These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 34338939)

  • 1. Anatomical characteristics of the membranous septum are predictive of pacemaker requirement in patients undergoing transcatheter aortic valve replacement.
    Na J; Nixon B; Childress J; Han P; Norcross G; Liskov S; Jeudy J; Jimenez Restrepo A
    J Interv Card Electrophysiol; 2022 Mar; 63(2):449-459. PubMed ID: 34338939
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement.
    Chen YH; Chang HH; Liao TW; Leu HB; Chen IM; Chen PL; Lin SM
    J Thorac Cardiovasc Surg; 2022 Jul; 164(1):42-51.e2. PubMed ID: 32891451
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computed tomography (CT) assessment of the membranous septal anatomy prior to transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 valve.
    Oestreich BA; Mbai M; Gurevich S; Nijjar PS; Adabag S; Bertog S; Kelly R; Garcia S
    Cardiovasc Revasc Med; 2018; 19(5 Pt B):626-631. PubMed ID: 29352699
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.
    Maeno Y; Abramowitz Y; Kawamori H; Kazuno Y; Kubo S; Takahashi N; Mangat G; Okuyama K; Kashif M; Chakravarty T; Nakamura M; Cheng W; Friedman J; Berman D; Makkar RR; Jilaihawi H
    JACC Cardiovasc Imaging; 2017 Oct; 10(10 Pt A):1139-1147. PubMed ID: 28412434
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry.
    Hokken TW; Muhemin M; Okuno T; Veulemans V; Lopes BB; Beneduce A; Vittorio R; Ooms JF; Adrichem R; Neleman T; Kardys I; Daemen J; Chieffo A; Montorfano M; Cavalcante J; Zeus T; Pilgrim T; Toggweiler S; Van Mieghem NM
    J Cardiovasc Comput Tomogr; 2022; 16(6):524-530. PubMed ID: 35872136
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement.
    Jilaihawi H; Zhao Z; Du R; Staniloae C; Saric M; Neuburger PJ; Querijero M; Vainrib A; Hisamoto K; Ibrahim H; Collins T; Clark E; Pushkar I; Bamira D; Benenstein R; Tariq A; Williams M
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1796-1807. PubMed ID: 31473236
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A computational framework for post-TAVR cardiac conduction abnormality (CCA) risk assessment in patient-specific anatomy.
    Reza S; Bianchi M; Kovarovic B; Anam S; Slepian MJ; Hamdan A; Haj-Ali R; Bluestein D
    Artif Organs; 2022 Jul; 46(7):1305-1317. PubMed ID: 35083748
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.
    Hamdan A; Guetta V; Klempfner R; Konen E; Raanani E; Glikson M; Goitein O; Segev A; Barbash I; Fefer P; Spiegelstein D; Goldenberg I; Schwammenthal E
    JACC Cardiovasc Interv; 2015 Aug; 8(9):1218-1228. PubMed ID: 26292585
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Short membranous septum length in bicuspid aortic valve stenosis increases the risk of conduction disturbances.
    Hamdan A; Nassar M; Schwammenthal E; Perlman G; Arow Z; Lessick J; Kerner A; Barsheshet A; Assa HV; Assali A; Aviv Y; Goitein O; Brodov Y; Codner P; Orvin K; Biton D; Klein E; Danenberg H; Finkelstein A; Kornowski R
    J Cardiovasc Comput Tomogr; 2021; 15(4):339-347. PubMed ID: 33153946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
    Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing Care of Patients With Right Bundle Branch Block Undergoing Transcatheter Aortic Valve Replacement.
    Kassier A; Velagapudi P; Shrestha NM; Schuitema J; Gauri A; Frost J; Merhi W; Jovinge S; Chalfoun N
    Cardiovasc Revasc Med; 2022 Sep; 42():17-25. PubMed ID: 35398009
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of reliability and predictivity of membrane septum length measurements for pacemaker need after transcatheter aortic valve replacement.
    Hioki H; Watanabe Y; Kozuma K; Ryuzaki T; Goto S; Inohara T; Katsumata Y; Tsunaki T; Kawahata R; Kobayashi T; Asami M; Otsuka T; Yamamoto M; Hayashida K;
    Catheter Cardiovasc Interv; 2022 Nov; 100(5):868-876. PubMed ID: 36073020
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement.
    Chamandi C; Barbanti M; Munoz-Garcia A; Latib A; Nombela-Franco L; Gutiérrez-Ibanez E; Veiga-Fernandez G; Cheema AN; Cruz-Gonzalez I; Serra V; Tamburino C; Mangieri A; Colombo A; Jiménez-Quevedo P; Elizaga J; Laughlin G; Lee DH; Garcia Del Blanco B; Rodriguez-Gabella T; Marsal JR; Côté M; Philippon F; Rodés-Cabau J
    JACC Cardiovasc Interv; 2018 Feb; 11(3):301-310. PubMed ID: 29413244
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis.
    Miyashita H; Moriyama N; Yamanaka F; Saito S; Lehtola H; Piuhola J; Niemelä M; Laine M
    J Cardiovasc Electrophysiol; 2022 Jul; 33(7):1576-1586. PubMed ID: 35543515
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Utility of rapid atrial pacing before and after TAVR with balloon-expandable valve in  predicting permanent pacemaker implantation.
    Tan BE; Hashem A; Boppana LKT; Mohamed MS; Abbas SF; Faisaluddin M; Thakkar S; Ahmed AK; Hall C; Abtahian F; Rao M; Bhatt DL; Depta JP
    Catheter Cardiovasc Interv; 2023 Nov; 102(5):919-928. PubMed ID: 37698294
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prediction of conduction disturbances in patients undergoing transcatheter aortic valve replacement.
    Pavlicek V; Mahfoud F; Bubel K; Fries P; Ewen S; Böhm M; Scheller B; Ukena C
    Clin Res Cardiol; 2023 May; 112(5):677-690. PubMed ID: 36680617
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Importance of Preoperative Computed Tomography Assessment of the Membranous Septal Anatomy in Patients Undergoing Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve.
    Miki T; Senoo K; Ohkura T; Kadoya Y; Ito N; Kuwabara K; Nakanishi N; Zen K; Nakamura T; Yamano T; Shiraishi H; Shirayama T; Matoba S
    Circ J; 2020 Jan; 84(2):269-276. PubMed ID: 31902829
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term pacemaker dependency and impact of pacing on mortality following transcatheter aortic valve replacement with the LOTUS valve.
    Alasti M; Rashid H; Rangasamy K; Kotschet E; Adam D; Alison J; Gooley R; Zaman S
    Catheter Cardiovasc Interv; 2018 Oct; 92(4):777-782. PubMed ID: 29314625
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.