604 related articles for article (PubMed ID: 34534059)
21. [Biomechanical parameters and clinical outcomes of the Oxford Phase III unicompartmental knee replacement].
Kubát P; Ptáček Z
Acta Chir Orthop Traumatol Cech; 2011; 78(4):367-72. PubMed ID: 21888850
[TBL] [Abstract][Full Text] [Related]
22. Comparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and Microplasty® instrumentation in unicompartmental knee arthroplasty.
Çabuk H; Turan K; Muratoğlu OG; Ergün T; Öztürk Ç; Ertürer RE
Jt Dis Relat Surg; 2022; 33(3):580-587. PubMed ID: 36345186
[TBL] [Abstract][Full Text] [Related]
23. Total Knee Arthroplasty in the Valgus Knee: Can New Operative Technologies Affect Surgical Technique and Outcomes?
Marchand RC; Scholl L; Bhowmik-Stoker M; Taylor KB; Marchand KB; Chen Z; Mont MA
Surg Technol Int; 2021 Jul; 39():389-393. PubMed ID: 34312827
[TBL] [Abstract][Full Text] [Related]
24. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT.
Slevin O; Hirschmann A; Schiapparelli FF; Amsler F; Huegli RW; Hirschmann MT
Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1602-1609. PubMed ID: 29026941
[TBL] [Abstract][Full Text] [Related]
25. Cemented all polyethylene tibial insert unicompartimental knee arthroplasty: a long term follow-up study.
Lustig S; Paillot JL; Servien E; Henry J; Ait Si Selmi T; Neyret P
Orthop Traumatol Surg Res; 2009 Feb; 95(1):12-21. PubMed ID: 19251232
[TBL] [Abstract][Full Text] [Related]
26. External rotation of the tibial component should be avoided in lateral unicompartmental knee arthroplasty.
Fujita M; Hiranaka T; Mai B; Kamenaga T; Tsubosaka M; Takayama K; Kuroda R; Matsumoto T
Knee; 2021 Jun; 30():70-77. PubMed ID: 33873088
[TBL] [Abstract][Full Text] [Related]
27. Bone morphotypes of the varus and valgus knee.
Thienpont E; Schwab PE; Cornu O; Bellemans J; Victor J
Arch Orthop Trauma Surg; 2017 Mar; 137(3):393-400. PubMed ID: 28110363
[TBL] [Abstract][Full Text] [Related]
28. Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes.
Nedopil AJ; Howell SM; Hull ML
Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3118-3127. PubMed ID: 31768572
[TBL] [Abstract][Full Text] [Related]
29. Total knee arthroplasty in femoral bowing: does patient specific instrumentation have something to add? A randomized controlled trial.
ALShammari SA; Choi KY; Koh IJ; Kim MS; In Y
BMC Musculoskelet Disord; 2021 Apr; 22(1):321. PubMed ID: 33794854
[TBL] [Abstract][Full Text] [Related]
30. High accuracy in knee alignment and implant placement in unicompartmental medial knee replacement when using patient-specific instrumentation.
Volpi P; Prospero E; Bait C; Cervellin M; Quaglia A; Redaelli A; Denti M
Knee Surg Sports Traumatol Arthrosc; 2015 May; 23(5):1292-1298. PubMed ID: 24306122
[TBL] [Abstract][Full Text] [Related]
31. Increases in tibial force imbalance but not changes in tibiofemoral laxities are caused by varus-valgus malalignment of the femoral component in kinematically aligned TKA.
Riley J; Roth JD; Howell SM; Hull ML
Knee Surg Sports Traumatol Arthrosc; 2018 Nov; 26(11):3238-3248. PubMed ID: 29380010
[TBL] [Abstract][Full Text] [Related]
32. New instrumentation system for cementless mobile-bearing unicompartmental knee arthroplasty improves surgical performance particularly for trainees.
Alvand A; Wilson HA; Sabah SA; Middleton R; Bottomley N; Jackson WFM; Price AJ
Knee; 2021 Aug; 31():46-53. PubMed ID: 34111801
[TBL] [Abstract][Full Text] [Related]
33. [Influence of rotatory malposition of femoral implant in failure of unicompartimental medial knee prosthesis].
Assor M; Aubaniac JM
Rev Chir Orthop Reparatrice Appar Mot; 2006 Sep; 92(5):473-84. PubMed ID: 17088741
[TBL] [Abstract][Full Text] [Related]
34. Dependence of knee range of motion on the alignment of femoral and tibial components after medial unicompartmental knee arthroplasty.
Hanada M; Hotta K; Matsuyama Y
Eur J Orthop Surg Traumatol; 2021 Feb; 31(2):291-298. PubMed ID: 32815031
[TBL] [Abstract][Full Text] [Related]
35. Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty?
Howell SM; Papadopoulos S; Kuznik K; Ghaly LR; Hull ML
Int Orthop; 2015 Nov; 39(11):2117-24. PubMed ID: 25823516
[TBL] [Abstract][Full Text] [Related]
36. Valgus Stress Radiograph Can Predict Alignment Change of Medial Mobile-Bearing Unicompartmental Knee Arthroplasty.
Jiao X; Li Z; Du M; An S; Huang J; Cao G
Orthop Surg; 2023 Jul; 15(7):1847-1853. PubMed ID: 37395116
[TBL] [Abstract][Full Text] [Related]
37. Varus placement of the tibial component reduces the potential risk of fracture with adequate bony coverage in the Oxford unicompartmental knee arthroplasty.
Kamenaga T; Hiranaka T; Suda Y; Fujishiro T; Okamoto K; Kuroda R; Matsumoto T
Sci Rep; 2024 Jan; 14(1):1274. PubMed ID: 38218913
[TBL] [Abstract][Full Text] [Related]
38. Alignment in Medial Fixed-Bearing Unicompartmental Knee Arthroplasty: The Limb Has a Leg Up on the Component.
Slaven SE; Cody JP; Sershon RA; Ho H; Hopper RH; Fricka KB
J Arthroplasty; 2021 Dec; 36(12):3883-3887. PubMed ID: 34489145
[TBL] [Abstract][Full Text] [Related]
39. [Individualized unicondylar knee replacement : Use of patient-specific implants and instruments].
Arnholdt J; Holzapfel BM; Sefrin L; Rudert M; Beckmann J; Steinert AF
Oper Orthop Traumatol; 2017 Feb; 29(1):31-39. PubMed ID: 28144717
[TBL] [Abstract][Full Text] [Related]
40. Component placement accuracy in two generations of handheld robotics-assisted knee arthroplasty.
Sicat CS; Chow JC; Kaper B; Mitra R; Xie J; Schwarzkopf R
Arch Orthop Trauma Surg; 2021 Dec; 141(12):2059-2067. PubMed ID: 34304279
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]