BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 34504136)

  • 1. Prolonged warm ischemia time leads to severe renal dysfunction of donation-after-cardiac death kidney grafts.
    Urbanellis P; Mazilescu L; Kollmann D; Linares-Cervantes I; Kaths JM; Ganesh S; Oquendo F; Sharma M; Goto T; Noguchi Y; John R; Konvalinka A; Mucsi I; Ghanekar A; Bagli D; Robinson LA; Selzner M
    Sci Rep; 2021 Sep; 11(1):17930. PubMed ID: 34504136
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low-dose In Situ Perfusion With Euro-Collins Solution Is Effective for the Procurement of Marginal Kidney Grafts From Donation After Circulatory Death Donors.
    Tojimbara T; Yashima J; Shirai H; Masaki N; Tonsho M; Teraoka S
    Transplant Proc; 2019 Oct; 51(8):2520-2522. PubMed ID: 31395361
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous Normothermic Ex Vivo Kidney Perfusion Improves Graft Function in Donation After Circulatory Death Pig Kidney Transplantation.
    Kaths JM; Echeverri J; Chun YM; Cen JY; Goldaracena N; Linares I; Dingwell LS; Yip PM; John R; Bagli D; Mucsi I; Ghanekar A; Grant DR; Robinson LA; Selzner M
    Transplantation; 2017 Apr; 101(4):754-763. PubMed ID: 27467537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Normothermic Ex Vivo Kidney Perfusion Improves Early DCD Graft Function Compared With Hypothermic Machine Perfusion and Static Cold Storage.
    Urbanellis P; Hamar M; Kaths JM; Kollmann D; Linares I; Mazilescu L; Ganesh S; Wiebe A; Yip PM; John R; Konvalinka A; Mucsi I; Ghanekar A; Bagli DJ; Robinson LA; Selzner M
    Transplantation; 2020 May; 104(5):947-955. PubMed ID: 31815900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Negative impact of prolonged cold storage time before machine perfusion preservation in donation after circulatory death kidney transplantation.
    Paloyo S; Sageshima J; Gaynor JJ; Chen L; Ciancio G; Burke GW
    Transpl Int; 2016 Oct; 29(10):1117-25. PubMed ID: 27421771
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Eight-Hour Continuous Normothermic Ex Vivo Kidney Perfusion Is a Safe Preservation Technique for Kidney Transplantation: A New Opportunity for the Storage, Assessment, and Repair of Kidney Grafts.
    Kaths JM; Echeverri J; Goldaracena N; Louis KS; Chun YM; Linares I; Wiebe A; Foltys DB; Yip PM; John R; Mucsi I; Ghanekar A; Bagli DJ; Grant DR; Robinson LA; Selzner M
    Transplantation; 2016 Sep; 100(9):1862-70. PubMed ID: 27479157
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hypothermic Machine Perfusion Results in a Marginal Kidney Transplant Programme.
    Gómez-Dos Santos V; Ruiz Hernández M; Burgos-Revilla FJ
    Eur Urol Focus; 2018 Mar; 4(2):163-168. PubMed ID: 29929872
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Preliminary experience of sequential use of normothermic and hypothermic oxygenated perfusion for donation after circulatory death kidney with warm ischemia time over the conventional criteria - a retrospective and observational study.
    Ravaioli M; De Pace V; Comai G; Capelli I; Baraldi O; D'Errico A; Bertuzzo VR; Del Gaudio M; Zanfi C; D'Arcangelo GL; Cuna V; Siniscalchi A; Sangiorgi G; La Manna G
    Transpl Int; 2018 Nov; 31(11):1233-1244. PubMed ID: 29957863
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Regional perfusion by extracorporeal membrane oxygenation of abdominal organs from donors after circulatory death: a systematic review.
    Shapey IM; Muiesan P
    Liver Transpl; 2013 Dec; 19(12):1292-303. PubMed ID: 24136827
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extracorporeal support: improves donor renal graft function after cardiac death.
    Rojas-Pena A; Reoma JL; Krause E; Boothman EL; Padiyar NP; Cook KE; Bartlett RH; Punch JD
    Am J Transplant; 2010 Jun; 10(6):1365-74. PubMed ID: 20553447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Significant Dysfunction of Kidney Grafts Exposed to Prolonged Warm Ischemia Is Minimized Through Normothermic Ex Vivo Kidney Perfusion.
    Urbanellis P; Kollmann D; Linares I; Ganesh S; Oquendo F; Mazilescu L; Goto T; Noguchi Y; John R; Konvalinka A; Mucsi I; Ghanekar A; Bagli D; Selzner M; Robinson LA
    Transplant Direct; 2020 Aug; 6(8):e587. PubMed ID: 32766435
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Benefits of Hypothermic Machine Preservation and Short Cold Ischemia Times in Deceased Donor Kidneys.
    Kox J; Moers C; Monbaliu D; Strelniece A; Treckmann J; Jochmans I; Leuvenink H; Van Heurn E; Pirenne J; Paul A; Ploeg R
    Transplantation; 2018 Aug; 102(8):1344-1350. PubMed ID: 29570164
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of quality of kidneys from donation after circulatory death/expanded criteria donors by parameters of machine perfusion.
    Chen G; Wang C; Zhao Y; Qiu L; Yuan X; Qiu J; Wang C; He X; Chen L
    Nephrology (Carlton); 2018 Feb; 23(2):103-106. PubMed ID: 27888556
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Kidney transplantation from donation after cardiac death donors: lack of impact of delayed graft function on post-transplant outcomes.
    Singh RP; Farney AC; Rogers J; Zuckerman J; Reeves-Daniel A; Hartmann E; Iskandar S; Adams P; Stratta RJ
    Clin Transplant; 2011; 25(2):255-64. PubMed ID: 20331689
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Successful donation after cardiac death liver transplants with prolonged warm ischemia time using normothermic regional perfusion.
    De Carlis R; Di Sandro S; Lauterio A; Ferla F; Dell'Acqua A; Zanierato M; De Carlis L
    Liver Transpl; 2017 Feb; 23(2):166-173. PubMed ID: 27783454
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The relative effects of warm and cold ischemic injury in an experimental model of nonheartbeating donor kidneys.
    Hosgood SA; Bagul A; Yang B; Nicholson ML
    Transplantation; 2008 Jan; 85(1):88-92. PubMed ID: 18192917
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of Hypothermic Machine Perfusion on the Preservation of Kidneys Donated After Cardiac Death: A Single-Center, Randomized, Controlled Trial.
    Wang W; Xie D; Hu X; Yin H; Liu H; Zhang X
    Artif Organs; 2017 Aug; 41(8):753-758. PubMed ID: 28176336
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcome Improvement for Hypothermic Machine Perfusion Versus Cold Storage for Kidneys From Cardiac Death Donors.
    Zhong Z; Lan J; Ye S; Liu Z; Fan L; Zhang Y; Fu Z; Qiao B; Shiu-Chung Ko D; Wang Y; Ye Q
    Artif Organs; 2017 Jul; 41(7):647-653. PubMed ID: 28703374
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous Normothermic Ex Vivo Kidney Perfusion Is Superior to Brief Normothermic Perfusion Following Static Cold Storage in Donation After Circulatory Death Pig Kidney Transplantation.
    Kaths JM; Cen JY; Chun YM; Echeverri J; Linares I; Ganesh S; Yip P; John R; Bagli D; Mucsi I; Ghanekar A; Grant DR; Robinson LA; Selzner M
    Am J Transplant; 2017 Apr; 17(4):957-969. PubMed ID: 27647696
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of kidney donor profile index on delayed graft function and transplant outcomes: A single-center analysis.
    Zens TJ; Danobeitia JS; Leverson G; Chlebeck PJ; Zitur LJ; Redfield RR; D'Alessandro AM; Odorico S; Kaufman DB; Fernandez LA
    Clin Transplant; 2018 Mar; 32(3):e13190. PubMed ID: 29314286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.