BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 34460513)

  • 1. A Computational Study on Temperature Variations in MRgFUS Treatments Using PRF Thermometry Techniques and Optical Probes.
    Militello C; Rundo L; Vicari F; Agnello L; Borasi G; Vitabile S; Russo G
    J Imaging; 2021 Mar; 7(4):. PubMed ID: 34460513
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs.
    Grissom WA; Rieke V; Holbrook AB; Medan Y; Lustig M; Santos J; McConnell MV; Pauly KB
    Med Phys; 2010 Sep; 37(9):5014-26. PubMed ID: 20964221
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Proton resonance frequency-based thermometry for aqueous and adipose tissues.
    Zong S; Shen G; Mei CS
    Med Phys; 2021 Oct; 48(10):5651-5660. PubMed ID: 34468019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anatomic thermochromic tissue-mimicking phantom of the lumbar spine for pre-clinical evaluation of MR-guided focused ultrasound (MRgFUS) ablation of the facet joint.
    Zhang W; Trivedi H; Adams M; Losey AD; Diederich CJ; Ozhinsky E; Rieke V; Bucknor MD
    Int J Hyperthermia; 2021; 38(1):130-135. PubMed ID: 33541151
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A variable flip angle golden-angle-ordered 3D stack-of-radial MRI technique for simultaneous proton resonant frequency shift and T
    Zhang L; Armstrong T; Li X; Wu HH
    Magn Reson Med; 2019 Dec; 82(6):2062-2076. PubMed ID: 31257639
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Referenceless magnetic resonance temperature imaging using Gaussian process modeling.
    Yung JP; Fuentes D; MacLellan CJ; Maier F; Liapis Y; Hazle JD; Stafford RJ
    Med Phys; 2017 Jul; 44(7):3545-3555. PubMed ID: 28317125
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Thermometry during MR-guided focused ultrasound in a preclinical model based on Thiel embalmed tissue.
    Karakitsios I; Bobeica M; Saliev T; Rube M; Melzer A
    Minim Invasive Ther Allied Technol; 2014 Mar; 23(2):120-6. PubMed ID: 24079349
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.
    Bing C; Staruch RM; Tillander M; Köhler MO; Mougenot C; Ylihautala M; Laetsch TW; Chopra R
    Int J Hyperthermia; 2016 Sep; 32(6):673-87. PubMed ID: 27210733
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prolonged heating in nontargeted tissue during MR-guided focused ultrasound of bone tumors.
    Bitton RR; Webb TD; Pauly KB; Ghanouni P
    J Magn Reson Imaging; 2019 Nov; 50(5):1526-1533. PubMed ID: 30950554
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids.
    McDannold N; Tempany C; Jolesz F; Hynynen K
    J Magn Reson Imaging; 2008 Oct; 28(4):1026-32. PubMed ID: 18821603
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reference-less MR thermometry on pre-clinical thiel human cadaver for liver surgery with MRgFUS.
    Karakitsios I; Mihcin S; Melzer A
    Minim Invasive Ther Allied Technol; 2019 Feb; 28(1):15-21. PubMed ID: 29764258
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A T1-based correction method for proton resonance frequency shift thermometry in breast tissue.
    McLean M; Parker DL; Odéen H; Payne A
    Med Phys; 2021 Sep; 48(9):4719-4729. PubMed ID: 34265109
    [TBL] [Abstract][Full Text] [Related]  

  • 14. MRI monitoring of focused ultrasound sonications near metallic hardware.
    Weber H; Ghanouni P; Pascal-Tenorio A; Pauly KB; Hargreaves BA
    Magn Reson Med; 2018 Jul; 80(1):259-271. PubMed ID: 29215150
    [TBL] [Abstract][Full Text] [Related]  

  • 15. MR techniques for guiding high-intensity focused ultrasound (HIFU) treatments.
    Kuroda K
    J Magn Reson Imaging; 2018 Feb; 47(2):316-331. PubMed ID: 28580706
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Magnetic resonance thermometry and its biological applications - Physical principles and practical considerations.
    Odéen H; Parker DL
    Prog Nucl Magn Reson Spectrosc; 2019 Feb; 110():34-61. PubMed ID: 30803693
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
    Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
    Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo evaluation of a breast-specific magnetic resonance guided focused ultrasound system in a goat udder model.
    Payne A; Todd N; Minalga E; Wang Y; Diakite M; Hadley R; Merrill R; Factor R; Neumayer L; Parker DL
    Med Phys; 2013 Jul; 40(7):073302. PubMed ID: 23822456
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transcranial magnetic resonance-guided focused ultrasound surgery for trigeminal neuralgia: a cadaveric and laboratory feasibility study.
    Monteith SJ; Medel R; Kassell NF; Wintermark M; Eames M; Snell J; Zadicario E; Grinfeld J; Sheehan JP; Elias WJ
    J Neurosurg; 2013 Feb; 118(2):319-28. PubMed ID: 23157185
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative MR thermometry based on phase-drift correction PRF shift method at 0.35 T.
    Chen Y; Ge M; Ali R; Jiang H; Huang X; Qiu B
    Biomed Eng Online; 2018 Apr; 17(1):39. PubMed ID: 29631576
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.