BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 34324084)

  • 21. A quantitative analysis of metal artifact reduction algorithm performance in volume correction with 3 CBCT devices.
    de Faria Vasconcelos K; Queiroz PM; Codari M; Pinheiro Nicolielo LF; Freitas DQ; Jacobs R; Haiter-Neto F
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2020 Sep; 130(3):328-335. PubMed ID: 32439517
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of the efficacy of a metal artifact reduction algorithm in different cone beam computed tomography scanning parameters.
    Queiroz PM; Groppo FC; Oliveira ML; Haiter-Neto F; Freitas DQ
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2017 Jun; 123(6):729-734. PubMed ID: 28412235
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Artifact expression of polyetheretherketone in cone beam computed tomography: An in vitro study.
    Köse TE; Günaçar DN; Ateş SM; Çağlar İ
    J Prosthet Dent; 2021 Dec; 126(6):793.e1-793.e5. PubMed ID: 34674841
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Measurement Accuracy in Cone Beam Computed Tomography in the Presence of Metal Artifact.
    Ismail A; Lakschevitz F; MacDonald D; Ford NL
    Int J Oral Maxillofac Implants; 2022; 37(1):143-152. PubMed ID: 35235633
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Combined Use of 2 Cone-beam Computed Tomography Scans in the Assessment of Vertical Root Fracture in Teeth with Intracanal Material.
    Wanderley VA; Nascimento EHL; Gaêta-Araujo H; Oliveira-Santos C; Freitas DQ; Oliveira ML
    J Endod; 2021 Jul; 47(7):1132-1137. PubMed ID: 33862106
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assessment of the Influence of Different Intracanal Materials on the Detection of Root Fracture in Birooted Teeth by Cone-beam Computed Tomography.
    Marinho Vieira LE; Diniz de Lima E; Peixoto LR; Oliveira Pinto MG; Sousa Melo SL; Oliveira ML; Rovaris Silva K; Bento PM; Pita de Melo D
    J Endod; 2020 Feb; 46(2):264-270. PubMed ID: 31812360
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of Cone-beam Computed Tomography Artifacts Produced by Metal Objects Located Within and Outside the Field of View.
    Kassabji A; Tahmasbi M; Augsburger RA; Nair M; Kesterke MJ; Jalali P
    J Endod; 2022 Feb; 48(2):249-254. PubMed ID: 34890593
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Influence of the Intracanal Material and Metal Artifact Reduction Tool in the Detection of the Second Mesiobuccal Canal in Cone-beam Computed Tomographic Examinations.
    Rosado LPL; Fagundes FB; Freitas DQ; Oliveira ML; Neves FS
    J Endod; 2020 Aug; 46(8):1067-1073. PubMed ID: 32437789
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Influence of scan mode (partial/full rotations) and FOV size in the formation of artefacts in cone beam CT.
    Costa EDD; Queiroz PM; Santaella GM; Capelozza ALA; Ambrosano GMB; Freitas DQ
    Dentomaxillofac Radiol; 2019 May; 48(4):20180340. PubMed ID: 30563362
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Influence of Intracanal Materials in Vertical Root Fracture Pathway Detection with Cone-beam Computed Tomography.
    Dutra KL; Pachêco-Pereira C; Bortoluzzi EA; Flores-Mir C; Lagravère MO; Corrêa M
    J Endod; 2017 Jul; 43(7):1170-1175. PubMed ID: 28527853
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of the dosimetry and centralization of scout-view function in CBCT.
    Vilela DDS; Manhães Júnior LRC; Nascimento MDCC; Oenning ACC; Junqueira JLC; Martinez EF
    Braz Dent J; 2022; 33(4):31-39. PubMed ID: 36043566
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Artifacts caused by titanium implants in CBCT images of the mandible: an experimental study.
    Fardim KAC; Machado AH; Assis NMSP; Sotto-Maior BS; Mauad LQ; Devito KL
    Gen Dent; 2022; 70(1):72-77. PubMed ID: 34978995
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Performance of a Zirconium-based Root Filling Material with Artifact Reduction Properties in the Detection of Artificially Induced Root Fractures Using Cone-beam Computed Tomographic Imaging.
    Fox A; Basrani B; Lam EWN
    J Endod; 2018 May; 44(5):828-833. PubMed ID: 29580723
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Quantification of metal artifacts on cone beam computed tomography images.
    Pauwels R; Stamatakis H; Bosmans H; Bogaerts R; Jacobs R; Horner K; Tsiklakis K;
    Clin Oral Implants Res; 2013 Aug; 24 Suppl A100():94-9. PubMed ID: 22168574
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of cone-beam computed tomography in the diagnosis of vertical root fractures: the influence of imaging modes and root canal materials.
    Neves FS; Freitas DQ; Campos PS; Ekestubbe A; Lofthag-Hansen S
    J Endod; 2014 Oct; 40(10):1530-6. PubMed ID: 25127934
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of exposure parameters and gutta-percha cone size on fracture-like artifacts in endodontically treated teeth on cone-beam computed tomography images.
    Iikubo M; Kagawa T; Fujisawa J; Kumasaka A; Nishioka T; Kojima I; Sakamoto M; Kobayashi K; Yuasa K
    Oral Radiol; 2020 Oct; 36(4):344-348. PubMed ID: 31583602
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Application of an auto-edge counting method for quantification of metal artifacts in CBCT images: a multivariate analysis of object position, field of view size, tube voltage, and metal artifact reduction algorithm.
    Khosravifard A; Saberi BV; Khosravifard N; Motallebi S; Kajan ZD; Ghaffari ME
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2021 Dec; 132(6):735-743. PubMed ID: 33975812
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth.
    Bechara B; McMahan CA; Noujeim M; Faddoul T; Moore WS; Teixeira FB; Geha H
    Dentomaxillofac Radiol; 2013; 42(7):20120404. PubMed ID: 23625067
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Characterization of Scattered X-Ray Photons in Dental Cone-Beam Computed Tomography.
    Yang CC
    PLoS One; 2016; 11(3):e0149904. PubMed ID: 26950435
    [TBL] [Abstract][Full Text] [Related]  

  • 40. CBCT image artefacts generated by implants located inside the field of view or in the exomass.
    Demirturk Kocasarac H; Koenig LJ; Ustaoglu G; Oliveira ML; Freitas DQ
    Dentomaxillofac Radiol; 2022 Feb; 51(2):20210092. PubMed ID: 34289314
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]