These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 34528164)

  • 1. Optimization of 4D flow MRI velocity field in the aorta with divergence-free smoothing.
    Gao Q; Liu X; Wang H; Wu P; Jin M; Wei R; Wang W; Niu Z; Zhao S; Li F
    Med Biol Eng Comput; 2021 Nov; 59(11-12):2237-2252. PubMed ID: 34528164
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wall Shear Stress Estimation for 4D Flow MRI Using Navier-Stokes Equation Correction.
    Zhang J; Rothenberger SM; Brindise MC; Markl M; Rayz VL; Vlachos PP
    Ann Biomed Eng; 2022 Dec; 50(12):1810-1825. PubMed ID: 35943617
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The impact of 4D-Flow MRI spatial resolution on patient-specific CFD simulations of the thoracic aorta.
    Cherry M; Khatir Z; Khan A; Bissell M
    Sci Rep; 2022 Sep; 12(1):15128. PubMed ID: 36068322
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI.
    Ko S; Yang B; Cho JH; Lee J; Song S
    Med Image Anal; 2019 Apr; 53():95-103. PubMed ID: 30743192
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Toward an accurate estimation of wall shear stress from 4D flow magnetic resonance downstream of a severe stenosis.
    Corso P; Walheim J; Dillinger H; Giannakopoulos G; Gülan U; Frouzakis CE; Kozerke S; Holzner M
    Magn Reson Med; 2021 Sep; 86(3):1531-1543. PubMed ID: 33914962
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spatial resolution and velocity field improvement of 4D-flow MRI.
    Callaghan FM; Grieve SM
    Magn Reson Med; 2017 Nov; 78(5):1959-1968. PubMed ID: 27885707
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of numerical simulation methods in aortic arch using 4D Flow MRI.
    Miyazaki S; Itatani K; Furusawa T; Nishino T; Sugiyama M; Takehara Y; Yasukochi S
    Heart Vessels; 2017 Aug; 32(8):1032-1044. PubMed ID: 28444501
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimization of 4D Flow MRI Spatial and Temporal Resolution for Examining Complex Hemodynamics in the Carotid Artery Bifurcation.
    El Sayed R; Sharifi A; Park CC; Haussen DC; Allen JW; Oshinski JN
    Cardiovasc Eng Technol; 2023 Jun; 14(3):476-488. PubMed ID: 37156900
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of turbulent blood flow and wall shear stress in aortic coarctation using image-based simulations.
    Perinajová R; Juffermans JF; Mercado JL; Aben JP; Ledoux L; Westenberg JJM; Lamb HJ; Kenjereš S
    Biomed Eng Online; 2021 Aug; 20(1):84. PubMed ID: 34419047
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemodynamic Study of a Patient-Specific Intracranial Aneurysm: Comparative Assessment of Tomographic PIV, Stereoscopic PIV, In Vivo MRI and Computational Fluid Dynamics.
    Wu X; Gürzing S; Schinkel C; Toussaint M; Perinajová R; van Ooij P; Kenjereš S
    Cardiovasc Eng Technol; 2022 Jun; 13(3):428-442. PubMed ID: 34750782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A multi-modality approach for enhancing 4D flow magnetic resonance imaging via sparse representation.
    Zhang J; Brindise MC; Rothenberger SM; Markl M; Rayz VL; Vlachos PP
    J R Soc Interface; 2022 Jan; 19(186):20210751. PubMed ID: 35042385
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Towards quantitative evaluation of wall shear stress from 4D flow imaging.
    Levilly S; Castagna M; Idier J; Bonnefoy F; Le Touzé D; Moussaoui S; Paul-Gilloteaux P; Serfaty JM
    Magn Reson Imaging; 2020 Dec; 74():232-243. PubMed ID: 32889090
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta.
    van Ooij P; Powell AL; Potters WV; Carr JC; Markl M; Barker AJ
    J Magn Reson Imaging; 2016 Jan; 43(1):236-48. PubMed ID: 26140480
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparison of 4D flow MRI-derived wall shear stress with computational fluid dynamics methods for intracranial aneurysms and carotid bifurcations - A review.
    Szajer J; Ho-Shon K
    Magn Reson Imaging; 2018 May; 48():62-69. PubMed ID: 29223732
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comprehensive MRI-based computational model of blood flow in compliant aorta using radial basis function interpolation.
    Perinajová R; van de Ven T; Roelse E; Xu F; Juffermans J; Westenberg J; Lamb H; Kenjereš S
    Biomed Eng Online; 2024 Jul; 23(1):69. PubMed ID: 39039565
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow-based method demonstrates improved accuracy for calculating wall shear stress in arterial flows from 4D flow MRI data.
    Hurd ER; Iffrig E; Jiang D; Oshinski JN; Timmins LH
    J Biomech; 2023 Jan; 146():111413. PubMed ID: 36535100
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The impact of 4D flow displacement artifacts on wall shear stress estimation.
    Schmidt S; Flassbeck S; Schmelter S; Schmeyer E; Ladd ME; Schmitter S
    Magn Reson Med; 2021 Jun; 85(6):3154-3168. PubMed ID: 33421221
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wall shear stress estimation in the aorta: Impact of wall motion, spatiotemporal resolution, and phase noise.
    Zimmermann J; Demedts D; Mirzaee H; Ewert P; Stern H; Meierhofer C; Menze B; Hennemuth A
    J Magn Reson Imaging; 2018 Apr; ():. PubMed ID: 29607574
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Volumetric segmentation-free method for rapid visualization of vascular wall shear stress using 4D flow MRI.
    Masutani EM; Contijoch F; Kyubwa E; Cheng J; Alley MT; Vasanawala S; Hsiao A
    Magn Reson Med; 2018 Aug; 80(2):748-755. PubMed ID: 29516632
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bileaflet mechanical aortic valves do not alter ascending aortic wall shear stress.
    Farag ES; Schade EL; van Ooij P; Boekholdt SM; Planken RN; van Kimmenade R; Nederveen AJ; de Mol BAJM; Kluin J
    Int J Cardiovasc Imaging; 2019 Apr; 35(4):703-710. PubMed ID: 30741363
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.