These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
301 related articles for article (PubMed ID: 34542168)
1. The effect of patient ethnicity on the accuracy of peripheral pulse oximetry in patients with COVID-19 pneumonitis: a single-centre, retrospective analysis. Wiles MD; El-Nayal A; Elton G; Malaj M; Winterbottom J; Gillies C; Moppett IK; Bauchmuller K Anaesthesia; 2022 Feb; 77(2):143-152. PubMed ID: 34542168 [TBL] [Abstract][Full Text] [Related]
2. Racial and Ethnic Discrepancy in Pulse Oximetry and Delayed Identification of Treatment Eligibility Among Patients With COVID-19. Fawzy A; Wu TD; Wang K; Robinson ML; Farha J; Bradke A; Golden SH; Xu Y; Garibaldi BT JAMA Intern Med; 2022 Jul; 182(7):730-738. PubMed ID: 35639368 [TBL] [Abstract][Full Text] [Related]
3. The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis. Shi C; Goodall M; Dumville J; Hill J; Norman G; Hamer O; Clegg A; Watkins CL; Georgiou G; Hodkinson A; Lightbody CE; Dark P; Cullum N BMC Med; 2022 Aug; 20(1):267. PubMed ID: 35971142 [TBL] [Abstract][Full Text] [Related]
4. Clinical Outcomes Associated With Overestimation of Oxygen Saturation by Pulse Oximetry in Patients Hospitalized With COVID-19. Fawzy A; Wu TD; Wang K; Sands KE; Fisher AM; Arnold Egloff SA; DellaVolpe JD; Iwashyna TJ; Xu Y; Garibaldi BT JAMA Netw Open; 2023 Aug; 6(8):e2330856. PubMed ID: 37615985 [TBL] [Abstract][Full Text] [Related]
5. Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation. Philip KEJ; Bennett B; Fuller S; Lonergan B; McFadyen C; Burns J; Tidswell R; Vlachou A BMJ Open Respir Res; 2020 Dec; 7(1):. PubMed ID: 33361436 [TBL] [Abstract][Full Text] [Related]
6. Effect of skin tone on the accuracy of the estimation of arterial oxygen saturation by pulse oximetry: a systematic review. Martin D; Johns C; Sorrell L; Healy E; Phull M; Olusanya S; Peters M; Fabes J Br J Anaesth; 2024 May; 132(5):945-956. PubMed ID: 38368234 [TBL] [Abstract][Full Text] [Related]
7. Analysis of Discrepancies Between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association With Organ Dysfunction and Mortality. Wong AI; Charpignon M; Kim H; Josef C; de Hond AAH; Fojas JJ; Tabaie A; Liu X; Mireles-Cabodevila E; Carvalho L; Kamaleswaran R; Madushani RWMA; Adhikari L; Holder AL; Steyerberg EW; Buchman TG; Lough ME; Celi LA JAMA Netw Open; 2021 Nov; 4(11):e2131674. PubMed ID: 34730820 [TBL] [Abstract][Full Text] [Related]
8. Impact of ethnicity on the accuracy of measurements of oxygen saturations: A retrospective observational cohort study. Bangash MN; Hodson J; Evison F; Patel JM; Johnston AM; Gallier S; Sapey E; Parekh D EClinicalMedicine; 2022 Jun; 48():101428. PubMed ID: 35706489 [TBL] [Abstract][Full Text] [Related]
9. A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients. Ebmeier SJ; Barker M; Bacon M; Beasley RC; Bellomo R; Knee Chong C; Eastwood GM; Gilchrist J; Kagaya H; Pilcher J; Reddy SK; Ridgeon E; Sarma N; Sprogis S; Tanaka A; Tweedie M; Weatherall M; Young PJ Anaesth Intensive Care; 2018 May; 46(3):297-303. PubMed ID: 29716488 [TBL] [Abstract][Full Text] [Related]
10. Agreement between pulse oximetry and arterial oxygen saturation measurement in critical care patients during COVID-19: a cross-sectional study. James A; Petit M; Biancale F; Bougle A; Degos V; Monsel A; Vieillard-Baron A; Constantin JM J Clin Monit Comput; 2023 Aug; 37(4):977-984. PubMed ID: 36670340 [TBL] [Abstract][Full Text] [Related]
11. The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study. Wilson BJ; Cowan HJ; Lord JA; Zuege DJ; Zygun DA BMC Emerg Med; 2010 May; 10():9. PubMed ID: 20444248 [TBL] [Abstract][Full Text] [Related]
12. Pulse Oximetry and Arterial Saturation Difference in Pediatric COVID-19 Patients: Retrospective Analysis by Race. Savorgnan F; Hassan A; Borges N; Acosta S Pediatr Crit Care Med; 2023 Jun; 24(6):458-462. PubMed ID: 36825900 [TBL] [Abstract][Full Text] [Related]
13. Facing SpO Thijssen M; Janssen L; le Noble J; Foudraine N J Clin Monit Comput; 2020 Aug; 34(4):693-698. PubMed ID: 31392655 [TBL] [Abstract][Full Text] [Related]
14. Is pulse oximeter a reliable tool for non-critically ill patients with COVID-19? Gürün Kaya A; Öz M; Akdemir Kalkan İ; Gülten E; Çınar G; Azap A; Kaya A Int J Clin Pract; 2021 Dec; 75(12):e14983. PubMed ID: 34637170 [TBL] [Abstract][Full Text] [Related]
15. Discordance Between Invasive and NonInvasive Oxygen Saturation in Critically Ill COVID-19 Patients. Fox TH; Mazalewski WR; Tran HS; Lindsey T; Krishnan A; Kantrow SP; Happel KI; Janz DR; deBoisblanc BP; Lammi MR J Intensive Care Med; 2023 Dec; 38(12):1151-1157. PubMed ID: 37415515 [TBL] [Abstract][Full Text] [Related]
16. Self-reported Race/Ethnicity and Intraoperative Occult Hypoxemia: A Retrospective Cohort Study. Burnett GW; Stannard B; Wax DB; Lin HM; Pyram-Vincent C; DeMaria S; Levin MA Anesthesiology; 2022 May; 136(5):688-696. PubMed ID: 35231085 [TBL] [Abstract][Full Text] [Related]
17. Racial effects on Masimo pulse oximetry: a laboratory study. Barker SJ; Wilson WC J Clin Monit Comput; 2023 Apr; 37(2):567-574. PubMed ID: 36370242 [TBL] [Abstract][Full Text] [Related]
18. Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort study. Valbuena VSM; Seelye S; Sjoding MW; Valley TS; Dickson RP; Gay SE; Claar D; Prescott HC; Iwashyna TJ BMJ; 2022 Jul; 378():e069775. PubMed ID: 35793817 [TBL] [Abstract][Full Text] [Related]
19. Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study. Hao S; Dempsey K; Matos J; Cox CE; Rotemberg V; Gichoya JW; Kibbe W; Hong C; Wong AI Crit Care Explor; 2024 Sep; 6(9):e1133. PubMed ID: 39268149 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of pulse oximetry in the intensive care unit. Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]