BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 34431220)

  • 1. 2021 update of the 2012 ICSH Recommendations for identification, diagnostic value, and quantitation of schistocytes: Impact and revisions.
    Zini G; d'Onofrio G; Erber WN; Lee SH; Nagai Y; Basak GW; Lesesve JF;
    Int J Lab Hematol; 2021 Dec; 43(6):1264-1271. PubMed ID: 34431220
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Clinical Significance of Schistocytes: A Prospective Evaluation of the International Council for Standardization in Hematology Schistocyte Guidelines.
    Schapkaitz E; Mezgebe MH
    Turk J Haematol; 2017 Mar; 34(1):59-63. PubMed ID: 27795225
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fragmented red blood cells automated measurement is a useful parameter to exclude schistocytes on the blood film.
    Lesesve JF; Asnafi V; Braun F; Zini G
    Int J Lab Hematol; 2012 Dec; 34(6):566-76. PubMed ID: 22694255
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An evaluation of existing manual blood film schistocyte quantitation guidelines and a new proposed method.
    Noutsos T; Laidman AY; Survela L; Arvanitis D; Segalla R; Brown SG; Isbister GK
    Pathology; 2021 Oct; 53(6):746-752. PubMed ID: 33863504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated Quantification of Fragmented Red Blood Cells: Neonatal Reference Intervals and Clinical Disorders of Neonatal Intensive Care Unit Patients with High Values.
    Judkins AJ; MacQueen BC; Christensen RD; Henry E; Snow GL; Bennett ST
    Neonatology; 2019; 115(1):5-12. PubMed ID: 30184540
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Traversing Their Path to the Peripheral Smear: The Journey of Traumatized Red Blood Cells.
    Mannem C; Saher T; Ramdas GB
    J Lab Physicians; 2023 Sep; 15(3):437-442. PubMed ID: 37564225
    [No Abstract]   [Full Text] [Related]  

  • 7. ICSH recommendations for identification, diagnostic value, and quantitation of schistocytes.
    Zini G; d'Onofrio G; Briggs C; Erber W; Jou JM; Lee SH; McFadden S; Vives-Corrons JL; Yutaka N; Lesesve JF;
    Int J Lab Hematol; 2012 Apr; 34(2):107-16. PubMed ID: 22081912
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microscopic schistocyte determination according to International Council for Standardization in Hematology recommendations in various diseases.
    Huh HJ; Chung JW; Chae SL
    Int J Lab Hematol; 2013 Oct; 35(5):542-7. PubMed ID: 23480787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Schistocytes in disseminated intravascular coagulation.
    Lesesve JF; Martin M; Banasiak C; André-Kerneïs E; Bardet V; Lusina D; Kharbach A; Geneviève F; Lecompte T
    Int J Lab Hematol; 2014 Aug; 36(4):439-43. PubMed ID: 24261329
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Evaluation of schistocytes measurement guidelines].
    Lesesve JF; Crepin O; Siest JP; Régnier F; Zeltner S
    Ann Biol Clin (Paris); 2012 Oct; 70(5):605-13. PubMed ID: 23047908
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neonates with suspected microangiopathic disorders: performance of standard manual schistocyte enumeration vs. the automated fragmented red cell count.
    Bahr TM; Judkins AJ; Christensen RD; Baer VL; Henry E; Minton SD; Gerday E; Bennett ST
    J Perinatol; 2019 Nov; 39(11):1555-1561. PubMed ID: 31462723
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Peripheral blood schistocytes in the acute phase after allogeneic or autologous stem cell transplantation assessed by digital microscopy.
    Karakioulaki M; Martinez M; Medinger M; Heim D; Passweg JR; Tsakiris DA
    Int J Lab Hematol; 2020 Apr; 42(2):145-151. PubMed ID: 31769937
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of ICSH schistocyte measurement guidelines in France.
    Lesesve JF; El Adssi H; Watine J; Oosterhuis W; Régnier F
    Int J Lab Hematol; 2013 Dec; 35(6):601-7. PubMed ID: 23601189
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fragmented red cells reference range (Sysmex XN(®) automated blood cell counter).
    Lesesve JF; Daigney A; Henry S; Speyer E
    Ann Biol Clin (Paris); 2015; 73(5):547-56. PubMed ID: 26489813
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fragmented red cells reference range for the Sysmex XN®-series of automated blood cell counters.
    Lesesve JF; Speyer E; Perol JP
    Int J Lab Hematol; 2015 Oct; 37(5):583-7. PubMed ID: 25882632
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modification of the Algorithm Used by Automated Hematology Analyzer XN-3000 Improves Specificity in the Detection of Schistocytes.
    Hisasue M; Ai T; Kimura K; Matsuzaki A; Nishibe K; Tabe Y; Ohsaka A
    Clin Lab; 2021 Jan; 67(1):. PubMed ID: 33491415
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Reproductibility of the morphological identification of schisocytes and evaluation of non observer-dependent methods].
    Lesesve JF; Lecompte T; Alla F; Fenneteau O; Cynober T; Siest JP; Troussard X; Flandrin G;
    Ann Biol Clin (Paris); 2005; 63(3):279-89. PubMed ID: 15951259
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Schistocyte quantitation, thrombotic microangiopathy and acute kidney injury in Australian snakebite coagulopathy [ASP28].
    Noutsos T; Currie BJ; Brown SG; Isbister GK
    Int J Lab Hematol; 2021 Oct; 43(5):959-965. PubMed ID: 33615713
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Autoimmune thrombotic microangiopathy: advances in pathogenesis, diagnosis, and management.
    Tsai HM
    Semin Thromb Hemost; 2012 Jul; 38(5):469-82. PubMed ID: 22473663
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of fragmented red cell (FRC) counting using Sysmex XE-5000 - does hypochromia play a role?
    Chalvatzi K; Spiroglou S; Nikolaidou A; Diza E
    Int J Lab Hematol; 2013 Apr; 35(2):193-9. PubMed ID: 23134354
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.