These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
148 related articles for article (PubMed ID: 34432821)
1. Ventilator output splitting interface 'ACRA': Description and evaluation in lung simulators and in an experimental ARDS animal model. Otero PE; Tarragona L; Zaccagnini AS; Verdier N; Ceballos MR; Gogniat E; Cabaleiro JM; D'Adamo J; Duriez T; Eijo PG; Artana G PLoS One; 2021; 16(8):e0256469. PubMed ID: 34432821 [TBL] [Abstract][Full Text] [Related]
2. Shared Ventilation in the Era of COVID-19: A Theoretical Consideration of the Dangers and Potential Solutions. Herrmann J; Fonseca da Cruz A; Hawley ML; Branson RD; Kaczka DW Respir Care; 2020 Jul; 65(7):932-945. PubMed ID: 32376612 [TBL] [Abstract][Full Text] [Related]
3. Multiplex Ventilation: Solutions for Four Main Safety Problems. Sorg ME; Branson RD; Hatipoğlu U; Chatburn RL Respir Care; 2021 Jul; 66(7):1074-1086. PubMed ID: 33906955 [TBL] [Abstract][Full Text] [Related]
4. Computational simulation to assess patient safety of uncompensated COVID-19 two-patient ventilator sharing using the Pulse Physiology Engine. Webb JB; Bray A; Asare PK; Clipp RB; Mehta YB; Penupolu S; Patel AA; Poler SM PLoS One; 2020; 15(11):e0242532. PubMed ID: 33237927 [TBL] [Abstract][Full Text] [Related]
5. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
6. Design of a flow modulation device to facilitate individualized ventilation in a shared ventilator setup. Stiers M; Vercauteren J; Schepens T; Mergeay M; Janssen L; Hoogmartens O; Neyrinck A; Marinus BG; Sabbe M J Clin Monit Comput; 2024 Jun; 38(3):679-690. PubMed ID: 38557919 [TBL] [Abstract][Full Text] [Related]
7. Bench performance of ventilators during simulated paediatric ventilation. Park MA; Freebairn RC; Gomersall CD Anaesth Intensive Care; 2013 May; 41(3):349-58. PubMed ID: 23659397 [TBL] [Abstract][Full Text] [Related]
8. Individualized mechanical ventilation in a shared ventilator setting: limits, safety and technical details. Stiers M; Mergeay M; Pinson H; Janssen L; Voets E; De Cauwer H; Schepens T J Clin Monit Comput; 2021 Dec; 35(6):1299-1309. PubMed ID: 33025322 [TBL] [Abstract][Full Text] [Related]
9. Coping with COVID-19: ventilator splitting with differential driving pressures using standard hospital equipment. Clarke AL; Stephens AF; Liao S; Byrne TJ; Gregory SD Anaesthesia; 2020 Jul; 75(7):872-880. PubMed ID: 32271942 [TBL] [Abstract][Full Text] [Related]
10. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
11. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator]. Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078 [TBL] [Abstract][Full Text] [Related]
12. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment]. Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533 [TBL] [Abstract][Full Text] [Related]
13. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury. Custer JW; Watson CM; Dwyer J; Kaczka DW; Simon BA; Easley RB Pediatr Crit Care Med; 2011 Nov; 12(6):e357-61. PubMed ID: 21317679 [TBL] [Abstract][Full Text] [Related]
14. Reliability of Tidal Volume in Average Volume Assured Pressure Support Mode. Stagnara A; Baboi L; Nesme P; Subtil F; Louis B; Guérin C Respir Care; 2018 Sep; 63(9):1139-1146. PubMed ID: 29921607 [TBL] [Abstract][Full Text] [Related]
15. Selecting ventilator settings according to variables derived from the quasi-static pressure/volume relationship in patients with acute lung injury. Putensen C; Baum M; Hörmann C Anesth Analg; 1993 Sep; 77(3):436-47. PubMed ID: 8368542 [TBL] [Abstract][Full Text] [Related]
16. Independent lung ventilation with a single ventilator using a variable resistance valve. Charan NB; Carvalho CG; Hawk P; Crowley JJ; Carvalho P Chest; 1995 Jan; 107(1):256-60. PubMed ID: 7813287 [TBL] [Abstract][Full Text] [Related]
17. Volume-Targeted Ventilation in the Neonate: Benchmarking Ventilators on an Active Lung Model. Krieger TJ; Wald M Pediatr Crit Care Med; 2017 Mar; 18(3):241-248. PubMed ID: 28121833 [TBL] [Abstract][Full Text] [Related]
18. PEEP/ FIO2 ARDSNet Scale Grouping of a Single Ventilator for Two Patients: Modeling Tidal Volume Response. Kheyfets VO; Lammers SR; Wagner J; Bartels K; Piccoli J; Smith BJ Respir Care; 2020 Aug; 65(8):1094-1103. PubMed ID: 32712582 [TBL] [Abstract][Full Text] [Related]
19. Rationale, study design and analysis plan of the lung imaging morphology for ventilator settings in acute respiratory distress syndrome study (LIVE study): Study protocol for a randomised controlled trial. Jabaudon M; Godet T; Futier E; Bazin JÉ; Sapin V; Roszyk L; Pereira B; Constantin JM; Anaesth Crit Care Pain Med; 2017 Oct; 36(5):301-306. PubMed ID: 28323236 [TBL] [Abstract][Full Text] [Related]
20. Ventilator-related causes of lung injury: the mechanical power. Gattinoni L; Tonetti T; Cressoni M; Cadringher P; Herrmann P; Moerer O; Protti A; Gotti M; Chiurazzi C; Carlesso E; Chiumello D; Quintel M Intensive Care Med; 2016 Oct; 42(10):1567-1575. PubMed ID: 27620287 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]