These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 3442074)

  • 21. A computer model of the pediatric circulatory system for testing pediatric assist devices.
    Giridharan GA; Koenig SC; Mitchell M; Gartner M; Pantalos GM
    ASAIO J; 2007; 53(1):74-81. PubMed ID: 17237652
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data.
    Morley D; Litwak K; Ferber P; Spence P; Dowling R; Meyns B; Griffith B; Burkhoff D
    J Thorac Cardiovasc Surg; 2007 Jan; 133(1):21-8. PubMed ID: 17198776
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Right ventricular balloon pumping.
    Kabei N; Tsuchiya K; Sakurai Y
    Life Support Syst; 1985; 3(4):343-55. PubMed ID: 4068756
    [TBL] [Abstract][Full Text] [Related]  

  • 24. New techniques in mechanical cardiac support.
    Crit Care Clin; 1986 Apr; 2(2):191-375. PubMed ID: 3454244
    [No Abstract]   [Full Text] [Related]  

  • 25. The use of centrifugal flow pumps in a model of experimental right heart failure.
    Hinton CB; Cornum RL; Elliott DC; Edwards FH; Macon MG; Callahan S; Graeber GM
    Curr Surg; 1988; 45(6):471-3. PubMed ID: 3234023
    [No Abstract]   [Full Text] [Related]  

  • 26. Artificial hearts and blood pumps in the treatment of profound heart failure.
    Pierce WS
    Circulation; 1983 Oct; 68(4):883-8. PubMed ID: 6616783
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Real-time cardiac output estimation of the circulatory system under left ventricular assistance.
    Yoshizawa M; Takeda H; Miura M; Yambe T; Katahira Y; Nitta S
    IEEE Trans Biomed Eng; 1993 Mar; 40(3):266-75. PubMed ID: 8335330
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Hypertonic-hyperoncotic solutions improve cardiac function in children after open-heart surgery.
    Schroth M; Plank C; Meissner U; Eberle KP; Weyand M; Cesnjevar R; Dötsch J; Rascher W
    Pediatrics; 2006 Jul; 118(1):e76-84. PubMed ID: 16751617
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design of an artificial left ventricular muscle: an innovative way to actuate blood pumps?
    Van Der Smissen B; Claessens T; Verdonck P; Van Ransbeeck P; Segers P
    Artif Organs; 2009 Jun; 33(6):464-8. PubMed ID: 19473142
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Possibilities of using cardiovascular assist systems and the artificial heart].
    Urbaszek W
    Z Gesamte Inn Med; 1986 May; 41(10):286-90. PubMed ID: 3529661
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hardware-in-the-loop-simulation of the cardiovascular system, with assist device testing application.
    Hanson BM; Levesley MC; Watterson K; Walker PG
    Med Eng Phys; 2007 Apr; 29(3):367-74. PubMed ID: 16815728
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of cannulation and flow-regulation technique of the Aachen/Düsseldorf left heart assist system.
    Schultheis R; Jaeschock R; Schneider W; Bialonski H; Rautenbach R; Arnold G
    Trans Am Soc Artif Intern Organs; 1982; 28():567-71. PubMed ID: 7164303
    [No Abstract]   [Full Text] [Related]  

  • 33. The development of a valveless cardiac assist device attached to the ventricular apex.
    van Loon J; Wilde JC; Topaz SR; Bishop ND; Shelton A; Marten C; Pantalos G; Kolff WJ; Thomas G; Nakajima H
    ASAIO J; 1994; 40(2):171-5. PubMed ID: 8003754
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effect of left ventricular function and drive pressures on the filling and ejection of a pulsatile pediatric ventricular assist device in an acute animal model.
    Lukic B; Zapanta CM; Khalapyan T; Connell J; Pae WE; Myers JL; Wilson RP; Undar A; Rosenberg G; Weiss WJ
    ASAIO J; 2007; 53(3):379-84. PubMed ID: 17515733
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Development of mechanical heart devices.
    DeBakey ME
    Ann Thorac Surg; 2005 Jun; 79(6):S2228-31. PubMed ID: 15919257
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Indirect measurement technique for a portable artificial heart drive system.
    Kitamura T; Whang DH
    ISA Trans; 1986; 25(4):7-11. PubMed ID: 3793428
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Instrumental technology for assisted circulation from the Manfred von Ardenne Research Institute, Dresden].
    von Ardenne M; Gündel W; Jonas B
    Z Exp Chir Transplant Kunstliche Organe; 1986; 19(3):135-46. PubMed ID: 3529666
    [No Abstract]   [Full Text] [Related]  

  • 38. Development of a paracorporeal left ventricular assist pump system: an experimental study.
    LeGal YM; Bartlett RB; Couves CM
    Artif Organs; 1981 Feb; 5(1):26-37. PubMed ID: 7247753
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pneumatically powered blood pumps used as a bridge to cardiac transplantation. Characteristics and development.
    Robison PD; Pantalos GM; Olsen DB
    Crit Care Nurs Clin North Am; 1989 Sep; 1(3):485-94. PubMed ID: 2684239
    [No Abstract]   [Full Text] [Related]  

  • 40. The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.
    Nawrat Z; Malota Z
    Artif Organs; 1998 Oct; 22(10):898-904. PubMed ID: 9790090
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.