These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
221 related articles for article (PubMed ID: 34339667)
1. Safety and efficacy of a novel electrocautery-enhanced lumen-apposing metal stent in interventional EUS procedures (with video). Mangiavillano B; Moon JH; Crinò SF; Larghi A; Pham KD; Teoh AYB; Paduano D; Lee YN; Yoo HW; Shin IS; Rizzatti G; Robles-Medranda C; Oleas R; Conti Bellocchi MC; Auriemma F; Lamonaca L; Spatola F; Conigliaro R; Facciorusso A; Gabbrielli A; Repici A Gastrointest Endosc; 2022 Jan; 95(1):115-122. PubMed ID: 34339667 [TBL] [Abstract][Full Text] [Related]
2. Indirect comparison of various lumen-apposing metal stents for EUS-guided biliary and gallbladder drainage: a systematic review and meta-analysis. Singh S; Suresh Kumar VC; Aswath G; Akbar Khan HM; Sapkota B; Vinayek R; Dutta S; Dahiya DS; Inamdar S; Mohan BP; Sharma N; Adler DG Gastrointest Endosc; 2024 Nov; 100(5):829-839.e3. PubMed ID: 38851453 [TBL] [Abstract][Full Text] [Related]
3. EUS-guided gastroenterostomy using a novel electrocautery lumen apposing metal stent for treatment of gastric outlet obstruction (with video). Mangiavillano B; Larghi A; Vargas-Madrigal J; Facciorusso A; Di Matteo F; Crinò SF; Pham KD; Moon JH; Auriemma F; Camellini L; Paduano D; Stigliano S; Calabrese F; Ofosu A; Al-Lehibi A; Repici A Dig Liver Dis; 2023 May; 55(5):644-648. PubMed ID: 36890050 [TBL] [Abstract][Full Text] [Related]
4. Endoscopic ultrasound-guided gallbladder drainage as a first approach for jaundice palliation in unresectable malignant distal biliary obstruction: Prospective study. Mangiavillano B; Moon JH; Facciorusso A; Vargas-Madrigal J; Di Matteo F; Rizzatti G; De Luca L; Forti E; Mutignani M; Al-Lehibi A; Paduano D; Bulajic M; Decembrino F; Auriemma F; Franchellucci G; De Marco A; Gentile C; Shin IS; Rea R; Massidda M; Calabrese F; Mirante VG; Ofosu A; Crinò SF; Hassan C; Repici A; Larghi A Dig Endosc; 2024 Mar; 36(3):351-358. PubMed ID: 37253185 [TBL] [Abstract][Full Text] [Related]
5. Lumen-apposing metal stents for malignant biliary obstruction: Is this the ultimate horizon of our experience? Anderloni A; Troncone E; Fugazza A; Cappello A; Del Vecchio Blanco G; Monteleone G; Repici A World J Gastroenterol; 2019 Aug; 25(29):3857-3869. PubMed ID: 31413524 [TBL] [Abstract][Full Text] [Related]
6. EUS-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing metal stents in patients with malignant distal biliary obstruction: multicenter collaboration from the United Kingdom and Ireland. On W; Paranandi B; Smith AM; Venkatachalapathy SV; James MW; Aithal GP; Varbobitis I; Cheriyan D; McDonald C; Leeds JS; Nayar MK; Oppong KW; Geraghty J; Devlin J; Ahmed W; Scott R; Wong T; Huggett MT Gastrointest Endosc; 2022 Mar; 95(3):432-442. PubMed ID: 34637805 [TBL] [Abstract][Full Text] [Related]
7. EUS-Guided Choledochoduodenostomy for Distal Malignant Biliary Obstruction Using Electrocautery-Enhanced Lumen-Apposing Metal Stents: First US, Multicenter Experience. El Chafic AH; Shah JN; Hamerski C; Binmoeller KF; Irani S; James TW; Baron TH; Nieto J; Romero RV; Evans JA; Kahaleh M Dig Dis Sci; 2019 Nov; 64(11):3321-3327. PubMed ID: 31175495 [TBL] [Abstract][Full Text] [Related]
8. Lumen apposing metal stents versus tubular self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy in malignant biliary obstruction. de Benito Sanz M; Nájera-Muñoz R; de la Serna-Higuera C; Fuentes-Valenzuela E; Fanjul I; Chavarría C; García-Alonso FJ; Sanchez-Ocana R; Carbajo AY; Bazaga S; Perez-Miranda M Surg Endosc; 2021 Dec; 35(12):6754-6762. PubMed ID: 33258038 [TBL] [Abstract][Full Text] [Related]
9. A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study. Yoo HW; Moon JH; Jo SJ; Lee YN; Park JK; Lee TH; Cha SW; Cho YD; Park SH; Park SI; Jeong S; Lee DH Endoscopy; 2021 Sep; 53(9):922-926. PubMed ID: 33336343 [TBL] [Abstract][Full Text] [Related]
10. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos). Siddiqui AA; Adler DG; Nieto J; Shah JN; Binmoeller KF; Kane S; Yan L; Laique SN; Kowalski T; Loren DE; Taylor LJ; Munigala S; Bhat YM Gastrointest Endosc; 2016 Apr; 83(4):699-707. PubMed ID: 26515956 [TBL] [Abstract][Full Text] [Related]
11. EUS-guided gallbladder drainage in patients with acute cholecystitis and high surgical risk using an electrocautery-enhanced lumen-apposing metal stent device. Dollhopf M; Larghi A; Will U; Rimbaş M; Anderloni A; Sanchez-Yague A; Teoh AYB; Kunda R Gastrointest Endosc; 2017 Oct; 86(4):636-643. PubMed ID: 28259594 [TBL] [Abstract][Full Text] [Related]
12. Comparison of the effectiveness and safety of lumen-apposing metal stents and anti-migrating tubular self-expandable metal stents for EUS-guided gallbladder drainage in high surgical risk patients with acute cholecystitis. Cho SH; Oh D; Song TJ; Park DH; Seo DW; Lee SK; Kim MH; Lee YN; Moon JH; Lee SS Gastrointest Endosc; 2020 Mar; 91(3):543-550. PubMed ID: 31629721 [TBL] [Abstract][Full Text] [Related]
13. Revolutionizing outcomes: endoscopic ultrasound-guided gallbladder drainage using innovative electrocautery enhanced-lumen apposing metal stents for high-risk surgical patients. Chon HK; Lee YC; Kim TH; Lee SO; Kim SH Sci Rep; 2024 Jun; 14(1):12893. PubMed ID: 38839798 [TBL] [Abstract][Full Text] [Related]
14. A novel bipolar electrocautery-enhanced delivery system with a lumen-apposing metal stent for EUS-guided drainage: A porcine study. Jo SJ; Moon JH; Lee YN; Park JK; Lee TH; Park SH; Park SI; Jeong S; Lee DH J Hepatobiliary Pancreat Sci; 2023 Feb; 30(2):263-268. PubMed ID: 35583204 [TBL] [Abstract][Full Text] [Related]
15. EUS-guided choledochoduodenostomy by use of electrocautery-enhanced lumen-apposing metal stents: a French multicenter study after implementation of the technique (with video). Jacques J; Privat J; Pinard F; Fumex F; Chaput U; Valats JC; Cholet F; Jezequel J; Grandval P; Legros R; Lepetit H; Albouys J; Napoleon B Gastrointest Endosc; 2020 Jul; 92(1):134-141. PubMed ID: 32084411 [TBL] [Abstract][Full Text] [Related]
16. Experimental study of a physician-controlled electrocautery-enhanced delivery system incorporating a newly developed lumen-apposing metal stent for interventional endoscopic ultrasound (with videos). Mukai S; Itoi T; Tsuchiya T; Ishii K; Tanaka R; Tonozuka R; Furuichi Y; Joyama E; Miyazawa H; Sofuni A J Hepatobiliary Pancreat Sci; 2022 Jul; 29(7):817-824. PubMed ID: 35030302 [TBL] [Abstract][Full Text] [Related]
17. Endoscopic ultrasound-guided gallbladder drainage with long-term lumen-apposing metal stent indwell: 1-year results from a prospective nationwide observational study. Bazaga S; García-Alonso FJ; Aparicio Tormo JR; Martinez Moreno B; Sanchiz V; Gornals JB; Loras C; Terán Á; Vazquez-Sequeiros E; Pedraza Sanz R; Súbtil JC; Pérez-Millan A; Uceda Porta F; Vila JJ; de la Serna-Higuera C; Couto-Worner I; Guarner-Argente C; Perez-Miranda M; J Gastroenterol Hepatol; 2024 Feb; 39(2):360-368. PubMed ID: 37920889 [TBL] [Abstract][Full Text] [Related]
18. Single-stage EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction. Anderloni A; Fugazza A; Troncone E; Auriemma F; Carrara S; Semeraro R; Maselli R; Di Leo M; D'Amico F; Sethi A; Repici A Gastrointest Endosc; 2019 Jan; 89(1):69-76. PubMed ID: 30189198 [TBL] [Abstract][Full Text] [Related]
19. Comparison of clinical efficacies and safeties of lumen-apposing metal stent and conventional-type metal stent-assisted EUS-guided pancreatic wall-off necrosis drainage: a real-life experience in a tertiary hospital. Law ST; De La SernaHiguera C; Simón PG; Pérez-MirandaCastillo M Surg Endosc; 2018 May; 32(5):2448-2453. PubMed ID: 29101565 [TBL] [Abstract][Full Text] [Related]
20. Feasibility, safety, and outcomes of a single-step endoscopic ultrasonography-guided drainage of pancreatic fluid collections without fluoroscopy using a novel electrocautery-enhanced lumen-apposing, self-expanding metal stent. Yoo J; Yan L; Hasan R; Somalya S; Nieto J; Siddiqui AA Endosc Ultrasound; 2017; 6(2):131-135. PubMed ID: 28440239 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]