154 related articles for article (PubMed ID: 34351007)
1. Mapping gradient nonlinearity and miscalibration using diffusion-weighted MR images of a uniform isotropic phantom.
Barnett AS; Irfanoglu MO; Landman B; Rogers B; Pierpaoli C
Magn Reson Med; 2021 Dec; 86(6):3259-3273. PubMed ID: 34351007
[TBL] [Abstract][Full Text] [Related]
2. Assessment of the systematic errors caused by diffusion gradient inhomogeneity in DTI-computer simulations.
Borkowski K; Krzyżak AT
NMR Biomed; 2019 Nov; 32(11):e4130. PubMed ID: 31343807
[TBL] [Abstract][Full Text] [Related]
3. Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI.
Hansen CB; Rogers BP; Schilling KG; Nath V; Blaber JA; Irfanoglu O; Barnett A; Pierpaoli C; Anderson AW; Landman BA
Magn Reson Imaging; 2021 Feb; 76():69-78. PubMed ID: 33221421
[TBL] [Abstract][Full Text] [Related]
4. Phantom-based field maps for gradient nonlinearity correction in diffusion imaging.
Rogers BP; Blaber J; Newton AT; Hansen CB; Welch EB; Anderson AW; Luci JJ; Pierpaoli C; Landman BA
Proc SPIE Int Soc Opt Eng; 2018 Mar; 10573():. PubMed ID: 29887658
[TBL] [Abstract][Full Text] [Related]
5. The b matrix calculation using the anisotropic phantoms for DWI and DTI experiments.
Krzyzak AT; Klodowski K
Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():418-21. PubMed ID: 26736288
[TBL] [Abstract][Full Text] [Related]
6. Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction.
Malkyarenko DI; Chenevert TL
J Magn Reson Imaging; 2014 Dec; 40(6):1487-95. PubMed ID: 25667948
[TBL] [Abstract][Full Text] [Related]
7. Efficient gradient calibration based on diffusion MRI.
Teh I; Maguire ML; Schneider JE
Magn Reson Med; 2017 Jan; 77(1):170-179. PubMed ID: 26749277
[TBL] [Abstract][Full Text] [Related]
8. A theoretical validation of the B-matrix spatial distribution approach to diffusion tensor imaging.
Borkowski K; Kłodowski K; Figiel H; Krzyżak AT
Magn Reson Imaging; 2017 Feb; 36():1-6. PubMed ID: 27742435
[TBL] [Abstract][Full Text] [Related]
9. A method for calibrating diffusion gradients in diffusion tensor imaging.
Wu YC; Alexander AL
J Comput Assist Tomogr; 2007; 31(6):984-93. PubMed ID: 18043367
[TBL] [Abstract][Full Text] [Related]
10. The effect of elimination of gibbs ringing, noise and systematic errors on the DTI metrics and tractography in a rat brain.
Mazur-Rosmus W; Krzyżak AT
Sci Rep; 2024 Jul; 14(1):15010. PubMed ID: 38951163
[TBL] [Abstract][Full Text] [Related]
11. Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: evaluation using a diffusional anisotropic phantom.
Kim SJ; Choi CG; Kim JK; Yun SC; Jahng GH; Jeong HK; Kim EJ
Korean J Radiol; 2015; 16(2):297-303. PubMed ID: 25741191
[TBL] [Abstract][Full Text] [Related]
12. A method for improving the performance of gradient systems for diffusion-weighted MRI.
Nagy Z; Weiskopf N; Alexander DC; Deichmann R
Magn Reson Med; 2007 Oct; 58(4):763-8. PubMed ID: 17899604
[TBL] [Abstract][Full Text] [Related]
13. Extracting diffusion tensor fractional anisotropy and mean diffusivity from 3-direction DWI scans using deep learning.
Aliotta E; Nourzadeh H; Patel SH
Magn Reson Med; 2021 Feb; 85(2):845-854. PubMed ID: 32810351
[TBL] [Abstract][Full Text] [Related]
14. Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements.
Malyarenko DI; Ross BD; Chenevert TL
Magn Reson Med; 2014 Mar; 71(3):1312-23. PubMed ID: 23794533
[TBL] [Abstract][Full Text] [Related]
15. Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction.
Tao AT; Shu Y; Tan ET; Trzasko JD; Tao S; Reid RD; Weavers PT; Huston J; Bernstein MA
J Magn Reson Imaging; 2018 Dec; 48(6):1498-1507. PubMed ID: 30255963
[TBL] [Abstract][Full Text] [Related]
16. The adverse effect of gradient nonlinearities on diffusion MRI: From voxels to group studies.
Mesri HY; David S; Viergever MA; Leemans A
Neuroimage; 2020 Jan; 205():116127. PubMed ID: 31476431
[TBL] [Abstract][Full Text] [Related]
17. Stability of Gradient Field Corrections for Quantitative Diffusion MRI.
Rogers BP; Blaber J; Welch EB; Ding Z; Anderson AW; Landman BA
Proc SPIE Int Soc Opt Eng; 2017 Feb; 10132():. PubMed ID: 28736467
[TBL] [Abstract][Full Text] [Related]
18. Diffusion-Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient.
Wang J; Ma C; Yang P; Wang Z; Chen Y; Bian Y; Shao C; Lu J
J Magn Reson Imaging; 2023 Jul; 58(1):223-231. PubMed ID: 36373955
[TBL] [Abstract][Full Text] [Related]
19. Potential of a statistical approach for the standardization of multicenter diffusion tensor data: A phantom study.
Timmermans C; Smeets D; Verheyden J; Terzopoulos V; Anania V; Parizel PM; Maas A
J Magn Reson Imaging; 2019 Apr; 49(4):955-965. PubMed ID: 30605253
[TBL] [Abstract][Full Text] [Related]
20. Improving the accuracy of PGSE DTI experiments using the spatial distribution of b matrix.
Krzyżak AT; Olejniczak Z
Magn Reson Imaging; 2015 Apr; 33(3):286-95. PubMed ID: 25460327
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]