These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 34382401)

  • 41. Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations.
    Ibrahim YM; Hamid AM; Cox JT; Garimella SV; Smith RD
    Anal Chem; 2017 Feb; 89(3):1972-1977. PubMed ID: 28208272
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Combined hydrophilic interaction liquid chromatography-scanning field asymmetric waveform ion mobility spectrometry-time-of-flight mass spectrometry for untargeted metabolomics.
    Szykuła KM; Meurs J; Turner MA; Creaser CS; Reynolds JC
    Anal Bioanal Chem; 2019 Sep; 411(24):6309-6317. PubMed ID: 31011786
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A Strategy for Identification and Structural Characterization of Compounds from
    Gao H; Liu Z; Song F; Xing J; Zheng Z; Liu S
    Molecules; 2022 Jul; 27(13):. PubMed ID: 35807548
    [No Abstract]   [Full Text] [Related]  

  • 44. LipidMatch: an automated workflow for rule-based lipid identification using untargeted high-resolution tandem mass spectrometry data.
    Koelmel JP; Kroeger NM; Ulmer CZ; Bowden JA; Patterson RE; Cochran JA; Beecher CWW; Garrett TJ; Yost RA
    BMC Bioinformatics; 2017 Jul; 18(1):331. PubMed ID: 28693421
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A comparison of collision cross section values obtained via travelling wave ion mobility-mass spectrometry and ultra high performance liquid chromatography-ion mobility-mass spectrometry: Application to the characterisation of metabolites in rat urine.
    Nye LC; Williams JP; Munjoma NC; Letertre MPM; Coen M; Bouwmeester R; Martens L; Swann JR; Nicholson JK; Plumb RS; McCullagh M; Gethings LA; Lai S; Langridge JI; Vissers JPC; Wilson ID
    J Chromatogr A; 2019 Sep; 1602():386-396. PubMed ID: 31285057
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Application of differential mobility-mass spectrometry for untargeted human plasma metabolomic analysis.
    Wernisch S; Pennathur S
    Anal Bioanal Chem; 2019 Sep; 411(24):6297-6308. PubMed ID: 30941479
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Rapid Quantitation of 25-Hydroxyvitamin D2 and D3 in Human Serum Using Liquid Chromatography/Drift Tube Ion Mobility-Mass Spectrometry.
    Oranzi NR; Lei J; Kemperman RHJ; Chouinard CD; Holmquist B; Garrett TJ; Yost RA
    Anal Chem; 2019 Nov; 91(21):13555-13561. PubMed ID: 31592654
    [TBL] [Abstract][Full Text] [Related]  

  • 48. An Interlaboratory Evaluation of Drift Tube Ion Mobility-Mass Spectrometry Collision Cross Section Measurements.
    Stow SM; Causon TJ; Zheng X; Kurulugama RT; Mairinger T; May JC; Rennie EE; Baker ES; Smith RD; McLean JA; Hann S; Fjeldsted JC
    Anal Chem; 2017 Sep; 89(17):9048-9055. PubMed ID: 28763190
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Implementation of Ion Mobility Spectrometry-Based Separations in Structures for Lossless Ion Manipulations (SLIM).
    Hollerbach AL; Conant CR; Nagy G; Ibrahim YM
    Methods Mol Biol; 2022; 2394():453-469. PubMed ID: 35094340
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Metabolomics Data Preprocessing Using ADAP and MZmine 2.
    Du X; Smirnov A; Pluskal T; Jia W; Sumner S
    Methods Mol Biol; 2020; 2104():25-48. PubMed ID: 31953811
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A new method to search for per- and polyfluoroalkyl substances (PFASs) by linking fragmentation flags with their molecular ions by drift time using ion mobility spectrometry.
    Yukioka S; Tanaka S; Suzuki Y; Fujii S; Echigo S
    Chemosphere; 2020 Jan; 239():124644. PubMed ID: 31514004
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Optimization of a liquid chromatography-ion mobility-high resolution mass spectrometry platform for untargeted lipidomics and application to HepaRG cell extracts.
    da Silva KM; Iturrospe E; Heyrman J; Koelmel JP; Cuykx M; Vanhaecke T; Covaci A; van Nuijs ALN
    Talanta; 2021 Dec; 235():122808. PubMed ID: 34517665
    [TBL] [Abstract][Full Text] [Related]  

  • 53. MZA: A Data Conversion Tool to Facilitate Software Development and Artificial Intelligence Research in Multidimensional Mass Spectrometry.
    Bilbao A; Ross DH; Lee JY; Donor MT; Williams SM; Zhu Y; Ibrahim YM; Smith RD; Zheng X
    J Proteome Res; 2023 Feb; 22(2):508-513. PubMed ID: 36414245
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Integrating ion mobility and imaging mass spectrometry for comprehensive analysis of biological tissues: A brief review and perspective.
    Rivera ES; Djambazova KV; Neumann EK; Caprioli RM; Spraggins JM
    J Mass Spectrom; 2020 Dec; 55(12):e4614. PubMed ID: 32955134
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Theoretical evaluation of peak capacity improvements by use of liquid chromatography combined with drift tube ion mobility-mass spectrometry.
    Causon TJ; Hann S
    J Chromatogr A; 2015 Oct; 1416():47-56. PubMed ID: 26372446
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Mobility-resolved ion selection in uniform drift field ion mobility spectrometry/mass spectrometry: dynamic switching in structures for lossless ion manipulations.
    Webb IK; Garimella SV; Tolmachev AV; Chen TC; Zhang X; Cox JT; Norheim RV; Prost SA; LaMarche B; Anderson GA; Ibrahim YM; Smith RD
    Anal Chem; 2014 Oct; 86(19):9632-7. PubMed ID: 25222548
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis.
    Hollerbach AL; Ibrahim YM; Meras V; Norheim RV; Huntley AP; Anderson GA; Metz TO; Ewing RG; Smith RD
    Anal Chem; 2023 Jun; 95(25):9531-9538. PubMed ID: 37307303
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Rapid profiling method for the analysis of lipids in human plasma using ion mobility enabled-reversed phase-ultra high performance liquid chromatography/mass spectrometry.
    King AM; Trengove RD; Mullin LG; Rainville PD; Isaac G; Plumb RS; Gethings LA; Wilson ID
    J Chromatogr A; 2020 Jan; 1611():460597. PubMed ID: 31619360
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Accurate Quantitative Proteomic Analyses Using Metabolic Labeling and High Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS).
    Pfammatter S; Bonneil E; McManus FP; Thibault P
    J Proteome Res; 2019 May; 18(5):2129-2138. PubMed ID: 30919622
    [TBL] [Abstract][Full Text] [Related]  

  • 60. T-wave ion mobility-mass spectrometry: basic experimental procedures for protein complex analysis.
    Michaelevski I; Kirshenbaum N; Sharon M
    J Vis Exp; 2010 Jul; (41):. PubMed ID: 20729801
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.