BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 34556210)

  • 1. Label-free triplex DNA-based biosensing of transcription factor using fluorescence resonance energy transfer between N-doped carbon dot and gold nanoparticle.
    Mahani M; Taheri M; Divsar F; Khakbaz F; Nomani A; Ju H
    Anal Chim Acta; 2021 Oct; 1181():338919. PubMed ID: 34556210
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A peptide nucleic acid-regulated fluorescence resonance energy transfer DNA assay based on the use of carbon dots and gold nanoparticles.
    Gao T; Xing S; Xu M; Fu P; Yao J; Zhang X; Zhao Y; Zhao C
    Mikrochim Acta; 2020 Jun; 187(7):375. PubMed ID: 32518969
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A label-free and enzyme-free ultra-sensitive transcription factors biosensor using DNA-templated copper nanoparticles as fluorescent indicator and hairpin DNA cascade reaction as signal amplifier.
    Sha L; Zhang X; Wang G
    Biosens Bioelectron; 2016 Aug; 82():85-92. PubMed ID: 27045526
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Amplified fluorescent sensing of DNA using luminescent carbon dots and AuNPs/GO as a sensing platform: A novel coupling of FRET and DNA hybridization for homogeneous HIV-1 gene detection at femtomolar level.
    Qaddare SH; Salimi A
    Biosens Bioelectron; 2017 Mar; 89(Pt 2):773-780. PubMed ID: 27816581
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Silver ion-stabilized DNA triplexes for completely enzyme-free and sensitive fluorescence detection of transcription factors via catalytic hairpin assembly amplification.
    Qin Y; Li D; Yuan R; Xiang Y
    J Mater Chem B; 2019 Feb; 7(5):763-767. PubMed ID: 32254850
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new nanobiosensor for glucose with high sensitivity and selectivity in serum based on fluorescence resonance Energy transfer (FRET) between CdTe quantum dots and Au nanoparticles.
    Tang B; Cao L; Xu K; Zhuo L; Ge J; Li Q; Yu L
    Chemistry; 2008; 14(12):3637-44. PubMed ID: 18318025
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A fluorescence resonance energy transfer (FRET) biosensor based on graphene quantum dots (GQDs) and gold nanoparticles (AuNPs) for the detection of mecA gene sequence of Staphylococcus aureus.
    Shi J; Chan C; Pang Y; Ye W; Tian F; Lyu J; Zhang Y; Yang M
    Biosens Bioelectron; 2015 May; 67():595-600. PubMed ID: 25288044
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An efficient turn-on fluorescence biosensor for the detection of glutathione based on FRET between N,S dual-doped carbon dots and gold nanoparticles.
    Dong W; Wang R; Gong X; Dong C
    Anal Bioanal Chem; 2019 Oct; 411(25):6687-6695. PubMed ID: 31407048
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fluorescence Resonance Energy Transfer-based Biosensor Composed of Nitrogen-doped Carbon Dots and Gold Nanoparticles for the Highly Sensitive Detection of Organophosphorus Pesticides.
    Gong NC; Li YL; Jiang X; Zheng XF; Wang YY; Huan SY
    Anal Sci; 2016; 32(9):951-6. PubMed ID: 27682399
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasensitive FRET-based aptasensor for interleukin-6 as a biomarker for COVID-19 progression using nitrogen-doped carbon quantum dots and gold nanoparticles.
    Mahani M; Faghihi-Fard M; Divsar F; Torkzadeh-Mahani M; Khakbaz F
    Mikrochim Acta; 2022 Nov; 189(12):472. PubMed ID: 36434394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Dual-Readout Method for Biothiols Detection Based on the NSET of Nitrogen-Doped Carbon Quantum Dots-Au Nanoparticles System.
    Fu X; Gu D; Zhao S; Zhou N; Zhang H
    J Fluoresc; 2017 Sep; 27(5):1597-1605. PubMed ID: 28401410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Immobilization of gold nanoparticles with rhodamine to enhance the fluorescence resonance energy transfer between quantum dots and rhodamine; new method for downstream sensing of infectious bursal disease virus.
    Sabzehparvar F; Rahmani Cherati T; Mohsenifar A; Roodbar Shojaei T; Tabatabaei M
    Spectrochim Acta A Mol Biomol Spectrosc; 2019 Apr; 212():173-179. PubMed ID: 30639602
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Novel single-stranded DNA binding protein-assisted fluorescence aptamer switch based on FRET for homogeneous detection of antibiotics.
    Wang Y; Gan N; Zhou Y; Li T; Cao Y; Chen Y
    Biosens Bioelectron; 2017 Jan; 87():508-513. PubMed ID: 27596250
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Niche nanoparticle-based FRET assay for bleomycin detection via DNA scission.
    Pei H; Zheng Y; Kong R; Xia L; Qu F
    Biosens Bioelectron; 2016 Nov; 85():76-82. PubMed ID: 27155119
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Target-driven switch-on fluorescence aptasensor for trace aflatoxin B1 determination based on highly fluorescent ternary CdZnTe quantum dots.
    Lu X; Wang C; Qian J; Ren C; An K; Wang K
    Anal Chim Acta; 2019 Jan; 1047():163-171. PubMed ID: 30567646
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficient Fluorescence Resonance Energy Transfer between Quantum Dots and Gold Nanoparticles Based on Porous Silicon Photonic Crystal for DNA Detection.
    Zhang H; Lv J; Jia Z
    Sensors (Basel); 2017 May; 17(5):. PubMed ID: 28489033
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sensitive and selective sensing system of metallothioneins based on carbon quantum dots and gold nanoparticles.
    Duan L; Du X; Zhao H; Sun Y; Liu W
    Anal Chim Acta; 2020 Aug; 1125():177-186. PubMed ID: 32674764
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ratiometric enhanced fluorometric determination and imaging of intracellular microRNA-155 by using carbon dots, gold nanoparticles and rhodamine B for signal amplification.
    Hamd-Ghadareh S; Hamah-Ameen BA; Salimi A; Fathi F; Soleimani F
    Mikrochim Acta; 2019 Jun; 186(7):469. PubMed ID: 31240482
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A dual-mode nanosensor based on carbon quantum dots and gold nanoparticles for discriminative detection of glutathione in human plasma.
    Shi Y; Pan Y; Zhang H; Zhang Z; Li MJ; Yi C; Yang M
    Biosens Bioelectron; 2014 Jun; 56():39-45. PubMed ID: 24462829
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Carbon quantum dots as fluorescence resonance energy transfer sensors for organophosphate pesticides determination.
    Wu X; Song Y; Yan X; Zhu C; Ma Y; Du D; Lin Y
    Biosens Bioelectron; 2017 Aug; 94():292-297. PubMed ID: 28315592
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.