These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 34519358)

  • 1. Implementation and design of customized ex vivo machine perfusion. Analysis of its first results.
    Riveros S; Marino C; Ochoa G; Morales E; Soto D; Alegría L; Zenteno MJ; Brañes A; Achurra P; Rebolledo RA
    Artif Organs; 2022 Feb; 46(2):210-218. PubMed ID: 34519358
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Customized normothermic machine perfusion decreases ischemia-reperfusion injury compared with static cold storage in a porcine model of liver transplantation.
    Riveros S; Marino C; Ochoa G; Soto D; Alegría L; Zenteno MJ; San Martín S; Brañes A; Achurra P; Rebolledo R
    Artif Organs; 2023 Jan; 47(1):148-159. PubMed ID: 36007920
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ex Situ Machine Perfusion of Human Donor Livers via the Surgically Reopened Umbilical Vein: A Proof of Concept.
    van Leeuwen OB; Fujiyoshi M; Ubbink R; Werner MJM; Brüggenwirth IMA; Porte RJ; de Meijer VE
    Transplantation; 2019 Oct; 103(10):2130-2135. PubMed ID: 30801511
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Functional recovery of donation after cardiac death liver graft by continuous machine perfusion preservation in pigs.
    Shigeta T; Matsuno N; Obara H; Mizunuma H; Kanazawa H; Tanaka H; Fukuda A; Sakamoto S; Kasahara M; Uemoto S; Enosawa S
    Transplant Proc; 2012 May; 44(4):946-7. PubMed ID: 22564592
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transplantation of high-risk donor livers after resuscitation and viability assessment using a combined protocol of oxygenated hypothermic, rewarming and normothermic machine perfusion: study protocol for a prospective, single-arm study (DHOPE-COR-NMP trial).
    de Vries Y; Berendsen TA; Fujiyoshi M; van den Berg AP; Blokzijl H; de Boer MT; van der Heide F; de Kleine RHJ; van Leeuwen OB; Matton APM; Werner MJM; Lisman T; de Meijer VE; Porte R
    BMJ Open; 2019 Aug; 9(8):e028596. PubMed ID: 31420387
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodynamic, biochemical, and morphological characteristics during preservation of normal porcine livers by hypothermic machine perfusion.
    Monbaliu D; Vekemans K; De Vos R; Brassil J; Heedfeld V; Qiang L; D'hollander M; Roskams T; Pirenne J
    Transplant Proc; 2007 Oct; 39(8):2652-8. PubMed ID: 17954200
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The 24-hour normothermic machine perfusion of discarded human liver grafts.
    Vogel T; Brockmann JG; Quaglia A; Morovat A; Jassem W; Heaton ND; Coussios CC; Friend PJ
    Liver Transpl; 2017 Feb; 23(2):207-220. PubMed ID: 27809409
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Suitability of livers for transplantation when treated by normothermic machine perfusion.
    Allard MA; Castro-Benitez C; Imai K; Selten J; Lopez A; Sebagh M; Lemoine A; Sa Cunha A; Cherqui D; Castaing D; Vibert E; Adam R
    Clin Transplant; 2018 Jun; 32(6):e13256. PubMed ID: 29637631
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transplantation of High-risk Donor Livers After Ex Situ Resuscitation and Assessment Using Combined Hypo- and Normothermic Machine Perfusion: A Prospective Clinical Trial.
    van Leeuwen OB; de Vries Y; Fujiyoshi M; Nijsten MWN; Ubbink R; Pelgrim GJ; Werner MJM; Reyntjens KMEM; van den Berg AP; de Boer MT; de Kleine RHJ; Lisman T; de Meijer VE; Porte RJ
    Ann Surg; 2019 Nov; 270(5):906-914. PubMed ID: 31633615
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rescue of Discarded Grafts for Liver Transplantation by Ex Vivo Subnormothermic and Normothermic Oxygenated Machine Perfusion: First Experience in Spain.
    Ciria R; Ayllon-Teran MD; González-Rubio S; Gómez-Luque I; Ferrín G; Moreno A; Sánchez-Frías M; Alconchel F; Herrera C; Martín V; Sánchez-Hidalgo JM; Arjona-Sánchez Á; Okuda Y; Cabrera I; Benavente B; Rodriguez MJ; Jurado-Martínez I; Dueñas-Jurado JM; Robles-Arista JC; Rodriguez-Perálvarez M; de La Mata García M; López-Cillero P; Briceño J
    Transplant Proc; 2019; 51(1):20-24. PubMed ID: 30655130
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improvement of Normothermic Ex Vivo Machine Perfusion of Rat Liver Grafts by Dialysis and Kupffer Cell Inhibition With Glycine.
    Gassner JMGV; Nösser M; Moosburner S; Horner R; Tang P; Wegener L; Wyrwal D; Claussen F; Arsenic R; Pratschke J; Sauer IM; Raschzok N
    Liver Transpl; 2019 Feb; 25(2):275-287. PubMed ID: 30341973
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ex vivo normothermic machine perfusion is safe, simple, and reliable: results from a large animal model.
    Nassar A; Liu Q; Farias K; D'Amico G; Tom C; Grady P; Bennett A; Diago Uso T; Eghtesad B; Kelly D; Fung J; Abu-Elmagd K; Miller C; Quintini C
    Surg Innov; 2015 Feb; 22(1):61-9. PubMed ID: 24694840
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evolution Under Normothermic Machine Perfusion of Type 2 Donation After Cardiac Death Livers Discarded as Nontransplantable.
    Pavel MC; Reyner E; Molina V; Garcia R; Ruiz A; Roque R; Diaz A; Fuster J; Garcia-Valdecasas JC
    J Surg Res; 2019 Mar; 235():383-394. PubMed ID: 30691820
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transplantation of declined livers after normothermic perfusion.
    Quintini C; Del Prete L; Simioni A; Del Angel L; Diago Uso T; D'Amico G; Hashimoto K; Aucejo F; Fujiki M; Eghtesad B; Sasaki K; Kwon CHD; Cywinski J; Bennett A; Bilancini M; Miller C; Liu Q
    Surgery; 2022 Mar; 171(3):747-756. PubMed ID: 35065791
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Normothermic machine perfusion of donor livers without the need for human blood products.
    Matton APM; Burlage LC; van Rijn R; de Vries Y; Karangwa SA; Nijsten MW; Gouw ASH; Wiersema-Buist J; Adelmeijer J; Westerkamp AC; Lisman T; Porte RJ
    Liver Transpl; 2018 Apr; 24(4):528-538. PubMed ID: 29281862
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ex vivo normothermic machine perfusion and viability testing of discarded human donor livers.
    op den Dries S; Karimian N; Sutton ME; Westerkamp AC; Nijsten MW; Gouw AS; Wiersema-Buist J; Lisman T; Leuvenink HG; Porte RJ
    Am J Transplant; 2013 May; 13(5):1327-35. PubMed ID: 23463950
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sanguineous normothermic machine perfusion improves hemodynamics and biliary epithelial regeneration in donation after cardiac death porcine livers.
    Liu Q; Nassar A; Farias K; Buccini L; Baldwin W; Mangino M; Bennett A; O'Rourke C; Okamoto T; Uso TD; Fung J; Abu-Elmagd K; Miller C; Quintini C
    Liver Transpl; 2014 Aug; 20(8):987-99. PubMed ID: 24805852
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Advantages of normothermic perfusion over cold storage in liver preservation.
    Imber CJ; St Peter SD; Lopez de Cenarruzabeitia I; Pigott D; James T; Taylor R; McGuire J; Hughes D; Butler A; Rees M; Friend PJ
    Transplantation; 2002 Mar; 73(5):701-9. PubMed ID: 11907414
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ex Situ Normothermic Machine Perfusion of Donor Livers.
    Karimian N; Matton AP; Westerkamp AC; Burlage LC; Op den Dries S; Leuvenink HG; Lisman T; Uygun K; Markmann JF; Porte RJ
    J Vis Exp; 2015 May; (99):e52688. PubMed ID: 26067131
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Avoiding initial hypothermia does not improve liver graft quality in a porcine donation after circulatory death (DCD) model of normothermic perfusion.
    Nostedt JJ; Churchill T; Ghosh S; Thiesen A; Hopkins J; Lees MC; Adam B; Freed DH; Shapiro AMJ; Bigam DL
    PLoS One; 2019; 14(8):e0220786. PubMed ID: 31386697
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.