These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 34510520)

  • 1. The clinical role of transesophageal echocardiography during transvenous lead extraction.
    Wang L; Hai T; Feng Y; Han Q; Li Y; Ju H; Jiang Y; Li X; Ze F; Liu G; Jiang L
    Echocardiography; 2021 Sep; 38(9):1552-1557. PubMed ID: 34510520
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical utility of routine use of continuous transesophageal echocardiography monitoring during transvenous lead extraction procedure.
    Regoli F; Caputo M; Conte G; Faletra FF; Moccetti T; Pasotti E; Cassina T; Casso G; Schlotterbeck H; Engeler A; Auricchio A
    Heart Rhythm; 2015 Feb; 12(2):313-20. PubMed ID: 25311409
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transesophageal Echocardiography As a Monitoring Tool During Transvenous Lead Extraction-Does It Improve Procedure Effectiveness?
    Nowosielecka D; Jacheć W; Polewczyk A; Tułecki Ł; Tomków K; Stefańczyk P; Tomaszewski A; Brzozowski W; Szcześniak-Stańczyk D; Kleinrok A; Kutarski A
    J Clin Med; 2020 May; 9(5):. PubMed ID: 32397115
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transesophageal echocardiography for the monitoring of transvenous lead extraction.
    Nowosielecka D; Polewczyk A; Jacheć W; Kleinrok A; Tułecki Ł; Kutarski A
    Kardiol Pol; 2020 Dec; 78(12):1206-1214. PubMed ID: 33078921
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new approach to the continuous monitoring of transvenous lead extraction using transesophageal echocardiography-Analysis of 936 procedures.
    Nowosielecka D; Polewczyk A; Jacheć W; Tułecki Ł; Tomków K; Stefańczyk P; Kleinrok A; Kutarski A
    Echocardiography; 2020 Apr; 37(4):601-611. PubMed ID: 32154950
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical utility of intraprocedural transesophageal echocardiography during transvenous lead extraction.
    Endo Y; O'Mara JE; Weiner S; Han J; Goldberger MH; Gordon GM; Nanna M; Ferrick KJ; Gross JN
    J Am Soc Echocardiogr; 2008 Jul; 21(7):861-7. PubMed ID: 18313266
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of transesophageal echocardiography in predicting technical problems and complications of transvenous lead extractions procedures.
    Nowosielecka D; Jacheć W; Polewczyk A; Tułecki Ł; Kleinrok A; Kutarski A
    Clin Cardiol; 2021 Sep; 44(9):1233-1242. PubMed ID: 34302377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of the impact of organisational model of transvenous lead extraction on the effectiveness and safety of procedure: an observational study.
    Tułecki Ł; Jacheć W; Polewczyk A; Czajkowski M; Targońska S; Tomków K; Karpeta K; Nowosielecka D; Kutarski A
    BMJ Open; 2022 Dec; 12(12):e062952. PubMed ID: 36581437
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Presence of 'ghosts' and mortality after transvenous lead extraction.
    Narducci ML; Di Monaco A; Pelargonio G; Leoncini E; Boccia S; Mollo R; Perna F; Bencardino G; Pennestrì F; Scoppettuolo G; Rebuzzi AG; Santangeli P; Di Biase L; Natale A; Crea F
    Europace; 2017 Mar; 19(3):432-440. PubMed ID: 27025772
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New-onset pericardial effusion during transvenous lead extraction: incidence, causative mechanisms, and associated factors.
    Regoli F; D'Ambrosio G; Caputo ML; Svab S; Conte G; Moccetti T; Klersy C; Cassina T; Demertzis S; Auricchio A
    J Interv Card Electrophysiol; 2018 Apr; 51(3):253-261. PubMed ID: 29476380
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transvenous Lead Extraction without Procedure-Related Deaths in 1000 Consecutive Patients: A Single-Center Experience.
    Stefańczyk P; Nowosielecka D; Tułecki Ł; Tomków K; Polewczyk A; Jacheć W; Kleinrok A; Borzęcki W; Kutarski A
    Vasc Health Risk Manag; 2021; 17():445-459. PubMed ID: 34385818
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of Transesophageal Echocardiography to Improve the Safety of Transvenous Lead Extraction.
    Oestreich BA; Ahlgren B; Seres T; Zipse MM; Tompkins C; Varosy PD; Aleong RG
    JACC Clin Electrophysiol; 2015 Oct; 1(5):442-448. PubMed ID: 29759473
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transvenous lead extraction in patients with prior extraction procedures: Procedural profiles and outcomes.
    Hutt E; Diab M; Wazni OM; Kaur S; Tarakji KG; Saliba WI; Kanj M; Cantillon D; Rickard J; Varma N; Callahan T; Martin DO; Niebauer M; Dresing T; Chung M; Wilkoff BL; Hussein AA
    Heart Rhythm; 2020 Nov; 17(11):1904-1908. PubMed ID: 32512177
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rescue transoesophageal echocardiography for refractory haemodynamic instability during transvenous lead extraction.
    Hilberath JN; Burrage PS; Shernan SK; Varelmann DJ; Wilusz K; Fox JA; Eltzschig HK; Epstein LM; Nowak-Machen M
    Eur Heart J Cardiovasc Imaging; 2014 Aug; 15(8):926-32. PubMed ID: 24686256
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk Factors and Long-Term Survival of Octogenarians and Nonagenarians Undergoing Transvenous Lead Extraction Procedures.
    Jacheć W; Polewczyk A; Segreti L; Bongiorni MG; Kutarski A
    Gerontology; 2021; 67(1):36-48. PubMed ID: 33242867
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes.
    Bongiorni MG; Kennergren C; Butter C; Deharo JC; Kutarski A; Rinaldi CA; Romano SL; Maggioni AP; Andarala M; Auricchio A; Kuck KH; Blomström-Lundqvist C;
    Eur Heart J; 2017 Oct; 38(40):2995-3005. PubMed ID: 28369414
    [TBL] [Abstract][Full Text] [Related]  

  • 17. To grade or not to grade safety requirements for transvenous lead extraction: Experience with 2216 procedures.
    Kosior J; Jacheć W; Polewczyk A; Karpeta K; Cholewiński P; Czajkowski M; Kutarski A
    Kardiol Pol; 2023; 81(3):242-251. PubMed ID: 36446069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Utility of intracardiac echocardiography during transvenous lead extraction.
    Sadek MM; Cooper JM; Frankel DS; Santangeli P; Epstein AE; Marchlinski FE; Schaller RD
    Heart Rhythm; 2017 Dec; 14(12):1779-1785. PubMed ID: 28843419
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy and safety of transvenous lead extraction in 108 consecutive patients: a single-centre experience.
    Monsefi N; Waraich HS; Vamos M; Erath J; Sirat S; Moritz A; Hohnloser SH
    Interact Cardiovasc Thorac Surg; 2019 May; 28(5):704-708. PubMed ID: 30597017
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.