These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 34468838)

  • 1. Accurate placement of parieto-occipital shunt ventricular catheter: use of craniometrics and technical note.
    Li Ching Ng A; Kohan S
    Childs Nerv Syst; 2021 Oct; 37(10):3209-3217. PubMed ID: 34468838
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Outcome of Proximal Ventricular Catheter Placement in Ventriculoperitoneal Shunt Operations using the Parietal Approach.
    Ananthanandorn A
    J Med Assoc Thai; 2017 Feb; 100 Suppl 1():S27-32. PubMed ID: 29927173
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Change in ventricular size and effect of ventricular catheter placement in pediatric patients with shunted hydrocephalus.
    Tuli S; O'Hayon B; Drake J; Clarke M; Kestle J
    Neurosurgery; 1999 Dec; 45(6):1329-33; discussion 1333-5. PubMed ID: 10598700
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Factors associated with ventricular catheter movement and inaccurate catheter location: post hoc analysis of the hydrocephalus clinical research network ultrasound-guided shunt placement study.
    Whitehead WE; Riva-Cambrin J; Wellons JC; Kulkarni AV; Browd S; Limbrick D; Rozzelle C; Tamber MS; Simon TD; Shannon CN; Holubkov R; Oakes WJ; Luerssen TG; Walker ML; Drake JM; Kestle JR;
    J Neurosurg Pediatr; 2014 Aug; 14(2):173-8. PubMed ID: 24926971
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Freehand stereotactic ventricular catheter insertion for ventriculoperitoneal shunts based on individualized radio-anatomical landmarks.
    Spitaels J; Riva M; Delpierre I; Dewitte O; Bruneau M
    Acta Neurochir (Wien); 2021 Apr; 163(4):1103-1112. PubMed ID: 33587186
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ventricular catheter entry site and not catheter tip location predicts shunt survival: a secondary analysis of 3 large pediatric hydrocephalus studies.
    Whitehead WE; Riva-Cambrin J; Kulkarni AV; Wellons JC; Rozzelle CJ; Tamber MS; Limbrick DD; Browd SR; Naftel RP; Shannon CN; Simon TD; Holubkov R; Illner A; Cochrane DD; Drake JM; Luerssen TG; Oakes WJ; Kestle JR;
    J Neurosurg Pediatr; 2017 Feb; 19(2):157-167. PubMed ID: 27813457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using a burr hole valve prevents proximal shunt failure in infants and toddlers.
    Hsu CH; Chou SC; Yang SH; Shih MC; Kuo MF
    J Neurosurg Pediatr; 2019 Sep; 24(3):315-322. PubMed ID: 31252383
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Shortening of ventricular shunt catheter associated with cranial growth: effect of the frontal and parieto-occipital access route on long-term shunt patency.
    Nakahara K; Shimizu S; Utsuki S; Suzuki S; Oka H; Yamada M; Kan S; Fujii K
    Childs Nerv Syst; 2009 Jan; 25(1):91-4. PubMed ID: 18769926
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound-guided placement of ventricular catheters in first-time pediatric VP shunt surgery.
    Kullmann M; Khachatryan M; Schuhmann MU
    Childs Nerv Syst; 2018 Mar; 34(3):465-471. PubMed ID: 29167995
    [TBL] [Abstract][Full Text] [Related]  

  • 10. No significant improvement in the rate of accurate ventricular catheter location using ultrasound-guided CSF shunt insertion: a prospective, controlled study by the Hydrocephalus Clinical Research Network.
    Whitehead WE; Riva-Cambrin J; Wellons JC; Kulkarni AV; Holubkov R; Illner A; Oakes WJ; Luerssen TG; Walker ML; Drake JM; Kestle JR;
    J Neurosurg Pediatr; 2013 Dec; 12(6):565-74. PubMed ID: 24116981
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasound-Guided Insertion of the Ventricular Catheter in Ventriculoperitoneal Shunt Surgery: Evaluation of Accuracy and Feasibility in a Prospective Cohort.
    Leu S; Kamenova M; Mariani L; Soleman J
    J Neurol Surg A Cent Eur Neurosurg; 2021 Jan; 82(1):9-17. PubMed ID: 32968996
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study.
    Hayhurst C; Beems T; Jenkinson MD; Byrne P; Clark S; Kandasamy J; Goodden J; Nandoe Tewarie RD; Mallucci CL
    J Neurosurg; 2010 Dec; 113(6):1273-8. PubMed ID: 20397892
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates.
    Jung N; Kim D
    J Korean Neurosurg Soc; 2013 Mar; 53(3):150-4. PubMed ID: 23634264
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accurate placement of coronal ventricular catheter using stereotactic coordinate-guided free-hand passage. Technical note.
    Pang D; Grabb PA
    J Neurosurg; 1994 Apr; 80(4):750-5. PubMed ID: 8151359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship between the location of the ventricular catheter tip and the ventriculoperitoneal shunt malfunction.
    Dobran M; Nasi D; Mancini F; Gladi M; Polonara G; Marini A; Lattanzi S; Scerrati M
    Clin Neurol Neurosurg; 2018 Dec; 175():50-53. PubMed ID: 30366188
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laparoscopic versus open insertion of the peritoneal catheter in ventriculoperitoneal shunt placement: review of 810 consecutive cases.
    Naftel RP; Argo JL; Shannon CN; Taylor TH; Tubbs RS; Clements RH; Harrigan MR
    J Neurosurg; 2011 Jul; 115(1):151-8. PubMed ID: 21314272
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative ultrasound guidance for the placement of permanent ventricular cerebrospinal fluid shunt catheters: a single-center historical cohort study.
    Crowley RW; Dumont AS; Asthagiri AR; Torner JC; Medel R; Jane JA; Jane JA; Kassell NF
    World Neurosurg; 2014 Feb; 81(2):397-403. PubMed ID: 23321382
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Manual occipital ventricular puncture for cerebrospinal fluid shunt surgery: can aiming be standardized?
    Shimizu S; Tanaka R; Iida H; Fujii K
    Neurol Med Chir (Tokyo); 2004 Jul; 44(7):353-7; discussion 358. PubMed ID: 15347211
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the accuracy and proximal shunt failure rate of freehand placement versus intraoperative guidance in parietooccipital ventricular catheter placement.
    Wilson TJ; McCoy KE; Al-Holou WN; Molina SL; Smyth MD; Sullivan SE
    Neurosurg Focus; 2016 Sep; 41(3):E10. PubMed ID: 27581306
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electromagnetic-guided neuronavigation for safe placement of intraventricular catheters in pediatric neurosurgery.
    Hermann EJ; Capelle HH; Tschan CA; Krauss JK
    J Neurosurg Pediatr; 2012 Oct; 10(4):327-33. PubMed ID: 22880888
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.