BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 34520081)

  • 1. Technical Note: Effects of rotating gantry on magnetic field and eddy currents in 0.35 T MRI-guided radiotherapy (MR-IGRT) system.
    Michael Gach H; Curcuru AN; Kim T; Yang D
    Med Phys; 2021 Nov; 48(11):7228-7235. PubMed ID: 34520081
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of B
    Curcuru AN; Lewis BC; Kim T; Yang D; Michael Gach H
    Med Phys; 2021 Jun; 48(6):2929-2938. PubMed ID: 33720421
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time B
    Curcuru AN; Kim T; Yang D; Gach HM
    Med Phys; 2022 Oct; 49(10):6451-6460. PubMed ID: 35906957
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of real-time cine MR imaging distortion on 0.35 T MRgRT with concentric cine imaging QA phantom.
    Marasini S; Cole M; Curcuru A; Dyke LM; Gach HM; Flores R; Kim T
    Phys Med Biol; 2024 Mar; 69(6):. PubMed ID: 38408387
    [No Abstract]   [Full Text] [Related]  

  • 5. MRI quality control for low-field MR-IGRT systems: Lessons learned.
    Michael Gach H; Curcuru AN; Wittland EJ; Maraghechi B; Cai B; Mutic S; Green OL
    J Appl Clin Med Phys; 2019 Oct; 20(10):53-66. PubMed ID: 31541542
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MRI B
    Jackson S; Glitzner M; Tijssen RHN; Raaymakers BW
    Phys Med Biol; 2019 Jun; 64(12):12NT01. PubMed ID: 31108467
    [TBL] [Abstract][Full Text] [Related]  

  • 7. B
    Gach HM; Curcuru AN; Mutic S; Kim T
    Med Phys; 2020 Sep; 47(9):4101-4114. PubMed ID: 32472707
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of an MRI linac magnetic isocenter walkout with gantry rotation in the presence of angle-specific corrections.
    Lotey R; Latifi K; Moros EG; Feygelman V
    Phys Med Biol; 2023 Apr; 68(8):. PubMed ID: 36958055
    [No Abstract]   [Full Text] [Related]  

  • 9. From static to dynamic 1.5T MRI-linac prototype: impact of gantry position related magnetic field variation on image fidelity.
    Crijns S; Raaymakers B
    Phys Med Biol; 2014 Jul; 59(13):3241-7. PubMed ID: 24874027
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterizing MR Imaging isocenter variation in MRgRT.
    Kim T; Gu B; Maraghechi B; Green O; Lewis B; Mutic S; Gach HM
    Biomed Phys Eng Express; 2020 Mar; 6(3):035009. PubMed ID: 33438654
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of cine imaging during multileaf collimator and gantry motion for real-time magnetic resonance guided radiation therapy.
    Kielbasa JE; Meeks SL; Kelly P; Willoughby TR; Zeidan O; Shah AP
    J Appl Clin Med Phys; 2020 Dec; 21(12):178-187. PubMed ID: 33226709
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Correction of B
    Robison RK; Li Z; Wang D; Ooi MB; Pipe JG
    Magn Reson Med; 2019 Apr; 81(4):2501-2513. PubMed ID: 30444004
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comprehensive geometric quality assurance framework for preclinical microirradiators.
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2019 Apr; 46(4):1840-1851. PubMed ID: 30656713
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization and correction of center-frequency effects in X-nuclear eddy current compensations on a clinical MR system.
    McLean MA; Hinks RS; Kaggie JD; Woitek R; Riemer F; Graves MJ; McIntyre DJO; Gallagher FA; Schulte RF
    Magn Reson Med; 2021 May; 85(5):2370-2376. PubMed ID: 33274790
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two-dimensional EPID dosimetry for an MR-linac: Proof of concept.
    Torres-Xirau I; Olaciregui-Ruiz I; van der Heide UA; Mans A
    Med Phys; 2019 Sep; 46(9):4193-4203. PubMed ID: 31199521
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The adaptation and investigation of cone-beam CT reconstruction algorithms for horizontal rotation fixed-gantry scans of rabbits.
    Gardner M; Dillon O; Shieh CC; O'Brien R; Debrot E; Barber J; Ahern V; Bennett P; Heng SM; Corde S; Jackson M; Keall P
    Phys Med Biol; 2021 May; 66(10):. PubMed ID: 33878747
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Imperfect magnetic field gradients in radial k-space encoding-Quantification, correction, and parameter dependency.
    Moussavi A; Boretius S
    Magn Reson Med; 2019 Feb; 81(2):962-975. PubMed ID: 30260028
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrafast single breath-hold cone-beam CT lung cancer imaging with faster linac gantry rotation.
    Arns A; Wertz H; Boda-Heggemann J; Schneider F; Blessing M; Abo-Madyan Y; Steil V; Wenz F; Fleckenstein J
    Radiother Oncol; 2019 Jun; 135():78-85. PubMed ID: 31015174
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reversed half-echo stack-of-stars TrueFISP (TrueSTAR).
    Bauman G; Bieri O
    Magn Reson Med; 2016 Aug; 76(2):583-90. PubMed ID: 26332134
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical note: Minimizing CIED artifacts on a 0.35 T MRI-Linac using deep learning.
    Curcuru AN; Yang D; An H; Cuculich PS; Robinson CG; Gach HM
    J Appl Clin Med Phys; 2024 Mar; 25(3):e14304. PubMed ID: 38368615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.