  • 21. Validation of a novel respiratory rate monitor based on exhaled humidity.
    Niesters M; Mahajan R; Olofsen E; Boom M; Garcia Del Valle S; Aarts L; Dahan A
    Br J Anaesth; 2012 Dec; 109(6):981-9. PubMed ID: 22907341
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Simple Wireless Impedance Pneumography System for Unobtrusive Sensing of Respiration.
    Aqueveque P; Gómez B; Monsalve E; Germany E; Ortega-Bastidas P; Dubo S; Pino EJ
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32937770
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Feasibility of non-contact cardiorespiratory monitoring using impulse-radio ultra-wideband radar in the neonatal intensive care unit.
    Lee WH; Lee Y; Na JY; Kim SH; Lee HJ; Lim YH; Cho SH; Cho SH; Park HK
    PLoS One; 2020; 15(12):e0243939. PubMed ID: 33370375
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Detecting Subclinical Diabetic Cardiac Autonomic Neuropathy by Analyzing Ventricular Repolarization Dynamics.
    Imam MH; Karmakar CK; Jelinek HF; Palaniswami M; Khandoker AH
    IEEE J Biomed Health Inform; 2016 Jan; 20(1):64-72. PubMed ID: 25915966
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Monitoring the respiratory rate by miniature motion sensors in premature infants: a comparative study.
    Kohn S; Waisman D; Pesin J; Faingersh A; Klotzman IC; Levy C; Hirshberg G; Rotschild A; Landesberg A
    J Perinatol; 2016 Feb; 36(2):116-20. PubMed ID: 26583946
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Tidal breathing flow volume profiles during sleep in wheezing infants measured by impedance pneumography.
    Gracia-Tabuenca J; Seppä VP; Jauhiainen M; Kotaniemi-Syrjänen A; Malmström K; Pelkonen A; Mäkelä M; Viik J; Malmberg LP
    J Appl Physiol (1985); 2019 May; 126(5):1409-1418. PubMed ID: 30763165
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Motion Artifact Suppression in Impedance Pneumography Signal for Portable Monitoring of Respiration: An Adaptive Approach.
    Ansari S; Ward KR; Najarian K
    IEEE J Biomed Health Inform; 2017 Mar; 21(2):387-398. PubMed ID: 26863681
    [TBL] [Abstract][Full Text] [Related]  

  • 28. ECG-derived respirations based on phase-space reconstruction of single-lead ECG: validations over various physical activities based on parallel recordings of ECG, respiration, and body accelerations.
    Hsiao-Lung Chan ; Shen-Hsiung Lin ; Fu-Tai Wang ; Wen-Yen Hsu ; Chun-Li Wang
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():2282-5. PubMed ID: 25570443
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Electrocardiogram Derived Respiratory Signal through the Segmented-Beat Modulation Method.
    Pambianco B; Sbrollini A; Marcantoni I; Morettini M; Fioretti S; Burattini L
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5681-5684. PubMed ID: 30441625
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of acoustic and impedance methods with mask capnometry to assess respiration rate in obese patients recovering from general anaesthesia.
    Frasca D; Geraud L; Charriere JM; Debaene B; Mimoz O
    Anaesthesia; 2015 Jan; 70(1):26-31. PubMed ID: 25040754
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ictal and interictal respiratory changes in temporal lobe and absence epilepsy in childhood.
    Jansen K; Varon C; Van Huffel S; Lagae L
    Epilepsy Res; 2013 Oct; 106(3):410-6. PubMed ID: 23948397
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Real-time estimation of the ECG-derived respiration (EDR) signal using a new algorithm for baseline wander noise removal.
    Arunachalam SP; Brown LF
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():5681-4. PubMed ID: 19964140
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an Emergency Department for drug or alcoholic poisoning.
    Guechi Y; Pichot A; Frasca D; Rayeh-Pelardy F; Lardeur JY; Mimoz O
    J Clin Monit Comput; 2015 Dec; 29(6):721-6. PubMed ID: 25614223
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography.
    Bergese SD; Mestek ML; Kelley SD; McIntyre R; Uribe AA; Sethi R; Watson JN; Addison PS
    Anesth Analg; 2017 Apr; 124(4):1153-1159. PubMed ID: 28099286
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Tidal breathing flow measurement in awake young children by using impedance pneumography.
    Seppä VP; Pelkonen AS; Kotaniemi-Syrjänen A; Mäkelä MJ; Viik J; Malmberg LP
    J Appl Physiol (1985); 2013 Dec; 115(11):1725-31. PubMed ID: 24092693
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Real-time obstructive sleep apnea detection from frequency analysis of EDR and HRV using Lomb Periodogram.
    Fan SH; Chou CC; Chen WC; Fang WC
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():5989-92. PubMed ID: 26737656
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A systematic review and synthesis of the strengths and limitations of measuring malaria mortality through verbal autopsy.
    Herrera S; Enuameh Y; Adjei G; Ae-Ngibise KA; Asante KP; Sankoh O; Owusu-Agyei S; Yé Y
    Malar J; 2017 Oct; 16(1):421. PubMed ID: 29058621
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A method for suppressing cardiogenic oscillations in impedance pneumography.
    Seppä VP; Hyttinen J; Viik J
    Physiol Meas; 2011 Mar; 32(3):337-45. PubMed ID: 21321385
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A novel approach towards non-obstructive detection and classification of COPD using ECG derived respiration.
    Sarkar S; Bhattacharyya P; Mitra M; Pal S
    Australas Phys Eng Sci Med; 2019 Dec; 42(4):1011-1024. PubMed ID: 31602592