BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 34437732)

  • 1. Macroscopic visible core length can predict the histological sample quantity in endoscopic ultrasound-guided tissue acquisition: Multicenter prospective study.
    Kaneko J; Ishiwatari H; Sasaki K; Yasuda I; Takahashi K; Imura J; Iwashita T; Uemura S; Hatano Y; Miyazaki T; Satoh T; Sato J; Ishikawa K
    Dig Endosc; 2022 Mar; 34(3):622-631. PubMed ID: 34437732
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study).
    Iwashita T; Yasuda I; Mukai T; Doi S; Nakashima M; Uemura S; Mabuchi M; Shimizu M; Hatano Y; Hara A; Moriwaki H
    Gastrointest Endosc; 2015 Jan; 81(1):177-85. PubMed ID: 25440688
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Factors of Endoscopic Ultrasound-Guided Tissue Acquisition for Successful Next-Generation Sequencing in Pancreatic Ductal Adenocarcinoma.
    Park JK; Lee JH; Noh DH; Park JK; Lee KT; Lee JK; Lee KH; Jang KT; Cho J
    Gut Liver; 2020 May; 14(3):387-394. PubMed ID: 31581388
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of 22-gauge standard and Franseen needles in EUS-guided tissue acquisition for diagnosing solid pancreatic lesions: a multicenter randomized controlled trial.
    Itonaga M; Yasukawa S; Fukutake N; Ogura T; Asada M; Shimokawa T; Inatomi O; Nakai Y; Shiomi H; Nebiki H; Suzuki A; Kitagawa K; Asai S; Shimatani M; Sanuki T; Kurita A; Takenaka M; Yoshida M; Hoki N; Yasuda H; Maruyama H; Matsumoto H; Yanagisawa A; Kitano M
    Gastrointest Endosc; 2022 Jul; 96(1):57-66.e2. PubMed ID: 35151711
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Macroscopic on-site evaluation of biopsy specimens for accurate pathological diagnosis during EUS-guided fine needle biopsy using 22-G Franseen needle.
    Kaneko J; Ishiwatari H; Sasaki K; Satoh T; Sato J; Matsubayashi H; Yabuuchi Y; Kishida Y; Yoshida M; Ito S; Kawata N; Imai K; Kakushima N; Takizawa K; Hotta K; Ono H
    Endosc Ultrasound; 2020; 9(6):385-391. PubMed ID: 32913149
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endoscopic Ultrasound-Guided Fine Needle Biopsy Using 22-Gauge Franseen Needle for the Histological Diagnosis of Solid Lesions: A Multicenter Prospective Pilot Study.
    Mita N; Iwashita T; Uemura S; Iwasa Y; Toda K; Mukai T; Miyazaki T; Yasuda I; Shimizu M
    Dig Dis Sci; 2020 Apr; 65(4):1155-1163. PubMed ID: 31531819
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multicenter prospective study of the efficacy of stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition in patients with pancreatic cancer.
    Watanabe M; Okuwaki K; Kida M; Imaizumi H; Matsumoto T; Iwai T; Hasegawa R; Masutani H; Kurosu T; Minato N; Tamaki A; Ishizaki J; Kusano C
    Pancreatology; 2022 Mar; 22(2):311-316. PubMed ID: 34969602
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
    Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
    Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of 22G standard and Franseen needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing pancreatic mass lesions: Study protocol for a controlled trial.
    Itonaga M; Yasukawa S; Shimokawa T; Takenaka M; Fukutake N; Ogura T; Sakagami J; Shiomi H; Okura Y; Inatomi O; Matsumoto H; Kurita A; Suzuki A; Tanaka K; Kitano M
    Trials; 2019 Dec; 20(1):816. PubMed ID: 31888733
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Histological diagnosis and grading of pancreatic neuroendocrine tumor by endoscopic ultrasound-guided fine needle biopsy using a 25-gauge needle with a core trap: A multicenter prospective trial.
    Kamata K; Ashida R; Yasukawa S; Chiba Y; Fukutake N; Nebiki H; Kurita A; Takaoka M; Ogura T; Shiomi H; Asada M; Yasuda H; Shigekawa M; Yanagisawa A; Kudo M; Kitano M
    Pancreatology; 2020 Oct; 20(7):1428-1433. PubMed ID: 32952043
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Endoscopic ultrasound-fine needle biopsies of pancreatic lesions: Prospective study of histology quality using Franseen needle.
    Stathopoulos P; Pehl A; Breitling LP; Bauer C; Grote T; Gress TM; Denkert C; Denzer UW
    World J Gastroenterol; 2020 Oct; 26(37):5693-5704. PubMed ID: 33088162
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic Lesions.
    Ishigaki K; Nakai Y; Oyama H; Kanai S; Suzuki T; Nakamura T; Sato T; Hakuta R; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Kogure H; Tada M; Isayama H; Koike K
    Gut Liver; 2020 Nov; 14(6):817-825. PubMed ID: 32457276
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Macroscopic on‑site quality evaluation of biopsy specimens to improve the diagnostic accuracy of endoscopic ultrasound‑guided fine needle aspiration using a 22‑gauge needle for solid lesions: A single‑center retrospective study.
    Guan C; Wu M; Ye J; Liu Z; Mao Z; Lu C; Zhang J
    Exp Ther Med; 2023 Jul; 26(1):338. PubMed ID: 37383379
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endoscopic ultrasonography-guided biopsy using a Franseen needle design: Initial assessment.
    Bang JY; Hebert-Magee S; Hasan MK; Navaneethan U; Hawes R; Varadarajulu S
    Dig Endosc; 2017 May; 29(3):338-346. PubMed ID: 27878861
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endoscopic ultrasound fine needle aspiration
    Levine I; Trindade AJ
    World J Gastroenterol; 2021 Jul; 27(26):4194-4207. PubMed ID: 34326619
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of visual on-site evaluation (Vose) In predicting the adequacy of Eus-guided fine needle biopsy: A single center prospective study.
    Stigliano S; Balassone V; Biasutto D; Covotta F; Signoretti M; Di Matteo FM
    Pancreatology; 2021 Jan; 21(1):312-317. PubMed ID: 33358086
    [TBL] [Abstract][Full Text] [Related]  

  • 17. EUS-guided core biopsies of pancreatic solid masses using a new fork-tip needle: A multicenter prospective study.
    Di Leo M; Crinò SF; Bernardoni L; Rahal D; Auriemma F; Correale L; Donato G; Massidda M; Anderloni A; Manfrin E; Armellini E; Poliani L; Fugazza A; Semeraro R; Occhipinti P; Repici A; Carrara S
    Dig Liver Dis; 2019 Sep; 51(9):1275-1280. PubMed ID: 31010744
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A prospective multicenter study of endoscopic ultrasound-guided fine needle biopsy using a 22-gauge Franseen needle for pancreatic solid lesions.
    Ishigaki K; Nakai Y; Sasahira N; Sugimori K; Kitamura K; Iwai T; Matsubara S; Shimura K; Itoi T; Ryozawa S; Ushio J; Doi S; Imazu H; Maetani I; Isayama H;
    J Gastroenterol Hepatol; 2021 Oct; 36(10):2754-2761. PubMed ID: 33939863
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized trial comparing the 25G and 22G Franseen needles in endoscopic ultrasound-guided tissue acquisition from solid pancreatic masses for adequate histological assessment.
    Tomoda T; Kato H; Fujii Y; Yamazaki T; Matsumoto K; Horiguchi S; Tsutsumi K; Inoue H; Tanaka T; Mitsuhashi T; Okada H
    Dig Endosc; 2022 Mar; 34(3):596-603. PubMed ID: 34245614
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 22-gauge core
    Sterlacci W; Sioulas AD; Veits L; Gönüllü P; Schachschal G; Groth S; Anders M; Kontos CK; Topalidis T; Hinsch A; Vieth M; Rösch T; Denzer UW
    World J Gastroenterol; 2016 Oct; 22(39):8820-8830. PubMed ID: 27818598
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.