These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 34338658)

  • 21. Trapped rotablation wire causing longitudinal stent deformation.
    Lempereur M; Bogale N; Fung A
    Can J Cardiol; 2014 Jan; 30(1):146.e5-7. PubMed ID: 24365197
    [TBL] [Abstract][Full Text] [Related]  

  • 22. One-year optical coherence tomography findings in patients with late and very-late stent thrombosis treated with intravascular imaging guided percutaneous coronary intervention.
    Ñato M; Gomez-Lara J; Romaguera R; Roura G; Ferreiro JL; Teruel L; Gracida M; Fuentes L; Vandeloo B; Gomez-Hospital JA; Cequier A
    Int J Cardiovasc Imaging; 2018 Oct; 34(10):1511-1520. PubMed ID: 29790037
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optical coherence tomography findings after longitudinal ablation for an underexpanded stent in a heavily calcified lesion: a case report.
    Koide M; Inoue K; Matsuo A; Fujita H
    BMC Cardiovasc Disord; 2016 Nov; 16(1):241. PubMed ID: 27894264
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In-Stent Catheter-Induced Neointimal Dissection Assessed by Optical Coherence Tomography.
    Ohmure K; Yoshino S; Fukumoto D; Shimono H; Tabata H; Uchikado Y; Tateishi S; Ohishi M
    JACC Cardiovasc Interv; 2017 Jul; 10(14):1462-1463. PubMed ID: 28668313
    [No Abstract]   [Full Text] [Related]  

  • 25. Unusual stent fracture: diagnosis with optical coherence tomography.
    Bennett J; De Cock D; Hiltrop N; Adriaenssens T
    J Cardiovasc Med (Hagerstown); 2016 Dec; 17 Suppl 2():e231-e232. PubMed ID: 25226340
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Longitudinal stent elongation during retraction of entrapped jailed guidewire in a side branch with balloon catheter support: a case report.
    Taniguchi N; Mizuguchi Y; Takahashi A
    Cardiovasc Revasc Med; 2015; 16(1):52-4. PubMed ID: 24972514
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mini- versus classical kissing balloon inflation in provisional technique for bifurcation intervention.
    Liu J; Chen S; Wei J; Zeng F; Li L
    J Interv Cardiol; 2018 Dec; 31(6):755-764. PubMed ID: 30069984
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Classification of mechanisms of strut malapposition after angiographically optimized stent implantation: An optical coherence tomography study.
    Agrawal M; Hakeem A; Ahmed Z; Uretsky BF
    Catheter Cardiovasc Interv; 2017 Aug; 90(2):225-232. PubMed ID: 28805036
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Longitudinal stent deformation as a cause of very late stent thrombosis: Optical coherence tomography images.
    Kobayashi N; Hata N; Okazaki H; Shimizu W
    Int J Cardiol; 2016 Jan; 202():601-3. PubMed ID: 26447670
    [No Abstract]   [Full Text] [Related]  

  • 30. Subintimal Crush of an Occluded Stent to Recanalize a Chronic Total Occlusion Due to In-Stent Restenosis: Insights From a Multimodality Imaging Approach.
    Capretti G; Mitomo S; Giglio M; Carlino M; Colombo A; Azzalini L
    JACC Cardiovasc Interv; 2017 Apr; 10(8):e81-e83. PubMed ID: 28365267
    [No Abstract]   [Full Text] [Related]  

  • 31. Neointima and neoatherosclerotic characteristics in bare metal and first- and second-generation drug-eluting stents in patients admitted with cardiovascular events attributed to stent failure: an optical coherence tomography study.
    Stettler R; Dijkstra J; Räber L; Torii R; Zhang YJ; Karanasos A; Lui S; Crake T; Hamshere S; Garcia-Garcia HM; Tenekecioglu E; Ozkor M; Windecker S; Serruys PW; Regar E; Mathur A; Bourantas CV
    EuroIntervention; 2018 Feb; 13(15):e1831-e1840. PubMed ID: 28606888
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implantation: predisposing mechanical properties, incidence, and predictors in a large patient cohort.
    Leibundgut G; Gick M; Toma A; Valina C; Löffelhardt N; Büttner HJ; Neumann FJ
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):E206-14. PubMed ID: 22581708
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials.
    Alsidawi S; Effat M; Rahman S; Abdallah M; Leesar M
    Cardiovasc Ther; 2015 Dec; 33(6):360-6. PubMed ID: 26363283
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Longitudinal stent deformation during coronary bifurcation stenting.
    Vijayvergiya R; Sharma P; Gupta A; Goyal P; Panda P
    Cardiovasc Revasc Med; 2016 Mar; 17(2):143-5. PubMed ID: 26811144
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Role of Optical Coherence Tomography in the Assessment of Stent Deformation.
    Abdel-Hadi H; Shah AH; Džavík V
    Can J Cardiol; 2016 Mar; 32(3):396.e1-2. PubMed ID: 26921163
    [No Abstract]   [Full Text] [Related]  

  • 36. Minimally invasive atherectomy with a virtual 3-Fr sheathless guiding catheter and a 0.9-mm excimer laser catheter for the treatment of coronary in-stent restenosis: a case report.
    Hashimoto S; Takahashi A; Mizuguchi Y; Yamada T; Taniguchi N; Hata T
    Cardiovasc Interv Ther; 2016 Oct; 31(4):296-9. PubMed ID: 26410846
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium).
    Joner M; Koppara T; Byrne RA; Castellanos MI; Lewerich J; Novotny J; Guagliumi G; Xhepa E; Adriaenssens T; Godschalk TC; Malik N; Alfonso F; Tada T; Neumann FJ; Desmet W; Ten Berg JM; Gershlick AH; Feldman LJ; Massberg S; Kastrati A;
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1340-1350. PubMed ID: 30025727
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Multiple Mechanisms in 1 In-Stent Restenosis Assessed by Optical Coherence Tomography.
    Lu WD; Huang CW; Li YH; Chen JY
    JACC Cardiovasc Interv; 2017 Nov; 10(22):2340-2341. PubMed ID: 29102578
    [No Abstract]   [Full Text] [Related]  

  • 39. Unravelment of Medtronic Onyx stent during bifurcation stenting using the jailed wire technique; An adverse effect of helical stent structure?
    Leenders GE; Liew HB; Stella PR
    Cardiovasc Revasc Med; 2018 Dec; 19(8S):58-59. PubMed ID: 30115559
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Coronary wire entrapment and unintended extraction of a just deployed stent].
    Talanas G; Siciliano R; Canonico ME; Parodi G
    G Ital Cardiol (Rome); 2020 Nov; 21(11 Suppl 1):58S-59S. PubMed ID: 33295336
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.