These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 3437378)

  • 1. Monitoring arterial oxygen saturation in the neonate.
    Deckardt R; Schneider KT; Graeff H
    J Perinat Med; 1987; 15(4):357-60. PubMed ID: 3437378
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous neonatal evaluation in the delivery room by pulse oximetry.
    House JT; Schultetus RR; Gravenstein N
    J Clin Monit; 1987 Apr; 3(2):96-100. PubMed ID: 3585439
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical usefulness of pulse oximetry in the fetus with non-reassuring heart rate pattern?
    Schmidt S; Koslowski S; Sierra F; Meyer-Wittkopf M; Heller G
    J Perinat Med; 2000; 28(4):298-305. PubMed ID: 11031700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.
    Jennis MS; Peabody JL
    Pediatrics; 1987 Apr; 79(4):524-8. PubMed ID: 2434911
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of two wavelength pulse oximetry in neonates and infants.
    Praud JP; Carofilis A; Bridey F; Lacaille F; Dehan M; Gaultier CL
    Pediatr Pulmonol; 1989; 6(3):180-2. PubMed ID: 2470014
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The prediction of fetal acidosis by means of intrapartum fetal pulse oximetry.
    Seelbach-Göbel B; Heupel M; Kühnert M; Butterwegge M
    Am J Obstet Gynecol; 1999 Jan; 180(1 Pt 1):73-81. PubMed ID: 9914582
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The relationship between oxygen saturation and pH in umbilical blood: implications for intrapartum fetal oxygen saturation monitoring.
    Dildy GA; Thorp JA; Yeast JD; Clark SL
    Am J Obstet Gynecol; 1996 Sep; 175(3 Pt 1):682-7. PubMed ID: 8828434
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Fiberoptic measurement of arterial oxygen saturation in premature and term neonates].
    Merz U; Peschgens T; Hörnchen H
    Z Geburtshilfe Neonatol; 1999; 203(2):77-80. PubMed ID: 10420515
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulse oximetry for continuous oxygen monitoring in sick newborn infants.
    Durand M; Ramanathan R
    J Pediatr; 1986 Dec; 109(6):1052-6. PubMed ID: 2431130
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension.
    Fanconi S; Doherty P; Edmonds JF; Barker GA; Bohn DJ
    J Pediatr; 1985 Sep; 107(3):362-6. PubMed ID: 4032131
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative accuracy of pulse oximetry and transcutaneous oxygen in assessing arterial saturation in pediatric intensive care.
    Ross Russell RI; Helms PJ
    Crit Care Med; 1990 Jul; 18(7):725-7. PubMed ID: 2364712
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of oxygen saturation monitoring by pulse oximetry in neonates in the delivery system.
    Dimich I; Singh PP; Adell A; Hendler M; Sonnenklar N; Jhaveri M
    Can J Anaesth; 1991 Nov; 38(8):985-8. PubMed ID: 1752021
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation of neonatal acid-base status with Apgar scores and fetal heart rate tracings.
    Page FO; Martin JN; Palmer SM; Martin RW; Lucas JA; Meeks GR; Bucovaz ET; Morrison JC
    Am J Obstet Gynecol; 1986 Jun; 154(6):1306-11. PubMed ID: 3717240
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring the resuscitation of preterm infants in the delivery room using pulse oximetry.
    Maxwell LG; Harris AP; Sendak MJ; Donham RT
    Clin Pediatr (Phila); 1987 Jan; 26(1):18-20. PubMed ID: 3791833
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulse oximetry and transcutaneous oxygen tension for detection of hypoxemia in critically ill infants and children.
    Fanconi S
    Adv Exp Med Biol; 1987; 220():159-64. PubMed ID: 3673758
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Arterial oxygen saturation in healthy newborns delivered at term in Cerro de Pasco (4340 m) and Lima (150 m).
    Gonzales GF; Salirrosas A
    Reprod Biol Endocrinol; 2005 Sep; 3():46. PubMed ID: 16156890
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
    Giguère S; Sanchez LC; Shih A
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):529-35. PubMed ID: 25212699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Apgar score: is it enough?
    Silverman F; Suidan J; Wasserman J; Antoine C; Young BK
    Obstet Gynecol; 1985 Sep; 66(3):331-6. PubMed ID: 3927209
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Longtime performance and reliability of two different PtcCO2 and SpO2 sensors in neonates.
    Bernet V; Döll C; Cannizzaro V; Ersch J; Frey B; Weiss M
    Paediatr Anaesth; 2008 Sep; 18(9):872-7. PubMed ID: 18768047
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.