179 related articles for article (PubMed ID: 34351215)
21. Biomechanical comparison of fixation stability using a Lisfranc plate versus transarticular screws.
Ho NC; Sangiorgio SN; Cassinelli S; Shymon S; Fleming J; Agrawal V; Ebramzadeh E; Harris TG
Foot Ankle Surg; 2019 Feb; 25(1):71-78. PubMed ID: 29409256
[TBL] [Abstract][Full Text] [Related]
22. Crossed-screws provide greater tarsometatarsal fusion stability compared to compression plates.
Baxter JR; Mani SB; Chan JY; Vulcano E; Ellis SJ
Foot Ankle Spec; 2015 Apr; 8(2):95-100. PubMed ID: 25053793
[TBL] [Abstract][Full Text] [Related]
23. Stability of medial locking plate and compression screw versus two crossed screws for lapidus arthrodesis.
Klos K; Gueorguiev B; Mückley T; Fröber R; Hofmann GO; Schwieger K; Windolf M
Foot Ankle Int; 2010 Feb; 31(2):158-63. PubMed ID: 20132754
[TBL] [Abstract][Full Text] [Related]
24. Effect of lag screw on stability of first metatarsophalangeal joint arthrodesis with medial plate.
Daszkiewicz K; Rucka M; Czuraj K; Andrzejewska A; Łuczkiewicz P
PeerJ; 2024; 12():e16901. PubMed ID: 38436033
[TBL] [Abstract][Full Text] [Related]
25. Technique Tip.
Waryasz GR; Marcaccio S; Gil JA
Foot Ankle Spec; 2017 Apr; 10(2):149-151. PubMed ID: 28333559
[TBL] [Abstract][Full Text] [Related]
26. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw.
Claassen L; Plaass C; Pastor MF; Ettinger S; Wellmann M; Stukenborg-Colsman C; Hosseinian SHS; Waizy H
Arch Bone Jt Surg; 2017 Jul; 5(4):221-225. PubMed ID: 28913378
[TBL] [Abstract][Full Text] [Related]
27. Temporary Bridge Plating vs Primary Arthrodesis of the First Tarsometatarsal Joint in Lisfranc Injuries: Randomized Controlled Trial.
Stødle AH; Hvaal KH; Brøgger HM; Madsen JE; Husebye EE
Foot Ankle Int; 2020 Aug; 41(8):901-910. PubMed ID: 32501109
[TBL] [Abstract][Full Text] [Related]
28. Plate Alone Versus Plate and Lag Screw for Lapidus Arthrodesis: A Biomechanical Comparison of Compression.
Garas PK; DiSegna ST; Patel AR
Foot Ankle Spec; 2018 Dec; 11(6):534-538. PubMed ID: 29415564
[No Abstract] [Full Text] [Related]
29. The Lapidus Arthrodesis: Examining the Effect of the Metatarsal Base Transfixion Screw.
Ehredt DJ; Kawalec J; Ligas C; Seidel J; Benson B; Reiner MM; Connors J
J Foot Ankle Surg; 2021; 60(2):333-338. PubMed ID: 33349538
[TBL] [Abstract][Full Text] [Related]
30. Locking plate constructs benefit from interfragmentary lag screw fixation with decreased shear movements and more predictable fracture gap motion in simple fracture patterns.
Märdian S; Schmölz W; Schaser KD; Duda GN; Heyland M
Clin Biomech (Bristol, Avon); 2019 Dec; 70():89-96. PubMed ID: 31445402
[TBL] [Abstract][Full Text] [Related]
31. Interfragmentary lag screw fixation in locking plate constructs increases stiffness in simple fracture patterns.
Märdian S; Schmölz W; Schaser KD; Duda GN; Heyland M
Clin Biomech (Bristol, Avon); 2015 Oct; 30(8):814-9. PubMed ID: 26094776
[TBL] [Abstract][Full Text] [Related]
32. Comparative study of Lapidus bunionectomy using different osteosynthesis methods.
Gutteck N; Wohlrab D; Zeh A; Radetzki F; Delank KS; Lebek S
Foot Ankle Surg; 2013 Dec; 19(4):218-21. PubMed ID: 24095227
[TBL] [Abstract][Full Text] [Related]
33. Comparison of Locking Plate with Interfragmentary Screw Versus Plantarly Applied Anatomic Locking Plate for Lapidus Arthrodesis: A Biomechanical Cadaveric Study.
Cottom JM; Baker JS
Foot Ankle Spec; 2017 Jun; 10(3):227-231. PubMed ID: 27837037
[TBL] [Abstract][Full Text] [Related]
34. LagLoc-a new surgical technique for locking plate systems.
Triana M; Gueorguiev B; Sommer C; Stoffel K; Agarwal Y; Zderic I; Helfen T; Krieg JC; Krause F; Knobe M; Richards RG; Lenz M
J Orthop Res; 2018 Nov; 36(11):2886-2891. PubMed ID: 29917270
[TBL] [Abstract][Full Text] [Related]
35. Stability of Locking Plate and Compression Screws for Lapidus Arthrodesis: A Biomechanical Comparison of Plate Position.
Drummond D; Motley T; Kosmopoulos V; Ernst J
J Foot Ankle Surg; 2018; 57(3):466-470. PubMed ID: 29472168
[TBL] [Abstract][Full Text] [Related]
36. Rigidity comparison of locking plate and intramedullary fixation for tibiotalocalcaneal arthrodesis.
O'Neill PJ; Logel KJ; Parks BG; Schon LC
Foot Ankle Int; 2008 Jun; 29(6):581-6. PubMed ID: 18549754
[TBL] [Abstract][Full Text] [Related]
37. [Clinical and radiographic evaluation of open reduction and internal fixation with headless compression screws in treatment of lisfranc joint injuries].
Zhang H; Min L; Wang G; Liu L; Fang Y; Tu C
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Oct; 27(10):1196-201. PubMed ID: 24397130
[TBL] [Abstract][Full Text] [Related]
38. Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model.
Koroneos ZA; Manto KM; Martinazzi BJ; Stauch C; Bifano SM; Kunselman AR; Lewis GS; Aynardi M
Am J Sports Med; 2022 Oct; 50(12):3299-3307. PubMed ID: 35993448
[TBL] [Abstract][Full Text] [Related]
39. Biomechanical Comparison of Fixation Devices for First Metatarsocuneiform Joint Arthrodesis.
Knutsen AR; Fleming JF; Ebramzadeh E; Ho NC; Warganich T; Harris TG; Sangiorgio SN
Foot Ankle Spec; 2017 Aug; 10(4):322-328. PubMed ID: 27881829
[TBL] [Abstract][Full Text] [Related]
40. Talonavicular joint fixation: a biomechanical comparison of locking compression plates and lag screws.
Granata JD; Berlet GC; Ghotge R; Li Y; Kelly B; DiAngelo D
Foot Ankle Spec; 2014 Feb; 7(1):20-31. PubMed ID: 24381075
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]