These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 34410680)

  • 1. Helical plating - a novel technique to increase stiffness in defect fractures.
    Lenz M; Varga P; Mischler D; Gueorguiev B; Klos K; Fernandez dell'Oca A; Regazzoni P; Richards RG; Perren SM
    Eur Cell Mater; 2021 Aug; 42():110-121. PubMed ID: 34410680
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical and biological aspects of defect treatment in fractures using helical plates.
    Perren SM; Regazzoni P; Fernandez AA
    Acta Chir Orthop Traumatol Cech; 2014; 81(4):267-71. PubMed ID: 25137496
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
    Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
    Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Internal fixation of type-C distal femoral fractures in osteoporotic bone: surgical technique.
    Mückley T; Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO
    J Bone Joint Surg Am; 2011 Mar; 93 Suppl 1():40-53. PubMed ID: 21411685
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical evaluation of periprosthetic femoral fracture fixation.
    Zdero R; Walker R; Waddell JP; Schemitsch EH
    J Bone Joint Surg Am; 2008 May; 90(5):1068-77. PubMed ID: 18451400
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
    Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
    J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.
    Lenz M; Acklin YP; Kasper LA; Mischler D; Varga P; Zderic I; Gehweiler D; Klos K; Gueorguiev B; Stoffel K
    J Biomech; 2021 Jan; 115():110109. PubMed ID: 33257010
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical evaluation of retrograde docking nailing to a total hip arthroplasty stem in a periprosthetic femur fracture model.
    Lenz M; Hofmann-Fliri L; Kasper LA; Varga P; Zderic I; Gehweiler D; Klos K; Hofmann GO; Stoffel K; Gueorguiev B
    Injury; 2021 Jan; 52(1):53-59. PubMed ID: 33129493
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Supplemental Fixation of Supracondylar Distal Femur Fractures: A Biomechanical Comparison of Dual-Plate and Plate-Nail Constructs.
    Wright DJ; DeSanto DJ; McGarry MH; Lee TQ; Scolaro JA
    J Orthop Trauma; 2020 Aug; 34(8):434-440. PubMed ID: 32032183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength.
    Bottlang M; Doornink J; Fitzpatrick DC; Madey SM
    J Bone Joint Surg Am; 2009 Aug; 91(8):1985-94. PubMed ID: 19651958
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Additional fixation of medial plate over the unstable lateral locked plating of distal femur fractures: A biomechanical study.
    Park KH; Oh CW; Park IH; Kim JW; Lee JH; Kim HJ
    Injury; 2019 Oct; 50(10):1593-1598. PubMed ID: 31288939
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
    Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
    J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Locked plating of comminuted distal femur fractures: does unlocked screw placement affect stability and failure?
    Cui S; Bledsoe JG; Israel H; Watson JT; Cannada LK
    J Orthop Trauma; 2014 Feb; 28(2):90-6. PubMed ID: 23860132
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparison of distal femoral fracture fixation: Analysis of non-locked, locked, and far-cortical locked constructs.
    Riedel MD; Oppizzi G; O'Hara NN; Zhang C; Koh K; Slobogean GP; Zhang LQ; O'Toole RV
    J Orthop Res; 2020 Dec; 38(12):2573-2579. PubMed ID: 32470168
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.
    Niederhäuser SK; Tepic S; Weber UT
    Am J Vet Res; 2015 May; 76(5):402-10. PubMed ID: 25909372
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical Evaluation of Dual Plate Configurations for Femoral Shaft Fracture Fixation.
    El Beaino M; Morris RP; Lindsey RW; Gugala Z
    Biomed Res Int; 2019; 2019():5958631. PubMed ID: 31183369
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical comparison of endosteal substitution and lateral plate fixation in supracondylar fractures of the femur.
    Prayson MJ; Datta DK; Marshall MP
    J Orthop Trauma; 2001 Feb; 15(2):96-100. PubMed ID: 11232661
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical Study of Intramedullary Versus Extramedullary Implants for Four Types of Subtrochanteric Femoral Fracture.
    Wang J; Jia H; Ma X; Ma J; Lu B; Bai H; Wang Y
    Orthop Surg; 2022 Aug; 14(8):1884-1891. PubMed ID: 35706129
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Internal fixation of supracondylar femoral fractures: comparative biomechanical performance of the 95-degree blade plate and two retrograde nails.
    Ito K; Grass R; Zwipp H
    J Orthop Trauma; 1998 May; 12(4):259-66. PubMed ID: 9619461
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.