These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 34558032)

  • 1. Establishment of a Modular Hemodynamic Simulator for Accurate In Vitro Simulation of Physiological and Pathological Pressure Waveforms in Native and Bioartificial Blood Vessels.
    Helms F; Haverich A; Wilhelmi M; Böer U
    Cardiovasc Eng Technol; 2022 Apr; 13(2):291-306. PubMed ID: 34558032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A New Blood Pulsation Simulator Platform Incorporating Cardiovascular Physiology for Evaluating Radial Pulse Waveform.
    Yang TH; Kim JU; Kim YM; Koo JH; Woo SY
    J Healthc Eng; 2019; 2019():4938063. PubMed ID: 30886685
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms.
    Yang TH; Jo G; Koo JH; Woo SY; Kim JU; Kim YM
    Biomed Eng Online; 2019 Jan; 18(1):1. PubMed ID: 30602383
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Blind identification of the central aortic pressure waveform from multiple peripheral arterial pressure waveforms.
    Swamy G; Ling Q; Li T; Mukkamala R
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1822-5. PubMed ID: 17945671
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Blind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms.
    Swamy G; Ling Q; Li T; Mukkamala R
    Am J Physiol Heart Circ Physiol; 2007 May; 292(5):H2257-64. PubMed ID: 17208992
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neonatal aortic arch hemodynamics and perfusion during cardiopulmonary bypass.
    Pekkan K; Dur O; Sundareswaran K; Kanter K; Fogel M; Yoganathan A; Undar A
    J Biomech Eng; 2008 Dec; 130(6):061012. PubMed ID: 19045541
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simplified distributed-parameter model of brachial-radial arteries for noninvasive determination of mechanical characteristics of vessel.
    Ferreira AS; Filho JB; Souza MN
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1814-7. PubMed ID: 17945669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure.
    Varble N; Day S; Phillips D; Mix D; Schwarz K; Illig KA; Chandra A
    J Vasc Surg; 2014 May; 59(5):1410-7. PubMed ID: 23845661
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Coronary arteries hemodynamics: effect of arterial geometry on hemodynamic parameters causing atherosclerosis.
    Wong KKL; Wu J; Liu G; Huang W; Ghista DN
    Med Biol Eng Comput; 2020 Aug; 58(8):1831-1843. PubMed ID: 32519006
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of an Experimental and Digital Cardiovascular Arterial Model for Transient Hemodynamic and Postural Change Studies: "A Preliminary Framework Analysis".
    Hewlin RL; Kizito JP
    Cardiovasc Eng Technol; 2018 Mar; 9(1):1-31. PubMed ID: 29124548
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimation of the aortic pressure waveform from a radial artery pressure waveform via an adaptive transfer function: Feasibility demonstration in swine.
    Swamy G; Xu D; Mukkamala R
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2362-4. PubMed ID: 19965187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transluminal compression increases mechanical stability, stiffness and endothelialization capacity of fibrin-based bioartificial blood vessels.
    Helms F; Haverich A; Böer U; Wilhelmi M
    J Mech Behav Biomed Mater; 2021 Dec; 124():104835. PubMed ID: 34530301
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Personalized Hemodynamic Modeling of the Human Cardiovascular System: A Reduced-Order Computing Model.
    Zhang X; Wu D; Miao F; Liu H; Li Y
    IEEE Trans Biomed Eng; 2020 Oct; 67(10):2754-2764. PubMed ID: 32142412
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of arterial mechanical properties from aortic and tonometric arterial pressure waveforms.
    Sugimachi M; Kawada T; Shishido T; Matsumoto N; Alexander J; Sunagawa K
    Methods Inf Med; 1997 Dec; 36(4-5):250-3. PubMed ID: 9470370
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The noninvasive estimation of central aortic blood pressure in patients with aortic stenosis.
    Rajani R; Chowienczyk P; Redwood S; Guilcher A; Chambers JB
    J Hypertens; 2008 Dec; 26(12):2381-8. PubMed ID: 19008716
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro cardiovascular system emulator (bioreactor) for the simulation of normal and diseased conditions with and without mechanical circulatory support.
    Ruiz P; Rezaienia MA; Rahideh A; Keeble TR; Rothman MT; Korakianitis T
    Artif Organs; 2013 Jun; 37(6):549-60. PubMed ID: 23758568
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 3-Layered Bioartificial Blood Vessel with Physiological Wall Architecture Generated by Mechanical Stimulation.
    Helms F; Lau S; Aper T; Zippusch S; Klingenberg M; Haverich A; Wilhelmi M; Böer U
    Ann Biomed Eng; 2021 Sep; 49(9):2066-2079. PubMed ID: 33483842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer simulation of blood flow in the human arm.
    Balar SD; Rogge TR; Young DF
    J Biomech; 1989; 22(6-7):691-7. PubMed ID: 2808450
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The analysis of radial artery pressure waveforms using 4 element model].
    Hayashi K; Sigemi K
    Masui; 2003 Sep; 52(9):1011-20. PubMed ID: 14531267
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of exercise on hemodynamic conditions in the abdominal aorta.
    Taylor CA; Hughes TJ; Zarins CK
    J Vasc Surg; 1999 Jun; 29(6):1077-89. PubMed ID: 10359942
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.