  • 1. Detection of cutaneous oxygen saturation using a novel snapshot hyperspectral camera: a feasibility study.
    van Manen L; Birkhoff WAJ; Eggermont J; Hoveling RJM; Nicklin P; Burggraaf J; Wilson R; Mieog JSD; Robinson DJ; Vahrmeijer AL; Bradbury MS; Dijkstra J
    Quant Imaging Med Surg; 2021 Sep; 11(9):3966-3977. PubMed ID: 34476182
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of hyperspectral imaging to quantify perfusion changes during the modified Allen test.
    Linek M; Felicio-Briegel A; Freymüller C; Rühm A; Englhard AS; Sroka R; Volgger V
    Lasers Surg Med; 2022 Feb; 54(2):245-255. PubMed ID: 34541694
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is thenar tissue hemoglobin oxygen saturation in septic shock related to macrohemodynamic variables and outcome?
    Payen D; Luengo C; Heyer L; Resche-Rigon M; Kerever S; Damoisel C; Losser MR
    Crit Care; 2009; 13 Suppl 5(Suppl 5):S6. PubMed ID: 19951390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. HYPerspectral Enhanced Reality (HYPER): a physiology-based surgical guidance tool.
    Barberio M; Longo F; Fiorillo C; Seeliger B; Mascagni P; Agnus V; Lindner V; Geny B; Charles AL; Gockel I; Worreth M; Saadi A; Marescaux J; Diana M
    Surg Endosc; 2020 Apr; 34(4):1736-1744. PubMed ID: 31309313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of hand superficial oxygenation during ischemia/reperfusion in healthy subjects versus systemic sclerosis patients by 2D near infrared spectroscopic imaging.
    Jalil B; Hartwig V; Salvetti O; Potì L; Gargani L; Barskova T; Matucci Cerinic M; L'Abbate A
    Comput Methods Programs Biomed; 2018 Mar; 155():101-108. PubMed ID: 29512489
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diffuse reflectance spectroscopy for the measurement of tissue oxygen saturation.
    Sircan-Kucuksayan A; Uyuklu M; Canpolat M
    Physiol Meas; 2015 Dec; 36(12):2461-9. PubMed ID: 26536251
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bayer Filter Snapshot Hyperspectral Fundus Camera for Human Retinal Imaging.
    Kaluzny J; Li H; Liu W; Nesper P; Park J; Zhang HF; Fawzi AA
    Curr Eye Res; 2017 Apr; 42(4):629-635. PubMed ID: 27767345
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Hyperspectral Imaging for Follow-Up Assessment after Revascularization in Peripheral Artery Disease.
    Grambow E; Sandkühler NA; Groß J; Thiem DGE; Dau M; Leuchter M; Weinrich M
    J Clin Med; 2022 Jan; 11(3):. PubMed ID: 35160210
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a new instrument to measure oxygen saturation and total hemoglobin volume in local skin by near-infrared spectroscopy and its clinical application.
    Nagashima Y; Yada Y; Hattori M; Sakai A
    Int J Biometeorol; 2000 May; 44(1):11-9. PubMed ID: 10879423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult women.
    Jeger V; Jakob SM; Fontana S; Wolf M; Zimmermann H; Exadaktylos AK
    J Trauma Manag Outcomes; 2010 May; 4():5. PubMed ID: 20465822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of hyperspectral NIRS for quantitative measurements of tissue oxygen saturation by comparison to time-resolved NIRS.
    Kewin M; Rajaram A; Milej D; Abdalmalak A; Morrison L; Diop M; St Lawrence K
    Biomed Opt Express; 2019 Sep; 10(9):4789-4802. PubMed ID: 31565525
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers.
    Bezemer R; Lima A; Myers D; Klijn E; Heger M; Goedhart PT; Bakker J; Ince C
    Crit Care; 2009; 13 Suppl 5(Suppl 5):S4. PubMed ID: 19951388
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative measurement of bowel oxygen saturation using a multispectral imaging laparoscope.
    Clancy NT; Arya S; Stoyanov D; Singh M; Hanna GB; Elson DS
    Biomed Opt Express; 2015 Oct; 6(10):4179-90. PubMed ID: 26504664
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Video: Clinical evaluation of a laparoscopic hyperspectral imaging system.
    Pfahl A; Köhler H; Thomaßen MT; Maktabi M; Bloße AM; Mehdorn M; Lyros O; Moulla Y; Niebisch S; Jansen-Winkeln B; Chalopin C; Gockel I
    Surg Endosc; 2022 Oct; 36(10):7794-7799. PubMed ID: 35546207
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of bowel ischaemia using real-time multispectral Single Snapshot Imaging of Optical Properties (SSOP).
    Rodríguez-Luna MR; Okamoto N; Cinelli L; Baratelli L; Ségaud S; Rodríguez-Gómez A; Keller DS; Zonoobi E; Bannone E; Marescaux J; Diana M; Gioux S
    Surg Endosc; 2023 Mar; 37(3):2395-2403. PubMed ID: 36443562
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Human Stress and StO2: Database, Features, and Classification of Emotional and Physical Stress.
    Liu X; Shan Y; Peng M; Chen H; Chen T
    Entropy (Basel); 2020 Aug; 22(9):. PubMed ID: 33286731
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monitoring of Foot Oxygenation with Near-infrared Spectroscopy in Patients with Critical Limb Ischemia Undergoing Percutaneous Transluminal Angioplasty: A Pilot Study.
    Boezeman RP; Becx BP; van den Heuvel DA; Ünlü Ç; Vos JA; de Vries JP
    Eur J Vasc Endovasc Surg; 2016 Nov; 52(5):650-656. PubMed ID: 27614555
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status.
    McLay KM; Gilbertson JE; Pogliaghi S; Paterson DH; Murias JM
    Exp Physiol; 2016 Oct; 101(10):1309-1318. PubMed ID: 27430198
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bedside hyperspectral imaging indicates a microcirculatory sepsis pattern - an observational study.
    Dietrich M; Marx S; von der Forst M; Bruckner T; Schmitt FCF; Fiedler MO; Nickel F; Studier-Fischer A; Müller-Stich BP; Hackert T; Brenner T; Weigand MA; Uhle F; Schmidt K
    Microvasc Res; 2021 Jul; 136():104164. PubMed ID: 33831406
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hyperspectral imaging for perioperative monitoring of microcirculatory tissue oxygenation and tissue water content in pancreatic surgery - an observational clinical pilot study.
    Dietrich M; Marx S; von der Forst M; Bruckner T; Schmitt FCF; Fiedler MO; Nickel F; Studier-Fischer A; Müller-Stich BP; Hackert T; Brenner T; Weigand MA; Uhle F; Schmidt K
    Perioper Med (Lond); 2021 Dec; 10(1):42. PubMed ID: 34847953
    [TBL] [Abstract][Full Text] [Related]  