These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 34363414)

  • 21. Prediction of Delayed Atrioventricular Block and Pacemaker Implantation After Transcatheter Aortic Valve Replacement With CoreValve.
    Kobayashi A; Misumida N
    Am J Cardiol; 2018 Feb; 121(3):393-394. PubMed ID: 29223288
    [No Abstract]   [Full Text] [Related]  

  • 22. Reply: Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement.
    Fadahunsi OO; Olowoyeye A; Ukaigwe A; Li Z; Vora AN; Vemulapalli S; Elgin E; Donato A
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1278-1279. PubMed ID: 28641855
    [No Abstract]   [Full Text] [Related]  

  • 23. Transcatheter Aortic Valve Replacement and New Conduction Abnormalities/Permanent Pacemaker: Can We Achieve the Intended Implant Depth?
    Piazza N; Lauzier P; Mylotte D
    JACC Cardiovasc Interv; 2016 Feb; 9(3):255-258. PubMed ID: 26847117
    [No Abstract]   [Full Text] [Related]  

  • 24. Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement.
    Jilaihawi H; Zhao Z; Du R; Staniloae C; Saric M; Neuburger PJ; Querijero M; Vainrib A; Hisamoto K; Ibrahim H; Collins T; Clark E; Pushkar I; Bamira D; Benenstein R; Tariq A; Williams M
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1796-1807. PubMed ID: 31473236
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Low Rates of Permanent Pacing Are Observed Following Self-Expanding Transcatheter Aortic Valve Replacement Using an Annular Plane Projection for Deployment.
    Pisaniello AD; Makki HBE; Jahangeer S; Daniels MJ; Hasan R; Fraser DGW
    Circ Cardiovasc Interv; 2021 Jan; 14(1):e009258. PubMed ID: 33430606
    [No Abstract]   [Full Text] [Related]  

  • 26. Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve.
    Gonska B; Seeger J; Keßler M; von Keil A; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2017 Aug; 106(8):590-597. PubMed ID: 28283746
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation.
    López-Aguilera J; Segura Saint-Gerons JM; Mazuelos Bellido F; Suárez de Lezo J; Ojeda Pineda S; Pan Álvarez-Ossorio M; Romero Moreno MÁ; Pavlovic D; Espejo Pérez S; Suárez de Lezo J
    Rev Esp Cardiol (Engl Ed); 2016 Jan; 69(1):28-36. PubMed ID: 26215663
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Permanent pacemaker implantation after transcatheter aortic valve replacement in bicuspid aortic valve patients.
    Xiong TY; Liao YB; Li YJ; Zhao ZG; Wei X; Tsauo JY; Xu YN; Feng Y; Chen M
    J Interv Cardiol; 2018 Dec; 31(6):878-884. PubMed ID: 30079561
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation.
    Husser O; Kessler T; Burgdorf C; Templin C; Pellegrini C; Schneider S; Kasel AM; Kastrati A; Schunkert H; Hengstenberg C
    Rev Esp Cardiol (Engl Ed); 2016 Feb; 69(2):141-8. PubMed ID: 26542175
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Insights into the need for permanent pacemaker following implantation of the repositionable LOTUS valve for transcatheter aortic valve replacement in 250 patients: results from the REPRISE II trial with extended cohort.
    Dumonteil N; Meredith IT; Blackman DJ; Tchétché D; Hildick-Smith D; Spence MS; Walters DL; Harnek J; Worthley SG; Rioufol G; Lefèvre T; Modine T; Van Mieghem N; Houle VM; Allocco DJ; Dawkins KD
    EuroIntervention; 2017 Sep; 13(7):796-803. PubMed ID: 28506942
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Predictors of permanent pacemaker implantation after transfemoral aortic valve implantation with the Lotus valve.
    Keßler M; Gonska B; Seeger J; Rottbauer W; Wöhrle J
    Am Heart J; 2017 Oct; 192():57-63. PubMed ID: 28938964
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis.
    Droppa M; Rudolph TK; Baan J; Nielsen NE; Baumgartner H; Vendrik J; Froehlich M; Borst O; Wöhrle J; Gawaz M; Potratz P; Hack LP; Mauri V; Baranowski J; Bramlage P; Kurucova J; Thoenes M; Rottbauer W; Geisler T
    Heart Vessels; 2020 Dec; 35(12):1735-1745. PubMed ID: 32591894
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement.
    Chamandi C; Barbanti M; Munoz-Garcia A; Latib A; Nombela-Franco L; Gutiérrez-Ibanez E; Veiga-Fernandez G; Cheema AN; Cruz-Gonzalez I; Serra V; Tamburino C; Mangieri A; Colombo A; Jiménez-Quevedo P; Elizaga J; Laughlin G; Lee DH; Garcia Del Blanco B; Rodriguez-Gabella T; Marsal JR; Côté M; Philippon F; Rodés-Cabau J
    JACC Cardiovasc Interv; 2018 Feb; 11(3):301-310. PubMed ID: 29413244
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Conduction recovery and avoidance of permanent pacing after transcatheter aortic valve implantation.
    Marzahn C; Koban C; Seifert M; Isotani A; Neuß M; Hölschermann F; Butter C
    J Cardiol; 2018 Jan; 71(1):101-108. PubMed ID: 28818562
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Non-pledget commissural suture technique to avoid atrioventricular block.
    Kunioka S; Fujita K; Iwasa S; Kamiya H; Yamazaki K; Tsukui H
    Gen Thorac Cardiovasc Surg; 2021 May; 69(5):906-908. PubMed ID: 33608837
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Modified annular suturing technique for minimizing postoperative pacemaker use after surgical aortic valve replacement.
    Yanagisawa H; Tabata M
    Gen Thorac Cardiovasc Surg; 2021 Feb; 69(2):254-259. PubMed ID: 32725475
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Impact of the repositionable Evolut R CoreValve system on the need for a permanent pacemaker after transcatheter aortic valve implantation in patients with severe aortic stenosis.
    Ojeda S; Hidalgo F; Romero M; Mazuelos F; Suárez de Lezo J; Martín E; Lostalo A; Luque A; González R; Fernández A; López-Aguilera J; Segura J; Guerrero N; Pan M
    Catheter Cardiovasc Interv; 2020 Mar; 95(4):783-790. PubMed ID: 31062927
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transcatheter Aortic Valve Replacement with the Lotus Valve: Concept and Current State of the Data.
    van Gils L; Van Mieghem NM
    Interv Cardiol Clin; 2019 Oct; 8(4):393-402. PubMed ID: 31445723
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transcatheter aortic valve implantation with a mechanically expandable prosthesis: a learning experience for permanent pacemaker implantation rate reduction.
    Ortak J; D'Ancona G; Ince H; Agma HU; Safak E; Öner A; Kische S
    Eur J Med Res; 2018 Mar; 23(1):14. PubMed ID: 29506581
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.