171 related articles for article (PubMed ID: 34397114)
1. Rapid safety assessment and mitigation of radiofrequency induced implant heating using small root mean square sensors and the sensor matrix Q
Silemek B; Seifert F; Petzold J; Hoffmann W; Pfeiffer H; Speck O; Rose G; Ittermann B; Winter L
Magn Reson Med; 2022 Jan; 87(1):509-527. PubMed ID: 34397114
[TBL] [Abstract][Full Text] [Related]
2. Parallel transmission medical implant safety testbed: Real-time mitigation of RF induced tip heating using time-domain E-field sensors.
Winter L; Silemek B; Petzold J; Pfeiffer H; Hoffmann W; Seifert F; Ittermann B
Magn Reson Med; 2020 Dec; 84(6):3468-3484. PubMed ID: 32639681
[TBL] [Abstract][Full Text] [Related]
3. Towards an integrated radiofrequency safety concept for implant carriers in MRI based on sensor-equipped implants and parallel transmission.
Petzold J; Schmitter S; Silemek B; Winter L; Speck O; Ittermann B; Seifert F
NMR Biomed; 2023 Jul; 36(7):e4900. PubMed ID: 36624556
[TBL] [Abstract][Full Text] [Related]
4. Wirelessly interfacing sensor-equipped implants and MR scanners for improved safety and imaging.
Silemek B; Seifert F; Petzold J; Brühl R; Ittermann B; Winter L
Magn Reson Med; 2023 Dec; 90(6):2608-2626. PubMed ID: 37533167
[TBL] [Abstract][Full Text] [Related]
5. Numerical Simulations of Realistic Lead Trajectories and an Experimental Verification Support the Efficacy of Parallel Radiofrequency Transmission to Reduce Heating of Deep Brain Stimulation Implants during MRI.
McElcheran CE; Golestanirad L; Iacono MI; Wei PS; Yang B; Anderson KJT; Bonmassar G; Graham SJ
Sci Rep; 2019 Feb; 9(1):2124. PubMed ID: 30765724
[TBL] [Abstract][Full Text] [Related]
6. An 8 channel parallel transmit system with current sensor feedback for MRI-guided interventional applications.
Godinez F; Tomi-Tricot R; Quesson B; Barthel M; Lykowsky G; Scott G; Razavi R; Hajnal J; Malik S
Phys Med Biol; 2021 Nov; 66(21):. PubMed ID: 34649230
[No Abstract] [Full Text] [Related]
7. Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating.
Gudino N; Sonmez M; Yao Z; Baig T; Nielles-Vallespin S; Faranesh AZ; Lederman RJ; Martens M; Balaban RS; Hansen MS; Griswold MA
Med Phys; 2015 Jan; 42(1):359-71. PubMed ID: 25563276
[TBL] [Abstract][Full Text] [Related]
8. Application of Machine learning to predict RF heating of cardiac leads during magnetic resonance imaging at 1.5 T and 3 T: A simulation study.
Chen X; Zheng C; Golestanirad L
J Magn Reson; 2023 Apr; 349():107384. PubMed ID: 36842429
[TBL] [Abstract][Full Text] [Related]
9. Adaptive SAR mass-averaging framework to improve predictions of local RF heating near a hip implant for parallel transmit at 7 T.
Destruel A; O'Brien K; Jin J; Liu F; Barth M; Crozier S
Magn Reson Med; 2019 Jan; 81(1):615-627. PubMed ID: 30058186
[TBL] [Abstract][Full Text] [Related]
10. Dependence of RF heating on SAR and implant position in a 1.5T MR system.
Muranaka H; Horiguchi T; Usui S; Ueda Y; Nakamura O; Ikeda F
Magn Reson Med Sci; 2007; 6(4):199-209. PubMed ID: 18239357
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of RF heating on humerus implant in phantoms during 1.5T MR imaging and comparisons with electromagnetic simulation.
Muranaka H; Horiguchi T; Usui S; Ueda Y; Nakamura O; Ikeda F; Iwakura K; Nakaya G
Magn Reson Med Sci; 2006 Jul; 5(2):79-88. PubMed ID: 17008764
[TBL] [Abstract][Full Text] [Related]
12. Thermo-acoustic ultrasound for noninvasive temperature monitoring at lead tips during MRI.
Dixit N; Pauly JM; Scott GC
Magn Reson Med; 2020 Aug; 84(2):1035-1047. PubMed ID: 31883207
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of RF heating due to various implants during MR procedures.
Muranaka H; Horiguchi T; Ueda Y; Tanki N
Magn Reson Med Sci; 2011; 10(1):11-9. PubMed ID: 21441723
[TBL] [Abstract][Full Text] [Related]
14. Effect of inter-electrode RF coupling on heating patterns of wire-like conducting implants in MRI.
Bhusal B; Bhattacharyya P; Baig T; Jones S; Martens M
Magn Reson Med; 2022 Jun; 87(6):2933-2946. PubMed ID: 35092097
[TBL] [Abstract][Full Text] [Related]
15. RF-induced heating for active implantable medical devices in dual parallel leads configurations at 1.5 T MRI.
Hu W; Guo R; Wang Q; Zheng J; Tsang J; Kainz W; Long S; Chen J
Magn Reson Med; 2023 Aug; 90(2):686-698. PubMed ID: 37036364
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of RF heating on hip joint implant in phantom during MRI examinations.
Muranaka H; Horiguchi T; Ueda Y; Usui S; Tanki N; Nakamura O
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2010 Jul; 66(7):725-33. PubMed ID: 20702992
[TBL] [Abstract][Full Text] [Related]
17. A numerical and experimental study of RF shimming in the presence of hip prostheses using adaptive SAR at 3 T.
Destruel A; Fuentes M; Weber E; O'Brien K; Jin J; Liu F; Barth M; Crozier S
Magn Reson Med; 2019 Jun; 81(6):3826-3839. PubMed ID: 30803001
[TBL] [Abstract][Full Text] [Related]
18. Computational and experimental investigation of RF-induced heating for multiple orthopedic implants.
Guo R; Zheng J; Wang Y; Zeng Q; Wang Q; Yang R; Kainz W; Chen J
Magn Reson Med; 2019 Nov; 82(5):1848-1858. PubMed ID: 31183897
[TBL] [Abstract][Full Text] [Related]
19. Reduction of implant RF heating through modification of transmit coil electric field.
Eryaman Y; Akin B; Atalar E
Magn Reson Med; 2011 May; 65(5):1305-13. PubMed ID: 21500259
[TBL] [Abstract][Full Text] [Related]
20. Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging.
McElcheran CE; Yang B; Anderson KJ; Golenstani-Rad L; Graham SJ
PLoS One; 2015; 10(8):e0134379. PubMed ID: 26237218
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]