
    Violini F; Elford JH; Cardy TJA; Oxley B; Craig A; Behr S
    Vet Surg; 2024 May; 53(4):648-658. PubMed ID: 38532254
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.
    Beck M; Mittlmeier T; Gierer P; Harms C; Gradl G
    Eur Spine J; 2009 Oct; 18(10):1469-77. PubMed ID: 19513764
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Different pedicle osteosynthesis for thoracolumbar vertebral fractures in elderly patients.
    Girardo M; Rava A; Fusini F; Gargiulo G; Coniglio A; Cinnella P
    Eur Spine J; 2018 Jun; 27(Suppl 2):198-205. PubMed ID: 29761236
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Less invasive reduction and fusion of fresh A2 and A 3 traumatic L 1-L 4 fractures with a novel vertebral body augmentation implant and short pedicle screw fixation and fusion.
    Korovessis P; Vardakastanis K; Repantis T; Vitsas V
    Eur J Orthop Surg Traumatol; 2014 Apr; 24(3):297-304. PubMed ID: 24170266
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Pedicle screw at the fracture level and vertebroplasty via paraspinal approach for the treatment of old thoracolumbar fractures].
    He SQ; Dai MH; Huang YJ; Tang XJ; Peng MX; Lin LX; Tang CX
    Zhongguo Gu Shang; 2012 Dec; 25(12):997-1001. PubMed ID: 23627145
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pedicle screw fixation in thoracolumbar and lumbar spine assisted by lateral fluoroscopic imaging: a study to evaluate the accuracy of screw placement.
    Mohanty SP; Bhat SN; Pai Kanhangad M; Gosal GS
    Musculoskelet Surg; 2018 Apr; 102(1):47-55. PubMed ID: 28801863
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.