These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 34479186)

  • 1. Freehand screw insertion technique without image guidance for the cortical bone trajectory screw in posterior lumbar interbody fusion: what affects screw misplacement?
    Ishii M; Ohnishi A; Yamagishi A; Ohwada T
    J Neurosurg Spine; 2022 Jan; 36(1):1-7. PubMed ID: 34479186
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Posterior lumbar interbody fusion with cortical bone trajectory screw fixation versus posterior lumbar interbody fusion using traditional pedicle screw fixation for degenerative lumbar spondylolisthesis: a comparative study.
    Sakaura H; Miwa T; Yamashita T; Kuroda Y; Ohwada T
    J Neurosurg Spine; 2016 Nov; 25(5):591-595. PubMed ID: 27231813
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.
    Sakaura H; Miwa T; Yamashita T; Kuroda Y; Ohwada T
    J Neurosurg Spine; 2018 Jan; 28(1):57-62. PubMed ID: 29125430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early cephalad adjacent segment degeneration after posterior lumbar interbody fusion: a comparative study between cortical bone trajectory screw fixation and traditional trajectory screw fixation.
    Sakaura H; Ikegami D; Fujimori T; Sugiura T; Mukai Y; Hosono N; Fuji T
    J Neurosurg Spine; 2020 Feb; 32(2):155-159. PubMed ID: 31628292
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
    Malham GM; Parker RM
    J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Revisions for screw malposition and clinical outcomes after robot-guided lumbar fusion for spondylolisthesis.
    Schröder ML; Staartjes VE
    Neurosurg Focus; 2017 May; 42(5):E12. PubMed ID: 28463610
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a freehand technique for cortical bone trajectory screws in the lumbar spine.
    Tan Z; McLachlin S; Whyne C; Finkelstein J
    J Neurosurg Spine; 2019 Aug; 31(2):201-208. PubMed ID: 31003218
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates.
    Raley DA; Mobbs RJ
    Spine (Phila Pa 1976); 2012 May; 37(12):1092-100. PubMed ID: 22037528
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Feasibility of Assessing the Cortical Bone Trajectory Screw Placement Accuracy Using a Traditional Pedicle Screw Insertion Evaluation System.
    Ding H; Han B; Hai Y; Liu Y; Guan L; Pan A; Liu T
    Clin Spine Surg; 2021 Mar; 34(2):E112-E120. PubMed ID: 33633068
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical Comparison of Combined Cortical Bone Trajectory and Transarticular Surface Screw Versus Standard Pedicle Screw Insertion by Wiltse Approach for L5 Isthmic Spondylolisthesis.
    Terai H; Tamai K; Takahashi S; Umano M; Iwamae M; Toyoda H; Suzuki A; Hoshino M; Nakamura H
    Clin Spine Surg; 2021 Dec; 34(10):E580-E587. PubMed ID: 33769975
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Isthmus-guided Cortical Bone Trajectory Reduces Postoperative Increases in Serum Creatinine Phosphokinase Concentrations.
    Ohkawa T; Iwatsuki K; Ohnishi Y; Ninomiya K; Yoshimine T
    Orthop Surg; 2015 Aug; 7(3):232-8. PubMed ID: 26311097
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surgical outcomes after posterior lumbar interbody fusion using traditional trajectory screw fixation or cortical bone trajectory screw fixation: A comparative study between the polyetheretherketone cage and the same shape titanium-coated polyetheretherketone cage.
    Sakaura H; Ikegami D; Fujimori T; Sugiura T; Yamada S; Mukai Y
    Clin Neurol Neurosurg; 2021 Oct; 209():106945. PubMed ID: 34555798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiographic feasibility study of cortical bone trajectory and traditional pedicle screw dual trajectories.
    Mullin JP; Perlmutter B; Schmidt E; Benzel E; Steinmetz MP
    J Neurosurg Spine; 2016 Dec; 25(6):727-732. PubMed ID: 27391396
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine.
    Harris BM; Hilibrand AS; Savas PE; Pellegrino A; Vaccaro AR; Siegler S; Albert TJ
    Spine (Phila Pa 1976); 2004 Feb; 29(4):E65-70. PubMed ID: 15094547
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
    Ravindra VM; Kalra RR; Dailey AT
    Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Robot-assisted Percutaneous Transfacet Screw Fixation Supplementing Oblique Lateral Interbody Fusion Procedure: Accuracy and Safety Evaluation of This Novel Minimally Invasive Technique.
    Wu JY; Yuan Q; Liu YJ; Sun YQ; Zhang Y; Tian W
    Orthop Surg; 2019 Feb; 11(1):25-33. PubMed ID: 30776856
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive lumbar pedicle screw fixation using cortical bone trajectory - Screw accuracy, complications, and learning curve in 100 screw placements.
    Dayani F; Chen YR; Johnson E; Deb S; Wu Y; Pham L; Singh H
    J Clin Neurosci; 2019 Mar; 61():106-111. PubMed ID: 30420203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Increased Radiation but No Benefits in Pedicle Screw Accuracy With Navigation versus a Freehand Technique in Scoliosis Surgery.
    Urbanski W; Jurasz W; Wolanczyk M; Kulej M; Morasiewicz P; Dragan SL; Zaluski R; Miekisiak G; Dragan SF
    Clin Orthop Relat Res; 2018 May; 476(5):1020-1027. PubMed ID: 29432262
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lateral lumbar interbody fusion after reduction using the percutaneous pedicle screw system in the lateral position for Meyerding grade II spondylolisthesis: a preliminary report of a new lumbar reconstruction strategy.
    Takami M; Taiji R; Okada M; Minamide A; Hashizume H; Yamada H
    BMC Musculoskelet Disord; 2021 Jan; 22(1):17. PubMed ID: 33402131
    [TBL] [Abstract][Full Text] [Related]  

  • 20. May the midline lumbar interbody fusion (MIDLIF) prevent the early radiographic adjacent segment degeneration? A minimum 3-year follow-up comparative study of MIDLIF in L4/5 with cortical bone trajectory screw versus traditional pedicle screw fixation.
    Han B; Ding H; Hai Y; Liu Y; Guan L; Pan A; Zhang X; Yin P
    BMC Musculoskelet Disord; 2022 May; 23(1):480. PubMed ID: 35596180
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.