284 related articles for article (PubMed ID: 34343412)
21. A tool for patient-specific prediction of delivery discrepancies in machine parameters using trajectory log files.
Chuang KC; Giles W; Adamson J
Med Phys; 2021 Mar; 48(3):978-990. PubMed ID: 33332618
[TBL] [Abstract][Full Text] [Related]
22. Integration of AI and Machine Learning in Radiotherapy QA.
Chan MF; Witztum A; Valdes G
Front Artif Intell; 2020; 3():577620. PubMed ID: 33733216
[TBL] [Abstract][Full Text] [Related]
23. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy.
Mans A; Schuring D; Arends MP; Vugts CA; Wolthaus JW; Lotz HT; Admiraal M; Louwe RJ; Öllers MC; van de Kamer JB
Phys Med Biol; 2016 Oct; 61(19):7221-7235. PubMed ID: 27649474
[TBL] [Abstract][Full Text] [Related]
24. Evaluating AAPM-TG-218 recommendations: Gamma index tolerance and action limits in IMRT and VMAT quality assurance using SunCHECK.
Deng J; Liu S; Huang Y; Li X; Wu X
J Appl Clin Med Phys; 2024 Jun; 25(6):e14277. PubMed ID: 38243604
[TBL] [Abstract][Full Text] [Related]
25. MO-B-211-01: Linac-Based IMRT/VMAT Commissioning and QA Program Development.
Kim G; Cao D; Pawlicki T
Med Phys; 2012 Jun; 39(6Part21):3863. PubMed ID: 28518276
[TBL] [Abstract][Full Text] [Related]
26. Efficient dose-volume histogram-based pretreatment patient-specific quality assurance methodology with combined deep learning and machine learning models for volumetric modulated arc radiotherapy.
Gong C; Zhu K; Lin C; Han C; Lu Z; Chen Y; Yu C; Hou L; Zhou Y; Yi J; Ai Y; Xiang X; Xie C; Jin X
Med Phys; 2022 Dec; 49(12):7779-7790. PubMed ID: 36190117
[TBL] [Abstract][Full Text] [Related]
27. A single-optical kernel for a phosphor-screen-based geometric QA system (RavenQA
Lee M; Ding K; Yi B
Phys Med Biol; 2018 Oct; 63(20):20NT03. PubMed ID: 30255855
[TBL] [Abstract][Full Text] [Related]
28. Virtual pretreatment patient-specific quality assurance of volumetric modulated arc therapy using deep learning.
Yoganathan SA; Ahmed S; Paloor S; Torfeh T; Aouadi S; Al-Hammadi N; Hammoud R
Med Phys; 2023 Dec; 50(12):7891-7903. PubMed ID: 37379068
[TBL] [Abstract][Full Text] [Related]
29. Development of a deep learning-based error detection system without error dose maps in the patient-specific quality assurance of volumetric modulated arc therapy.
Kimura Y; Kadoya N; Oku Y; Jingu K
J Radiat Res; 2023 Jul; 64(4):728-737. PubMed ID: 37177789
[TBL] [Abstract][Full Text] [Related]
30. Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.
Lee B; Jeong S; Chung K; Yoon M; Park HC; Han Y; Jung SH
J Appl Clin Med Phys; 2019 Oct; 20(10):101-110. PubMed ID: 31544350
[TBL] [Abstract][Full Text] [Related]
31. Deep Learning for Patient-Specific Quality Assurance: Predicting Gamma Passing Rates for IMRT Based on Delivery Fluence Informed by log Files.
Huang Y; Pi Y; Ma K; Miao X; Fu S; Zhu Z; Cheng Y; Zhang Z; Chen H; Wang H; Gu H; Shao Y; Duan Y; Feng A; Zhuo W; Xu Z
Technol Cancer Res Treat; 2022; 21():15330338221104881. PubMed ID: 35726209
[No Abstract] [Full Text] [Related]
32. Applications of artificial intelligence for machine- and patient-specific quality assurance in radiation therapy: current status and future directions.
Ono T; Iramina H; Hirashima H; Adachi T; Nakamura M; Mizowaki T
J Radiat Res; 2024 May; ():. PubMed ID: 38798135
[TBL] [Abstract][Full Text] [Related]
33. Online adaptation and verification of VMAT.
Crijns W; Defraene G; Van Herck H; Depuydt T; Haustermans K; Maes F; Van den Heuvel F
Med Phys; 2015 Jul; 42(7):3877-91. PubMed ID: 26133589
[TBL] [Abstract][Full Text] [Related]
34. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
[TBL] [Abstract][Full Text] [Related]
35. Analyzation of the local confidence limits for IMRT and VMAT based on AAPM TG119 report.
Zhang J; Jiang D; Liu H; Shen J; Wang D; Chen C; Xie C; Cao Z
Med Dosim; 2020 Spring; 45(1):66-72. PubMed ID: 31296358
[TBL] [Abstract][Full Text] [Related]
36. Clinical implementation of a log file-based machine and patient QA system for IMRT and VMAT treatment plans.
Silvestri V; Raspanti D; Guerrisi MG; Falco MD
Phys Med; 2023 Apr; 108():102570. PubMed ID: 36989974
[TBL] [Abstract][Full Text] [Related]
37. Detecting MLC modeling errors using radiomics-based machine learning in patient-specific QA with an EPID for intensity-modulated radiation therapy.
Sakai M; Nakano H; Kawahara D; Tanabe S; Takizawa T; Narita A; Yamada T; Sakai H; Ueda M; Sasamoto R; Kaidu M; Aoyama H; Ishikawa H; Utsunomiya S
Med Phys; 2021 Mar; 48(3):991-1002. PubMed ID: 33382467
[TBL] [Abstract][Full Text] [Related]
38. Impact of the MLC leaf-tip model in a commercial TPS: Dose calculation limitations and IROC-H phantom failures.
Koger B; Price R; Wang D; Toomeh D; Geneser S; Ford E
J Appl Clin Med Phys; 2020 Feb; 21(2):82-88. PubMed ID: 31961036
[TBL] [Abstract][Full Text] [Related]
39. Practical approach for pretreatment verification of IMRT with flattening filter free(FFF) beams using Varian Portal Dosimetry.
Min S; Choi YE; Kwak J; Cho B
J Appl Clin Med Phys; 2014 Jan; 16(1):4934. PubMed ID: 25679149
[TBL] [Abstract][Full Text] [Related]
40. Report of AAPM Task Group 219 on independent calculation-based dose/MU verification for IMRT.
Zhu TC; Stathakis S; Clark JR; Feng W; Georg D; Holmes SM; Kry SF; Ma CC; Miften M; Mihailidis D; Moran JM; Papanikolaou N; Poppe B; Xiao Y
Med Phys; 2021 Oct; 48(10):e808-e829. PubMed ID: 34213772
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]