These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
156 related articles for article (PubMed ID: 34560678)
1. Adaptation of stochastic microdosimetric kinetic model to hypoxia for hypo-fractionated multi-ion therapy treatment planning. Inaniwa T; Kanematsu N; Shinoto M; Koto M; Yamada S Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34560678 [TBL] [Abstract][Full Text] [Related]
2. Experimental validation of stochastic microdosimetric kinetic model for multi-ion therapy treatment planning with helium-, carbon-, oxygen-, and neon-ion beams. Inaniwa T; Suzuki M; Hyun Lee S; Mizushima K; Iwata Y; Kanematsu N; Shirai T Phys Med Biol; 2020 Feb; 65(4):045005. PubMed ID: 31968318 [TBL] [Abstract][Full Text] [Related]
3. Effects of cellular radioresponse on therapeutic helium-, carbon-, oxygen-, and neon-ion beams: a simulation study. Masuda T; Inaniwa T Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38232394 [No Abstract] [Full Text] [Related]
4. Spot-scanning hadron arc (SHArc) therapy: A proof of concept using single- and multi-ion strategies with helium, carbon, oxygen, and neon ions. Mein S; Kopp B; Tessonnier T; Liermann J; Abdollahi A; Debus J; Haberer T; Mairani A Med Phys; 2022 Sep; 49(9):6082-6097. PubMed ID: 35717613 [TBL] [Abstract][Full Text] [Related]
5. Event-by-event approach to the oxygen-effect-incorporated stochastic microdosimetric kinetic model for hypofractionated multi-ion therapy. Inaniwa T; Kanematsu N J Radiat Res; 2023 Jul; 64(4):685-692. PubMed ID: 37421442 [TBL] [Abstract][Full Text] [Related]
6. Adaptation of stochastic microdosimetric kinetic model for charged-particle therapy treatment planning. Inaniwa T; Kanematsu N Phys Med Biol; 2018 May; 63(9):095011. PubMed ID: 29726401 [TBL] [Abstract][Full Text] [Related]
7. Adaptation of the microdosimetric kinetic model to hypoxia. Bopp C; Hirayama R; Inaniwa T; Kitagawa A; Matsufuji N; Noda K Phys Med Biol; 2016 Nov; 61(21):7586-7599. PubMed ID: 27716637 [TBL] [Abstract][Full Text] [Related]
8. Estimating the biological effects of helium, carbon, oxygen, and neon ion beams using 3D silicon microdosimeters. Lee SH; Mizushima K; Kohno R; Iwata Y; Yonai S; Shirai T; Pan VA; Bolst D; Tran LT; Rosenfeld AB; Suzuki M; Inaniwa T Phys Med Biol; 2021 Feb; 66(4):045017. PubMed ID: 33361575 [TBL] [Abstract][Full Text] [Related]
9. Tumour control in ion beam radiotherapy with different ions in the presence of hypoxia: an oxygen enhancement ratio model based on the microdosimetric kinetic model. Strigari L; Torriani F; Manganaro L; Inaniwa T; Dalmasso F; Cirio R; Attili A Phys Med Biol; 2018 Mar; 63(6):065012. PubMed ID: 28862152 [TBL] [Abstract][Full Text] [Related]
10. Application of lung substitute material as ripple filter for multi-ion therapy with helium-, carbon-, oxygen-, and neon-ion beams. Inaniwa T; Abe Y; Suzuki M; Lee SH; Mizushima K; Nakaji T; Sakata D; Sato S; Iwata Y; Kanematsu N; Shirai T Phys Med Biol; 2021 Feb; 66(5):. PubMed ID: 33477116 [TBL] [Abstract][Full Text] [Related]
11. Nuclear-interaction correction for patient dose calculations in treatment planning of helium-, carbon-, oxygen-, and neon-ion beams. Inaniwa T; Lee SH; Mizushima K; Sakata D; Iwata Y; Kanematsu N; Shirai T Phys Med Biol; 2020 Jan; 65(2):025004. PubMed ID: 31816612 [TBL] [Abstract][Full Text] [Related]
12. Inactivation of aerobic and hypoxic cells from three different cell lines by accelerated (3)He-, (12)C- and (20)Ne-ion beams. Furusawa Y; Fukutsu K; Aoki M; Itsukaichi H; Eguchi-Kasai K; Ohara H; Yatagai F; Kanai T; Ando K Radiat Res; 2000 Nov; 154(5):485-96. PubMed ID: 11025645 [TBL] [Abstract][Full Text] [Related]
13. A heavy particle comparative study. Part III: OER and RBE. Raju MR; Amols HI; Bain E; Carpenter SG; Cox RA; Robertson JB Br J Radiol; 1978 Sep; 51(609):712-9. PubMed ID: 698514 [TBL] [Abstract][Full Text] [Related]
15. The relative biological effectiveness for carbon, nitrogen, and oxygen ion beams using passive and scanning techniques evaluated with fully 3D silicon microdosimeters. Tran LT; Bolst D; Guatelli S; Pogossov A; Petasecca M; Lerch MLF; Chartier L; Prokopovich DA; Reinhard MI; Povoli M; Kok A; Perevertaylo VL; Matsufuji N; Kanai T; Jackson M; Rosenfeld AB Med Phys; 2018 May; 45(5):2299-2308. PubMed ID: 29572856 [TBL] [Abstract][Full Text] [Related]
16. The influence of hypoxia on LET and RBE relationships with implications for ultra-high dose rates and FLASH modelling. Jones B Phys Med Biol; 2022 Jun; 67(12):. PubMed ID: 35545062 [No Abstract] [Full Text] [Related]
17. Roadmap: helium ion therapy. Mairani A; Mein S; Blakely E; Debus J; Durante M; Ferrari A; Fuchs H; Georg D; Grosshans DR; Guan F; Haberer T; Harrabi S; Horst F; Inaniwa T; Karger CP; Mohan R; Paganetti H; Parodi K; Sala P; Schuy C; Tessonnier T; Titt U; Weber U Phys Med Biol; 2022 Aug; 67(15):. PubMed ID: 35395649 [TBL] [Abstract][Full Text] [Related]
18. Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams. Dokic I; Mairani A; Niklas M; Zimmermann F; Chaudhri N; Krunic D; Tessonnier T; Ferrari A; Parodi K; Jäkel O; Debus J; Haberer T; Abdollahi A Oncotarget; 2016 Aug; 7(35):56676-56689. PubMed ID: 27494855 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of SCCVII tumor cell survival in clamped and non-clamped solid tumors exposed to carbon-ion beams in comparison to X-rays. Hirayama R; Uzawa A; Takase N; Matsumoto Y; Noguchi M; Koda K; Ozaki M; Yamashita K; Li H; Kase Y; Matsufuji N; Koike S; Masunaga S; Ando K; Okayasu R; Furusawa Y Mutat Res; 2013 Aug; 756(1-2):146-51. PubMed ID: 23735375 [TBL] [Abstract][Full Text] [Related]
20. Radiobiology with heavy charged particles: a historical review. Skarsgard LD Phys Med; 1998 Jul; 14 Suppl 1():1-19. PubMed ID: 11542635 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]