BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 34520014)

  • 1. On-Chip Platelet Activation Assessment: Microfluidic Emulation of Shear Stress Profiles Induced by Mechanical Circulatory Support Devices.
    Mencarini T; Bozzi S; Redaelli A
    Methods Mol Biol; 2022; 2373():201-212. PubMed ID: 34520014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microfluidic emulation of mechanical circulatory support device shear-mediated platelet activation.
    Dimasi A; Rasponi M; Sheriff J; Chiu WC; Bluestein D; Tran PL; Slepian MJ; Redaelli A
    Biomed Microdevices; 2015 Dec; 17(6):117. PubMed ID: 26578003
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microfluidic approaches for the assessment of blood cell trauma: a focus on thrombotic risk in mechanical circulatory support devices.
    Consolo F; Dimasi A; Rasponi M; Valerio L; Pappalardo F; Bluestein D; Slepian MJ; Fiore GB; Redaelli A
    Int J Artif Organs; 2016 Jun; 39(4):184-93. PubMed ID: 27034318
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.
    Li M; Walk R; Roka-Moiia Y; Sheriff J; Bluestein D; Barth EJ; Slepian MJ
    Artif Organs; 2020 Jun; 44(6):E226-E237. PubMed ID: 31876310
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aspirin has limited ability to modulate shear-mediated platelet activation associated with elevated shear stress of ventricular assist devices.
    Valerio L; Tran PL; Sheriff J; Brengle W; Ghosh R; Chiu WC; Redaelli A; Fiore GB; Pappalardo F; Bluestein D; Slepian MJ
    Thromb Res; 2016 Apr; 140():110-117. PubMed ID: 26938158
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Device thrombogenicity emulation: a novel method for optimizing mechanical circulatory support device thromboresistance.
    Girdhar G; Xenos M; Alemu Y; Chiu WC; Lynch BE; Jesty J; Einav S; Slepian MJ; Bluestein D
    PLoS One; 2012; 7(3):e32463. PubMed ID: 22396768
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Platelet adhesion emulation: A novel method for estimating the device thrombosis potential of a ventricular assist device.
    Liu GM; Chen HB; Hou JF; Zhang Y; Hu SS
    Int J Artif Organs; 2020 Apr; 43(4):252-257. PubMed ID: 31709882
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD.
    Chiu WC; Girdhar G; Xenos M; Alemu Y; Soares JS; Einav S; Slepian M; Bluestein D
    J Biomech Eng; 2014 Feb; 136(2):021014. PubMed ID: 24337144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prothrombotic activity of cytokine-activated endothelial cells and shear-activated platelets in the setting of ventricular assist device support.
    Apostoli A; Bianchi V; Bono N; Dimasi A; Ammann KR; Moiia YR; Montisci A; Sheriff J; Bluestein D; Fiore GB; Pappalardo F; Candiani G; Redaelli A; Slepian MJ; Consolo F
    J Heart Lung Transplant; 2019 Jun; 38(6):658-667. PubMed ID: 30846234
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Device-induced platelet dysfunction in mechanically assisted circulation increases the risks of thrombosis and bleeding.
    Chen Z; Zhang J; Kareem K; Tran D; Conway RG; Arias K; Griffith BP; Wu ZJ
    Artif Organs; 2019 Aug; 43(8):745-755. PubMed ID: 30805954
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Device Thrombogenicity Emulation: An In Silico Predictor of In Vitro and In Vivo Ventricular Assist Device Thrombogenicity.
    Chiu WC; Tran PL; Khalpey Z; Lee E; Woo YR; Slepian MJ; Bluestein D
    Sci Rep; 2019 Feb; 9(1):2946. PubMed ID: 30814674
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shear-Mediated Platelet Activation Enhances Thrombotic Complications in Patients With LVADs and Is Reversed After Heart Transplantation.
    Consolo F; Sferrazza G; Motolone G; Pieri M; De Bonis M; Zangrillo A; Redaelli A; Slepian MJ; Pappalardo F
    ASAIO J; 2019; 65(4):e33-e35. PubMed ID: 29952802
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.
    Bluestein D; Girdhar G; Einav S; Slepian MJ
    J Biomech; 2013 Jan; 46(2):338-44. PubMed ID: 23219278
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microfludic platforms for the evaluation of anti-platelet agent efficacy under hyper-shear conditions associated with ventricular assist devices.
    Dimasi A; Rasponi M; Consolo F; Fiore GB; Bluestein D; Slepian MJ; Redaelli A
    Med Eng Phys; 2017 Oct; 48():31-38. PubMed ID: 28869117
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of shear rate and surface chemistry on thrombus formation in micro-crevice.
    Zhussupbekov M; Wu WT; Jamiolkowski MA; Massoudi M; Antaki JF
    J Biomech; 2021 May; 121():110397. PubMed ID: 33845357
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Shear-mediated platelet activation in patients implanted with continuous flow LVADs: A preliminary study utilizing the platelet activity state (PAS) assay.
    Valerio L; Consolo F; Bluestein D; Tran P; Slepian M; Redaelli A; Pappalardo F
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():1255-8. PubMed ID: 26736495
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Repetitive Hypershear Activates and Sensitizes Platelets in a Dose-Dependent Manner.
    Sheriff J; Tran PL; Hutchinson M; DeCook T; Slepian MJ; Bluestein D; Jesty J
    Artif Organs; 2016 Jun; 40(6):586-95. PubMed ID: 26527361
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation.
    Chen Z; Zhang J; Li T; Tran D; Griffith BP; Wu ZJ
    Artif Organs; 2020 May; 44(5):E201-E213. PubMed ID: 31849074
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The platelet hammer: In vitro platelet activation under repetitive hypershear.
    Sheriff J; Tran PL; Hutchinson M; DeCook T; Slepian MJ; Bluestein D; Jesty J
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():262-5. PubMed ID: 26736250
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the Use of the Platelet Activity State Assay for the In Vitro Quantification of Platelet Activation in Blood Recirculating Devices for Extracorporeal Circulation.
    Consolo F; Valerio L; Brizzola S; Rota P; Marazzato G; Vincoli V; Reggiani S; Redaelli A; Fiore G
    Artif Organs; 2016 Oct; 40(10):971-980. PubMed ID: 26748664
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.