BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 34364994)

  • 1. Facile and direct detection of human papillomavirus (HPV) DNA in cells using loop-mediated isothermal amplification (LAMP).
    Vo DT; Story MD
    Mol Cell Probes; 2021 Oct; 59():101760. PubMed ID: 34364994
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High sensitivity, loop-mediated isothermal amplification combined with colorimetric gold-nanoparticle probes for visual detection of high risk human papillomavirus genotypes 16 and 18.
    Kumvongpin R; Jearanaikool P; Wilailuckana C; Sae-Ung N; Prasongdee P; Daduang S; Wongsena M; Boonsiri P; Kiatpathomchai W; Swangvaree SS; Sandee A; Daduang J
    J Virol Methods; 2016 Aug; 234():90-5. PubMed ID: 27086727
    [TBL] [Abstract][Full Text] [Related]  

  • 3. WarmStart colorimetric LAMP for the specific and rapid detection of HPV16 and HPV18 DNA.
    Daskou M; Tsakogiannis D; Dimitriou TG; Amoutzias GD; Mossialos D; Kottaridi C; Gartzonika C; Markoulatos P
    J Virol Methods; 2019 Aug; 270():87-94. PubMed ID: 31042552
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessing the performance of a Loop Mediated Isothermal Amplification (LAMP) assay for the detection and subtyping of high-risk suptypes of Human Papilloma Virus (HPV) for Oropharyngeal Squamous Cell Carcinoma (OPSCC) without DNA purification.
    Rohatensky MG; Livingstone DM; Mintchev P; Barnes HK; Nakoneshny SC; Demetrick DJ; Dort JC; van Marle G
    BMC Cancer; 2018 Feb; 18(1):166. PubMed ID: 29422018
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid diagnosis of seven high-risk human papillomavirus subtypes by a novel loop-mediated isothermal amplification method.
    Xi X; Cao WL; Yao X; Chen J; Huang D; Yang T; Liu Z; Xie W; Xia Y; Zhong T
    Mol Cell Probes; 2022 Feb; 61():101787. PubMed ID: 34875349
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of loop-mediated isothermal amplification assay for detection and typing of human papilloma virus 16 and 18 from endocervical samples.
    Mudhigeti N; Kalawat U; Hulikal N; Kante M
    Indian J Med Microbiol; 2019; 37(2):241-247. PubMed ID: 31745026
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Loop mediated isothermal amplification (LAMP) for the detection and subtyping of human papillomaviruses (HPV) in oropharyngeal squamous cell carcinoma (OPSCC).
    Livingstone DM; Rohatensky M; Mintchev P; Nakoneshny SC; Demetrick DJ; van Marle G; Dort JC
    J Clin Virol; 2016 Feb; 75():37-41. PubMed ID: 26780110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA.
    Jearanaikoon P; Prakrankamanant P; Leelayuwat C; Wanram S; Limpaiboon T; Promptmas C
    J Virol Methods; 2016 Mar; 229():8-11. PubMed ID: 26695714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development and application of a rapid detection system for human papillomavirus and Herpes simplex virus-2 by loop-mediated isothermal amplification assay.
    Yang JF; Zhao CZ; Lu KX
    Microb Pathog; 2016 Aug; 97():178-82. PubMed ID: 27287497
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Visual detection of high-risk HPV16 and HPV18 based on loop-mediated isothermal amplification.
    Fan Z; Feng X; Zhang W; Li N; Zhang X; Lin JM
    Talanta; 2020 Sep; 217():121015. PubMed ID: 32498911
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time loop-mediated isothermal amplification assay for rapid detection of human papillomavirus 16 in oral squamous cell carcinoma.
    Hamzan NI; Ab Rahman N; Suraiya S; Mohamad I; George Kalarakkal T; Mohamad S
    Arch Oral Biol; 2021 Apr; 124():105051. PubMed ID: 33581498
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Synergistically enhanced colorimetric molecular detection using smart cup: a case for instrument-free HPV-associated cancer screening.
    Yin K; Pandian V; Kadimisetty K; Ruiz C; Cooper K; You J; Liu C
    Theranostics; 2019; 9(9):2637-2645. PubMed ID: 31131058
    [No Abstract]   [Full Text] [Related]  

  • 13. Loop-mediated isothermal amplification method for detection of human papillomavirus type 6, 11, 16, and 18.
    Hagiwara M; Sasaki H; Matsuo K; Honda M; Kawase M; Nakagawa H
    J Med Virol; 2007 May; 79(5):605-15. PubMed ID: 17385684
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA.
    Zhang D; Liu D; Liu B; Ma X
    J Microbiol Biotechnol; 2021 Apr; 31(4):610-620. PubMed ID: 33526756
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Single-tube four-target lateral flow assay detects human papillomavirus types associated with majority of cervical cancers.
    Barra M; Chang M; Salcedo MP; Schmeler K; Scheurer M; Maza M; Lopez L; Alfaro K; Richards-Kortum R
    Anal Biochem; 2024 May; 688():115480. PubMed ID: 38331373
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prognostic Implication of Persistent Human Papillomavirus Type 16 DNA Detection in Oral Rinses for Human Papillomavirus-Related Oropharyngeal Carcinoma.
    Rettig EM; Wentz A; Posner MR; Gross ND; Haddad RI; Gillison ML; Fakhry C; Quon H; Sikora AG; Stott WJ; Lorch JH; Gourin CG; Guo Y; Xiao W; Miles BA; Richmon JD; Andersen PE; Misiukiewicz KJ; Chung CH; Gerber JE; Rajan SD; D'Souza G
    JAMA Oncol; 2015 Oct; 1(7):907-15. PubMed ID: 26226294
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Colorimetric detection of HPV6 and HPV16 by loop mediated isothermal amplification].
    Lu CB; Luo L; Yang MJ; Nie K; Wang M; Ma XJ
    Bing Du Xue Bao; 2011 Jan; 27(1):64-70. PubMed ID: 21462508
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection assay for HPV16 and HPV18 by loop‑mediated isothermal amplification with lateral flow dipstick tests.
    Kumvongpin R; Jearanaikoon P; Wilailuckana C; Sae-Ung N; Prasongdee P; Daduang S; Wongsena M; Boonsiri P; Kiatpathomchai W; Swangvaree SS; Sandee A; Daduang J
    Mol Med Rep; 2017 May; 15(5):3203-3209. PubMed ID: 28339040
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of high-risk human papillomavirus type 16 and 18 using isothermal helicase-dependent amplification.
    Barbieri D; Venturoli S; Rösl F; Rincon-Orozco B
    Diagn Microbiol Infect Dis; 2014 Jun; 79(2):178-82. PubMed ID: 24666707
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Colorimetric Detection of 23 Human Papillomavirus Genotypes by Loop-Mediated Isothermal Amplification.
    Lin J; Ma B; Fang J; Wang Y; He H; Lin W; Su W; Zhang M
    Clin Lab; 2017 Mar; 63(3):495-505. PubMed ID: 28271692
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.