These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 3442985)

  • 21. First-use syndrome and hypersensitivity during hemodialysis: some pieces of the puzzle are falling into place.
    Ing TS; Ivanovich PT; Daugirdas JT
    Artif Organs; 1987 Apr; 11(2):79-81. PubMed ID: 3593048
    [No Abstract]   [Full Text] [Related]  

  • 22. [Allergy to ethylene oxide in dental patients].
    Papadimitriou-Delantoni P; Margari-Papanicolaou V; Eleftheriadis I; Pastourmazi B; Hatzifotiadis D
    Hell Period Stomat Gnathopathoprosopike Cheir; 1990 Sep; 5(3):113-4. PubMed ID: 2130064
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Ethylene oxide hypersensitivity in dialysis patients.
    Röckel A; Wahn V; Hertel J; Fiegel P
    Lancet; 1986 Feb; 1(8477):382-3. PubMed ID: 2868318
    [No Abstract]   [Full Text] [Related]  

  • 24. Anaphylactoid reactions during haemodialysis are due to ethylene oxide hypersensitivity.
    Nicholls AJ; Platts MM
    Proc Eur Dial Transplant Assoc Eur Ren Assoc; 1985; 21():173-7. PubMed ID: 3991498
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Ethylene oxide and hemodialysis anaphylaxis].
    Honkanen E; Mäkelä P; Björksten F; Salo OP; Grönhagen-Riska C
    Duodecim; 1987; 103(11):694-9. PubMed ID: 3454322
    [No Abstract]   [Full Text] [Related]  

  • 26. [Allergic risks of hemodialysis. Results of an allergologic investigation in 138 patients].
    Kessler M; Moneret-Vautrin AD; Mariot A; Cao HT; Chanliau J; Guéant JL; Nicolas JP
    Nephrologie; 1990; 11(4):249-54. PubMed ID: 2074927
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Anaphylactoid reactions in dialysis patients: role of ethylene-oxide.
    Bommer J; Wilhelms OH; Barth HP; Schindele H; Ritz E
    Lancet; 1985 Dec 21-28; 2(8469-70):1382-5. PubMed ID: 2867391
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Hypersensitivity reactions during haemodialysis: role of complement fragments and ethylene oxide antibodies.
    Lemke HD; Heidland A; Schaefer RM
    Nephrol Dial Transplant; 1990; 5(4):264-9. PubMed ID: 2113222
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Hemodialysis eosinophilia.
    Novello AC; Port FK
    Int J Artif Organs; 1982 Jan; 5(1):5-7. PubMed ID: 6926751
    [No Abstract]   [Full Text] [Related]  

  • 30. Hypersensitivity reactions to ethylene oxide: clinical experience.
    Masin G; Polenaković M; Ivanovski N; Atanasov N; Olivera S; Cakalaroski K
    Nephrol Dial Transplant; 1991; 6 Suppl 3():50-2. PubMed ID: 1775268
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ethylene oxide (ETO) as a possible cause of an allergic reaction during peritoneal dialysis and immunologic detection of ETO from dialysis tubing.
    Patterson R; Lerner C; Roberts M; Moel D; Grammer LC
    Am J Kidney Dis; 1986 Jul; 8(1):64-6. PubMed ID: 3728464
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Reduction of allergic reactions in patients undergoing long-term hemodialysis.
    Cavaillon JM; Poignet JL; Fitting C; Delons S; David B
    J Allergy Clin Immunol; 1993 Aug; 92(2):355-7. PubMed ID: 8349945
    [No Abstract]   [Full Text] [Related]  

  • 33. IgE against ethylene oxide-altered human serum albumin (ETO-HSA) as an etiologic agent in allergic reactions of hemodialysis patients.
    Grammer LC; Patterson R
    Artif Organs; 1987 Apr; 11(2):97-9. PubMed ID: 3593052
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Residual ethylene oxide in hollow-fiber dialyzers.
    Henne W; Dietrich W; Pelger M; von Sengbusch G
    Artif Organs; 1984 Aug; 8(3):306-10. PubMed ID: 6477198
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Side effects due to materials used in hemodialysis equipment.
    Bommer J; Ritz E; Andrassy K
    Adv Nephrol Necker Hosp; 1985; 14():409-38. PubMed ID: 3919542
    [No Abstract]   [Full Text] [Related]  

  • 36. [Ethylene oxide-induced antibodies and hypersensitivity reactions in hemodialysis].
    Watschinger BH; Graf H; Kovarik J; Jarisch R; Leitner E; Stummvoll HK; Watschinger B
    Wien Med Wochenschr; 1988 Mar; 138(5):110-2. PubMed ID: 3388873
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The possible role of Limulus-amebocyte-lysate-reactive material in hemodialysis. First-use syndrome.
    Pearson FC
    Blood Purif; 1987; 5(2-3):115-22. PubMed ID: 3620119
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Allergy to a product(s) of ethylene oxide gas: demonstration of IgE and IgG antibodies and hapten specificity.
    Dolovich J; Bell B
    J Allergy Clin Immunol; 1978 Jul; 62(1):30-2. PubMed ID: 307011
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Ethylene oxide sterilisation of dialysis equipment.
    Hoenich NA; Woffindin C; Ward MK
    Lancet; 1986 Jun; 1(8496):1498. PubMed ID: 2873304
    [No Abstract]   [Full Text] [Related]  

  • 40. [Sensitization to ethylene oxide: a possible cause of reactions in hemodialysis patients].
    Tosoni C; Apollonio A; Carabellese N; Cattaneo R; Soldati F; Campanini M; Castiglione A; Scalia P; Romagnani M; Sorgato G
    Boll Ist Sieroter Milan; 1990; 69(1):339-42. PubMed ID: 2102117
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.