These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 34340864)

  • 1. In the Right Place at the Right Time: Growing Evidence for Out-of-Office Blood Pressure Measurement in Hemodialysis Patients.
    Cohen JB
    Am J Kidney Dis; 2021 Nov; 78(5):621-623. PubMed ID: 34340864
    [No Abstract]   [Full Text] [Related]  

  • 2. [Out-of-center blood pressure measurements in dialysis patients: Feasibility and comparison of methods].
    Diawara F; Fumeron C; Duflot L; Tia MW; Bobrie G
    Nephrol Ther; 2022 Apr; 18(2):113-120. PubMed ID: 35144906
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blood pressure and target-organ damage in hemodialysis: but which blood pressure?
    Georgianos PI; Vaios V; Liakopoulos V; Zebekakis PE
    J Hypertens; 2017 Dec; 35(12):2552-2553. PubMed ID: 29095236
    [No Abstract]   [Full Text] [Related]  

  • 4. Blood pressure in hemodialysis: targets?
    Georgianos PI; Agarwal R
    Curr Opin Nephrol Hypertens; 2017 Nov; 26(6):523-529. PubMed ID: 28832356
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparing the frequency of hypertension determined by peri-dialysis measurement and ABPM in hemodialysis patients.
    Abbasi MR; Lessan-Pezeshki M; Najafi MT; Gatmiri SM; Karbakhsh M; Mohebi-Nejad A
    Ren Fail; 2014 Jun; 36(5):682-6. PubMed ID: 24502240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Blood pressure measurement in hemodialysis patients.
    Lazar AE; Smith MC; Rahman M
    Semin Dial; 2004; 17(4):250-4. PubMed ID: 15250912
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Office and 44-hour ambulatory blood pressure and central haemodynamic parameters in the patients with end-stage renal diseases undergoing haemodialysis].
    Trukhanova MA; Orlov AV; Tolkacheva VV; Troitskaya EA; Villevalde SV; Kobalava ZD
    Kardiologiia; 2019 Sep; 59(8S):63-72. PubMed ID: 31526363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hypertension in Chronic Kidney Disease Part 1: Out-of-Office Blood Pressure Monitoring: Methods, Thresholds, and Patterns.
    Parati G; Ochoa JE; Bilo G; Agarwal R; Covic A; Dekker FW; Fliser D; Heine GH; Jager KJ; Gargani L; Kanbay M; Mallamaci F; Massy Z; Ortiz A; Picano E; Rossignol P; Sarafidis P; Sicari R; Vanholder R; Wiecek A; London G; Zoccali C;
    Hypertension; 2016 Jun; 67(6):1093-101. PubMed ID: 27141058
    [No Abstract]   [Full Text] [Related]  

  • 9. Blood pressure measurement in dialysis patients.
    Sankaranarayanan N; Santos SF; Peixoto AJ
    Adv Chronic Kidney Dis; 2004 Apr; 11(2):134-42. PubMed ID: 15216485
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pro: Ambulatory blood pressure should be used in all patients on hemodialysis.
    Agarwal R
    Nephrol Dial Transplant; 2015 Sep; 30(9):1432-7. PubMed ID: 26022728
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Level of blood pressure control in a hypertensive population when measurements are performed outside the clinical setting.
    Félix-Redondo FJ; Fernández-Bergés D; Espinosa-Garcia J; Pozuelos-Estrada J; Molina-Martínez LM; Pérez-Castán JF; Ríos-Rivera J; Valiente-Rubio JI; Gómez-de-la-Cámara A; Rodríguez-Pascual N
    Cardiol J; 2009; 16(1):57-67. PubMed ID: 19130417
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Challenges in blood pressure measurement in patients treated with maintenance hemodialysis.
    Roberts MA; Pilmore HL; Tonkin AM; Garg AX; Pascoe EM; Badve SV; Cass A; Ierino FL; Hawley CM;
    Am J Kidney Dis; 2012 Sep; 60(3):463-72. PubMed ID: 22704141
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relationship between different blood pressure measurements and left ventricular mass by cardiac magnetic resonance imaging in end-stage renal disease.
    Merchant A; Wald R; Goldstein MB; Yuen D; Kirpalani A; Dacouris N; Ray JG; Kiaii M; Leipsic J; Kotha V; Deva D; Yan AT
    J Am Soc Hypertens; 2015 Apr; 9(4):275-84. PubMed ID: 25753299
    [TBL] [Abstract][Full Text] [Related]  

  • 14. When office blood pressure measurement is not enough.
    Barrios V; Escobar C; Echarri R
    Int J Cardiol; 2010 Nov; 145(1):101. PubMed ID: 19524310
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Location not quantity of blood pressure measurements predicts mortality in hemodialysis patients.
    Agarwal R; Andersen MJ; Light RP
    Am J Nephrol; 2008; 28(2):210-7. PubMed ID: 17960059
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Out-of-Office Blood Pressure Monitoring: A Comparison of Ambulatory Blood Pressure Monitoring and Home (Self) Monitoring Of Blood Pressure.
    Townsend RR
    Hypertension; 2020 Dec; 76(6):1667-1673. PubMed ID: 33012202
    [No Abstract]   [Full Text] [Related]  

  • 17. Out-of-hemodialysis-unit blood pressure is a superior determinant of left ventricular hypertrophy.
    Agarwal R; Brim NJ; Mahenthiran J; Andersen MJ; Saha C
    Hypertension; 2006 Jan; 47(1):62-8. PubMed ID: 16344376
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Principles of Blood Pressure Measurement - Current Techniques, Office vs Ambulatory Blood Pressure Measurement.
    Vischer AS; Burkard T
    Adv Exp Med Biol; 2017; 956():85-96. PubMed ID: 27417699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Blood pressure and mortality among hemodialysis patients.
    Agarwal R
    Hypertension; 2010 Mar; 55(3):762-8. PubMed ID: 20083728
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients.
    Agarwal R; Andersen MJ; Bishu K; Saha C
    Kidney Int; 2006 Mar; 69(5):900-6. PubMed ID: 16518349
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.