BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

373 related articles for article (PubMed ID: 34338842)

  • 21. Leaflet thrombosis following transcatheter aortic valve implantation.
    Marwan M; Mekkhala N; Göller M; Röther J; Bittner D; Schuhbaeck A; Hell M; Muschiol G; Kolwelter J; Feyrer R; Schlundt C; Achenbach S; Arnold M
    J Cardiovasc Comput Tomogr; 2018; 12(1):8-13. PubMed ID: 29195844
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Feasibility of Non-Invasive Coronary Artery Disease Screening with Coronary CT Angiography before Transcatheter Aortic Valve Implantation.
    Boyer J; Bartoli A; Deharo P; Vaillier A; Ferrara J; Barral PA; Jaussaud N; Morera P; Porto A; Collart F; Jacquier A; Cuisset T
    J Clin Med; 2023 Mar; 12(6):. PubMed ID: 36983286
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease.
    Harris BS; De Cecco CN; Schoepf UJ; Steinberg DH; Bayer RR; Krazinski AW; Dyer KT; Sandhu MK; Zile MR; Meinel FG
    Radiology; 2015 Apr; 275(1):80-8. PubMed ID: 25393848
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Combined Coronary CT Angiography and Evaluation of Access Vessels for TAVR Patients in Free-Breathing with Single Contrast Medium Injection Using a 16-cm-Wide Detector CT.
    Shuai T; Li W; You Y; Deng L; Li J; Peng L; Li Z
    Acad Radiol; 2021 Dec; 28(12):1662-1668. PubMed ID: 32859475
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Combined cCTA and TAVR Planning for Ruling Out Significant CAD: Added Value of ML-Based CT-FFR.
    Gohmann RF; Pawelka K; Seitz P; Majunke N; Heiser L; Renatus K; Desch S; Lauten P; Holzhey D; Noack T; Wilde J; Kiefer P; Krieghoff C; Lücke C; Gottschling S; Ebel S; Borger MA; Thiele H; Panknin C; Horn M; Abdel-Wahab M; Gutberlet M
    JACC Cardiovasc Imaging; 2022 Mar; 15(3):476-486. PubMed ID: 34801449
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Feasibility of ultra-low contrast 64-slice computed tomography angiography before transcatheter aortic valve implantation: a real-world experience.
    Spagnolo P; Giglio M; Di Marco D; Latib A; Besana F; Chieffo A; Montorfano M; Sironi S; Alfieri O; Colombo A
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):24-33. PubMed ID: 26160397
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Value of CT signs and measurements as a predictor of pulmonary hypertension and mortality in symptomatic severe aortic valve stenosis.
    Eberhard M; Mastalerz M; Pavicevic J; Frauenfelder T; Nietlispach F; Maisano F; Tanner FC; Nguyen-Kim TDL
    Int J Cardiovasc Imaging; 2017 Oct; 33(10):1637-1651. PubMed ID: 28550588
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Atrial Fibrillation: Diagnostic Accuracy of Coronary CT Angiography Performed with a Whole-Heart 230-µm Spatial Resolution CT Scanner.
    Andreini D; Pontone G; Mushtaq S; Conte E; Perchinunno M; Guglielmo M; Volpato V; Annoni A; Baggiano A; Formenti A; Mancini ME; Beltrama V; Ditali V; Campari A; Fiorentini C; Bartorelli AL; Pepi M
    Radiology; 2017 Sep; 284(3):676-684. PubMed ID: 28445682
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: Comparison of systolic high-pitch vs. multiphasic data acquisition.
    Capilli F; Benndorf M; Soschynski M; Hagar MT; Kharabish A; Neumann FJ; Pache G; Schlett CL; Bamberg F; Krauss T
    Eur J Radiol; 2020 Dec; 133():109366. PubMed ID: 33166834
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The role of computed tomography in the planning of transcatheter aortic valve implantation: a retrospective analysis in 200 procedures.
    Chiocchi M; Forcina M; Morosetti D; Pugliese L; Cavallo AU; Citraro D; De Stasio V; Presicce M; Floris R; Romeo F
    J Cardiovasc Med (Hagerstown); 2018 Oct; 19(10):571-578. PubMed ID: 30015782
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Coronary CT angiography in patients with atrial fibrillation: Standard-dose and low-dose imaging with a high-resolution whole-heart CT scanner.
    Matveeva A; Schmitt RR; Edtinger K; Wagner M; Kerber S; Deneke T; Uder M; Barth S
    Eur Radiol; 2018 Aug; 28(8):3432-3440. PubMed ID: 29426987
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.
    Wuest W; Anders K; Schuhbaeck A; May MS; Gauss S; Marwan M; Arnold M; Ensminger S; Muschiol G; Daniel WG; Uder M; Achenbach S
    Eur Radiol; 2012 Jan; 22(1):51-8. PubMed ID: 21845463
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Computed tomography predictors of mortality, stroke and conduction disturbances in women undergoing TAVR: A sub-analysis of the WIN-TAVI registry.
    Spaziano M; Chieffo A; Watanabe Y; Chandrasekhar J; Sartori S; Lefèvre T; Petronio AS; Presbitero P; Tchetche D; Iadanza A; Van Mieghem NM; Mehilli J; Mehran R; Morice MC;
    J Cardiovasc Comput Tomogr; 2018; 12(4):338-343. PubMed ID: 29735255
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation.
    Meier D; Depierre A; Topolsky A; Roguelov C; Dupré M; Rubimbura V; Eeckhout E; Qanadli SD; Muller O; Mahendiran T; Rotzinger D; Fournier S
    J Cardiovasc Transl Res; 2021 Oct; 14(5):894-901. PubMed ID: 33543417
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR.
    Shnayien S; Beetz NL; Bressem KK; Hamm B; Niehues SM
    Rofo; 2023 Feb; 195(2):139-147. PubMed ID: 36063835
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Influence of coronary artery disease and percutaneous coronary intervention on mid-term outcomes in patients with aortic valve stenosis treated with transcatheter aortic valve implantation.
    Kaihara T; Higuma T; Izumo M; Kotoku N; Suzuki T; Kameshima H; Sato Y; Kuwata S; Koga M; Mitarai T; Watanabe M; Okuyama K; Kamijima R; Ishibashi Y; Yoneyama K; Tanabe Y; Harada T; Akashi YJ
    Clin Cardiol; 2021 Aug; 44(8):1089-1097. PubMed ID: 34033124
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Predictors of All-Cause Mortality After Successful Transcatheter Aortic Valve Implantation in Patients With Atrial Fibrillation.
    Yamamoto M; Hayashida K; Hengstenberg C; Watanabe Y; Van Mieghem NM; Jin J; Saito S; Valgimigli M; Nicolas J; Mehran R; Moreno R; Kimura T; Chen C; Unverdorben M; Dangas GD
    Am J Cardiol; 2023 Nov; 207():150-158. PubMed ID: 37741105
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Combined Coronary CT-Angiography and TAVI Planning: Utility of CT-FFR in Patients with Morphologically Ruled-Out Obstructive Coronary Artery Disease.
    Gohmann RF; Seitz P; Pawelka K; Majunke N; Schug A; Heiser L; Renatus K; Desch S; Lauten P; Holzhey D; Noack T; Wilde J; Kiefer P; Krieghoff C; Lücke C; Ebel S; Gottschling S; Borger MA; Thiele H; Panknin C; Abdel-Wahab M; Horn M; Gutberlet M
    J Clin Med; 2022 Feb; 11(5):. PubMed ID: 35268422
    [No Abstract]   [Full Text] [Related]  

  • 39. Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure.
    Talei Franzesi CR; Ippolito D; Riva L; Fior D; Cangiotti C; Sironi S
    Br J Radiol; 2018 Dec; 91(1092):20170802. PubMed ID: 30074831
    [TBL] [Abstract][Full Text] [Related]  

  • 40. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure.
    Mangold S; De Cecco CN; Schoepf UJ; Kuhlman TS; Varga-Szemes A; Caruso D; Duguay TM; Tesche C; Vogl TJ; Nikolaou K; Steinberg DH; Wichmann JL
    Eur J Radiol; 2017 Jan; 86():276-283. PubMed ID: 28027760
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.