These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 34524025)

  • 1. Quantitative physical examination indicators to detect patients with stenosis at a high risk of thrombosis at hemodialysis vascular access sites: A retrospective case-control study.
    Chen MC; Weng MJ; Chao LH; Wu MY; Liu YC; Chi WC
    J Vasc Access; 2023 Jul; 24(4):639-645. PubMed ID: 34524025
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification of the severity of outflow stenosis of hemodialysis fistulas with a pulse- and thrill-based scoring system.
    Chen MC; Weng MJ; Chang BC; Lai HC; Wu MY; Fu CY; Liu YC; Chi WC
    BMC Nephrol; 2020 Jul; 21(1):304. PubMed ID: 32711458
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measuring the palpable pulsatility length as a physical examination test in defining the severity of inflow stenosis for hemodialysis fistulas.
    Chen MC; Weng MJ; Wu MY; Liu YC; Chi WC
    BMC Nephrol; 2019 Sep; 20(1):356. PubMed ID: 31519166
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Physical examination of dysfunctional arteriovenous fistulae by non-interventionalists: a skill worth teaching.
    Coentrão L; Faria B; Pestana M
    Nephrol Dial Transplant; 2012 May; 27(5):1993-6. PubMed ID: 21940486
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparing non-invasive diagnostic methods for arteriovenous fistula stenosis: a prospective study.
    Raksasuk S; Naweera W; Rojwatcharapibarn S; Srithongkul T
    J Ultrasound; 2023 Sep; 26(3):687-693. PubMed ID: 36319839
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula.
    Campos RP; Chula DC; Perreto S; Riella MC; do Nascimento MM
    Semin Dial; 2008; 21(3):269-73. PubMed ID: 18248519
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring and Surveillance of Hemodialysis Vascular Access Using StenTec and Physical Exam.
    Dhamija R; Nash SK; Nguyen SV; Slack K; Tadeo J
    Semin Dial; 2015; 28(3):299-304. PubMed ID: 25346002
    [TBL] [Abstract][Full Text] [Related]  

  • 8. ASDIN white paper: Management of cephalic arch stenosis endorsed by the American Society of Diagnostic and Interventional Nephrology.
    Beathard GA; Jennings WC; Wasse H; Shenoy S; Falk A; Urbanes A; Ross J; Nassar G; Hentschel DM; Sachdeva B; Chan MR; Salman L; Asif A
    J Vasc Access; 2023 May; 24(3):358-369. PubMed ID: 34392712
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemodialysis arteriovenous access: detection of stenosis and response to treatment by vascular access blood flow.
    Schwab SJ; Oliver MJ; Suhocki P; McCann R
    Kidney Int; 2001 Jan; 59(1):358-62. PubMed ID: 11135091
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Postintervention Patency: A Comparison of Stenting versus Patch Angioplasty for Dysfunctional Hemodialysis Access Sites.
    Trinh KN; Wilson SE; Gordon IL; Williams RA
    Ann Vasc Surg; 2016 May; 33():120-5. PubMed ID: 26965804
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Value of Doppler evaluation of physically abnormal fistula: hemodynamic guidelines and access outcomes.
    Cho S; Lee YJ; Kim SR
    Korean J Intern Med; 2019 Jan; 34(1):137-145. PubMed ID: 28415162
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In search of an optimal bedside screening program for arteriovenous fistula stenosis.
    Tessitore N; Bedogna V; Melilli E; Millardi D; Mansueto G; Lipari G; Mantovani W; Baggio E; Poli A; Lupo A
    Clin J Am Soc Nephrol; 2011 Apr; 6(4):819-26. PubMed ID: 21454718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Best threshold for diagnosis of stenosis or thrombosis within six months of access flow measurement in arteriovenous fistulae.
    Tonelli M; Jhangri GS; Hirsch DJ; Marryatt J; Mossop P; Wile C; Jindal KK
    J Am Soc Nephrol; 2003 Dec; 14(12):3264-9. PubMed ID: 14638925
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of physical examination in the detection of arteriovenous fistula stenosis.
    Asif A; Leon C; Orozco-Vargas LC; Krishnamurthy G; Choi KL; Mercado C; Merrill D; Thomas I; Salman L; Artikov S; Bourgoignie JJ
    Clin J Am Soc Nephrol; 2007 Nov; 2(6):1191-4. PubMed ID: 17928468
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis.
    Tessitore N; Bedogna V; Gammaro L; Lipari G; Poli A; Baggio E; Firpo M; Morana G; Mansueto G; Maschio G
    Am J Kidney Dis; 2003 Aug; 42(2):331-41. PubMed ID: 12900816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemodynamically significant arterial inflow stenosis in dysfunctional hemodialysis arteriovenous fistulae and grafts.
    Wu S; Joe JM; Covarrubias DA; Kalva SP
    J Vasc Access; 2012; 13(4):452-8. PubMed ID: 22729525
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Subjective Global Assessment-Dialysis Malnutrition Score and arteriovenous fistula outcome: A comparison with Charlson Comorbidity Index.
    Spatola L; Finazzi S; Calvetta A; Angelini C; Badalamenti S
    J Vasc Access; 2019 Jan; 20(1):70-78. PubMed ID: 29874975
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inflow stenosis in arteriovenous fistulas and grafts: a multicenter, prospective study.
    Asif A; Gadalean FN; Merrill D; Cherla G; Cipleu CD; Epstein DL; Roth D
    Kidney Int; 2005 May; 67(5):1986-92. PubMed ID: 15840048
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retrograde catheterization of haemodialysis fistulae and grafts: angiographic depiction of the entire vascular access tree and stenosis treatment.
    Duijm LE; Overbosch EH; Liem YS; Planken RN; Tordoir JH; Cuypers PW; Douwes-Draaijer P; de Haan MW
    Nephrol Dial Transplant; 2009 Feb; 24(2):539-47. PubMed ID: 18802208
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Value of clinical screening for detection of asymptomatic hemodialysis vascular access stenoses.
    Levy SS; Sherman RA; Nosher JL
    Angiology; 1992 May; 43(5):421-4. PubMed ID: 1567066
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.