BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 34437590)

  • 1. Point-of-care microvolume cytometer measures platelet counts with high accuracy from capillary blood.
    Dickerson WM; Yu R; Westergren HU; Paraskos J; Schatz P; Tigerstrom A; Ekman A; Sánchez J; Cheng J; Li L; Chan EY
    PLoS One; 2021; 16(8):e0256423. PubMed ID: 34437590
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Platelet counting by the RBC/platelet ratio method. A reference method.
    ;
    Am J Clin Pathol; 2001 Mar; 115(3):460-4. PubMed ID: 11246942
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of platelet counting accuracy with the celltac f automated hematology analyzer.
    Nagai Y; Kondo H; Tatsumi N
    J Autom Methods Manag Chem; 2005; 2005(4):235-9. PubMed ID: 18924739
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of venous and capillary differential leukocyte counts using a standard hematology analyzer and a novel microfluidic impedance cytometer.
    Hollis VS; Holloway JA; Harris S; Spencer D; van Berkel C; Morgan H
    PLoS One; 2012; 7(9):e43702. PubMed ID: 23028467
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of platelet counting of Abbott Alinity hq and Sysmex XN-9000 automated hematology analyzer compared with international reference method.
    Kim HY; Bang SH; Cho D; Kim HJ; Kim SH
    Int J Lab Hematol; 2021 Jun; 43(3):387-394. PubMed ID: 33217153
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of flow cytometry with the Sysmex XT2000iV automated analyzer for the detection of reticulated platelets in dogs.
    Pankraz A; Bauer N; Moritz A
    Vet Clin Pathol; 2009 Mar; 38(1):30-8. PubMed ID: 19228361
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New fluorescent method (PLT-F) on Sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting.
    Schoorl M; Schoorl M; Oomes J; van Pelt J
    Am J Clin Pathol; 2013 Oct; 140(4):495-9. PubMed ID: 24045545
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Platelet counting with the BD Accuri(TM) C6 flow cytometer.
    Masters A; Harrison P
    Platelets; 2014; 25(3):175-80. PubMed ID: 23772865
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance evaluation of a novel platelet count parameter, hybrid platelet count, on the BC-780 automated hematology analyzer.
    Prompetchara E; Parnsamut C; Chirapanuruk A; Ketloy C
    Clin Chem Lab Med; 2024 Mar; 62(4):690-697. PubMed ID: 37855253
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers.
    Tanaka Y; Tanaka Y; Gondo K; Maruki Y; Kondo T; Asai S; Matsushita H; Miyachi H
    J Clin Lab Anal; 2014 Sep; 28(5):341-8. PubMed ID: 24648166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Compare the accuracy and precision of Coulter LH780, Mindray BC-6000 Plus, and Sysmex XN-9000 with the international reference flow cytometric method in platelet counting.
    Sun Y; Hu Z; Huang Z; Chen H; Qin S; Jianing Z; Chen S; Qin X; Ye Y; Wang C
    PLoS One; 2019; 14(5):e0217298. PubMed ID: 31125378
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Standardisation of platelet counting accuracy in blood banks by reference to an automated immunoplatelet procedure: comparative evaluation of Cell-Dyn CD4000 impedance and optical platelet counts.
    Johannessen B; Haugen T; Scott CS
    Transfus Apher Sci; 2001 Oct; 25(2):93-106. PubMed ID: 11761280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluation of PLT-H (hybrid-channel platelet) under various interferences and application studies for platelet transfusion decisions.
    Cai Q; Lin H; Guo P
    Platelets; 2023 Dec; 34(1):2287064. PubMed ID: 38031975
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative assessment of platelets, platelet microparticles, and platelet aggregates with flow cytometry.
    Matzdorff AC; Kühnel G; Kemkes-Matthes B; Pralle H
    J Lab Clin Med; 1998 Jun; 131(6):507-17. PubMed ID: 9626986
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assay validity of point-of-care platelet function tests in thrombocytopenic blood samples.
    Lacom C; Tolios A; Löffler MW; Eichelberger B; Quehenberger P; Schaden E; Wiegele M
    Biochem Med (Zagreb); 2022 Jun; 32(2):020713. PubMed ID: 35799989
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Drop-to-drop variation in the cellular components of fingerprick blood: implications for point-of-care diagnostic development.
    Bond MM; Richards-Kortum RR
    Am J Clin Pathol; 2015 Dec; 144(6):885-94. PubMed ID: 26572995
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation on clinical performance of the new low-value platelet measurement mode (PLT-8X) of BC-6800Plus.
    Shen Y; Liu D; Wang Y; Cao J; Zhang S; Wen H; Dong Q; Zheng D; Qiu J
    Ann Transl Med; 2022 Jun; 10(12):692. PubMed ID: 35845540
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Platelet counts in capillary blood.
    Feusner JH; Behrens JA; Detter JC; Cullen TC
    Am J Clin Pathol; 1979 Sep; 72(3):410-4. PubMed ID: 112854
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immunoplatelet counting: a proposed new reference procedure.
    Harrison P; Horton A; Grant D; Briggs C; MacHin S
    Br J Haematol; 2000 Feb; 108(2):228-35. PubMed ID: 10691847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance evaluation of BD FACSPresto™ point of care CD4 analyzer to enumerate CD4 counts for monitoring HIV infected individuals in Nigeria.
    Negedu-Momoh OR; Jegede FE; Yakubu A; Balogun O; Abdullahi M; Badru T; Oladele EA; Agbakwuru C; Khamofu H; Torpey K
    PLoS One; 2017; 12(5):e0178037. PubMed ID: 28542359
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.