These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 34442218)

  • 21. Implementing a negative-pressure isolation ward for a surge in airborne infectious patients.
    Miller SL; Clements N; Elliott SA; Subhash SS; Eagan A; Radonovich LJ
    Am J Infect Control; 2017 Jun; 45(6):652-659. PubMed ID: 28330710
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards.
    Weng CL; Kau LJ
    J Healthc Eng; 2021; 2021():8872167. PubMed ID: 33833861
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of rooms with negative pressure ventilation used for respiratory isolation in seven midwestern hospitals.
    Fraser VJ; Johnson K; Primack J; Jones M; Medoff G; Dunagan WC
    Infect Control Hosp Epidemiol; 1993 Nov; 14(11):623-8. PubMed ID: 8132981
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Identification of factors that disrupt negative air pressurization of respiratory isolation rooms.
    Pavelchak N; DePersis RP; London M; Stricof R; Oxtoby M; DiFerdinando G; Marshall E
    Infect Control Hosp Epidemiol; 2000 Mar; 21(3):191-5. PubMed ID: 10738988
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Aerodynamic performance of a ventilation system for droplet control by coughing in a hospital isolation ward.
    Song Y; Yang C; Li H; Chen H; Shen S; Hou Y; Wang J
    Environ Sci Pollut Res Int; 2023 Jun; 30(29):73812-73824. PubMed ID: 37195609
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Directional Airflow and Ventilation in Hospitals: A Case Study of Secondary Airborne Infection.
    Mousavi ES; Grosskopf KR
    Energy Procedia; 2015 Nov; 78():1201-1206. PubMed ID: 32288886
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Natural ventilation for the prevention of airborne contagion.
    Escombe AR; Oeser CC; Gilman RH; Navincopa M; Ticona E; Pan W; Martínez C; Chacaltana J; Rodríguez R; Moore DA; Friedland JS; Evans CA
    PLoS Med; 2007 Feb; 4(2):e68. PubMed ID: 17326709
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Adaptive Wall-Based Attachment Ventilation: A Comparative Study on Its Effectiveness in Airborne Infection Isolation Rooms with Negative Pressure.
    Zhang Y; Han O; Li A; Hou L; Olofsson T; Zhang L; Lei W
    Engineering (Beijing); 2022 Jan; 8():130-137. PubMed ID: 33520328
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluating the control of tuberculosis among healthcare workers: adherence to CDC guidelines of three urban hospitals in California.
    Sutton PM; Nicas M; Reinisch F; Harrison RJ
    Infect Control Hosp Epidemiol; 1998 Jul; 19(7):487-93. PubMed ID: 9702570
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Hospital and community acquired infection and the built environment--design and testing of infection control rooms.
    Walker JT; Hoffman P; Bennett AM; Vos MC; Thomas M; Tomlinson N
    J Hosp Infect; 2007 Jun; 65 Suppl 2():43-9. PubMed ID: 17540241
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A computer evaluation of ventilation performance in a negative-pressure operating theater.
    Chow TT; Kwan A; Lin Z; Bai W
    Anesth Analg; 2006 Oct; 103(4):913-8. PubMed ID: 17000803
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A novel circulated air curtain system to confine the transmission of exhaled contaminants: A numerical and experimental investigation.
    Wang H; Qian H; Zhou R; Zheng X
    Build Simul; 2020; 13(6):1425-1437. PubMed ID: 32837692
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dynamic airflow simulation within an isolation room.
    Shih YC; Chiu CC; Wang O
    Build Environ; 2007 Sep; 42(9):3194-3209. PubMed ID: 32287999
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The ventilation of multiple-bed hospital wards: review and analysis.
    Beggs CB; Kerr KG; Noakes CJ; Hathway EA; Sleigh PA
    Am J Infect Control; 2008 May; 36(4):250-9. PubMed ID: 18455045
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Natural ventilation for reducing airborne infection in hospitals.
    Qian H; Li Y; Seto WH; Ching P; Ching WH; Sun HQ
    Build Environ; 2010 Mar; 45(3):559-565. PubMed ID: 32288008
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hospital ventilation simulation for the study of potential exposure to contaminants.
    Balocco C
    Build Simul; 2011; 4(1):5-20. PubMed ID: 32218908
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Tuberculosis isolation: comparison of written procedures and actual practices in three California hospitals.
    Sutton PM; Nicas M; Harrison RJ
    Infect Control Hosp Epidemiol; 2000 Jan; 21(1):28-32. PubMed ID: 10656351
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A simple and inexpensive method for determining the effective ventilation rate in a negatively pressurized room using airborne particles as a tracer.
    Pavelchak N; Palmer W; DePersis RP; London MA
    Appl Occup Environ Hyg; 2002 Oct; 17(10):704-10. PubMed ID: 12363211
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Using computational fluid dynamics modeling to evaluate the design of hospital ultraviolet germicidal irradiation systems for inactivating airborne mycobacteria.
    Xu P; Fisher N; Miller SL
    Photochem Photobiol; 2013; 89(4):792-8. PubMed ID: 23418820
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Environmental contamination in the isolation rooms of COVID-19 patients with severe pneumonia requiring mechanical ventilation or high-flow oxygen therapy.
    Ahn JY; An S; Sohn Y; Cho Y; Hyun JH; Baek YJ; Kim MH; Jeong SJ; Kim JH; Ku NS; Yeom JS; Smith DM; Lee H; Yong D; Lee YJ; Kim JW; Kim HR; Hwang J; Choi JY
    J Hosp Infect; 2020 Nov; 106(3):570-576. PubMed ID: 32828864
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.