193 related articles for article (PubMed ID: 34561504)

  • 1. Optimization of collimator angles in dual-arc volumetric modulated arc therapy planning for whole-brain radiotherapy with hippocampus and inner ear sparing.
    Sun W; Chen K; Li Y; Xia W; Dong L; Shi Y; Ge C; Yang X; Wang L; Wang H
    Sci Rep; 2021 Sep; 11(1):19035. PubMed ID: 34561504
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Potential for reduced radiation-induced toxicity using intensity-modulated arc therapy for whole-brain radiotherapy with hippocampal sparing.
    Pokhrel D; Sood S; Lominska C; Kumar P; Badkul R; Jiang H; Wang F
    J Appl Clin Med Phys; 2015 Sep; 16(5):131–141. PubMed ID: 26699321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Volumetric modulated arc therapy (VMAT) for hippocampal-avoidance whole brain radiation therapy: planning comparison with Dual-arc and Split-arc partial-field techniques.
    Yuen AHL; Wu PM; Li AKL; Mak PCY
    Radiat Oncol; 2020 Feb; 15(1):42. PubMed ID: 32070385
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric evaluation of four whole brain radiation therapy approaches with hippocampus and inner ear avoidance and simultaneous integrated boost for limited brain metastases.
    Jiang A; Sun W; Zhao F; Wu Z; Shang D; Yu Q; Wang S; Zhu J; Yang F; Yuan S
    Radiat Oncol; 2019 Mar; 14(1):46. PubMed ID: 30876444
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Capabilities and Characteristics of Helical Tomotherapy and Co-Planar Dual Arcs Volumetric-Modulated arc Therapy Associated with Hippocampal Sparing During Prophylactic Cranial Irradiation.
    Wang D; Ma X; Fu L; Gu J; Bai T; Yin Y; Li B; Zhu J
    Technol Cancer Res Treat; 2021; 20():15330338211043975. PubMed ID: 34632869
    [No Abstract]   [Full Text] [Related]  

  • 6. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy.
    Pokhrel D; Sood S; McClinton C; Shen X; Lominska C; Saleh H; Badkul R; Jiang H; Mitchell M; Wang F
    Med Dosim; 2016 Winter; 41(4):315-322. PubMed ID: 27692518
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of multi-criteria optimization (MCO) for volumetric modulated arc therapy (VMAT) in hippocampal avoidance whole brain radiation therapy (HA-WBRT).
    Zieminski S; Khandekar M; Wang Y
    J Appl Clin Med Phys; 2018 Mar; 19(2):184-190. PubMed ID: 29411526
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variations in dosimetric distribution and plan complexity with collimator angles in hypofractionated volumetric arc radiotherapy for treating prostate cancer.
    Li MH; Huang SF; Chang CC; Lin JC; Tsai JT
    J Appl Clin Med Phys; 2018 Mar; 19(2):93-102. PubMed ID: 29322625
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of the simulated half leaf width of a multileaf collimator on volumetric modulated arc therapy plan quality in hippocampal avoidance whole-brain radiotherapy.
    Li MH; Chen LJ; Chang CC; Tsai JT; Lin JC
    J Appl Clin Med Phys; 2022 May; 23(5):e13575. PubMed ID: 35239259
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases.
    Xu Y; Xu Y; Men K; Xiao J; Dai J
    Radiat Oncol; 2022 May; 17(1):86. PubMed ID: 35526019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sparing the hippocampus and the hypothalamic- pituitary region during whole brain radiotherapy: a volumetric modulated arc therapy planning study.
    Mehta P; Janssen S; Fahlbusch FB; Schmid SM; Gebauer J; Cremers F; Ziemann C; Tartz M; Rades D
    BMC Cancer; 2020 Jun; 20(1):610. PubMed ID: 32605648
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric study of different radiotherapy planning approaches for hippocampal avoidance whole-brain radiation therapy (HA-WBRT) based on fused CT and MRI imaging.
    Wang BH; Hua W; Gu X; Wang XL; Li J; Liu LQ; Huang YX
    Australas Phys Eng Sci Med; 2015 Dec; 38(4):767-75. PubMed ID: 26577714
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hippocampal sparing for brain tumor radiotherapy: A retrospective study comparing intensity-modulated radiotherapy and volumetric-modulated arc therapy.
    Soydemir GP; Bilici N; Tiken EE; Balkanay AY; Sisman AF; Karacetin D
    J Cancer Res Ther; 2021; 17(1):99-105. PubMed ID: 33723139
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inclined head position improves dose distribution during hippocampal-sparing whole brain radiotherapy using VMAT.
    Kim KS; Seo SJ; Lee J; Seok JY; Hong JW; Chung JB; Kim E; Choi N; Eom KY; Kim JS; Kim IA
    Strahlenther Onkol; 2016 Jul; 192(7):473-80. PubMed ID: 27221313
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric comparison between RapidArc and HyperArc in hippocampal-sparing whole-brain radiotherapy with a simultaneous integrated boost.
    Kim J; Kim TG; Park B; Kim H; Song YG; Lee HW; Kim YZ; Ji JH; Kim SH; Kim SM; Lee JH; Kim H
    Med Dosim; 2024 Summer; 49(2):69-76. PubMed ID: 37718172
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automatic planning on hippocampal avoidance whole-brain radiotherapy.
    Wang S; Zheng D; Zhang C; Ma R; Bennion NR; Lei Y; Zhu X; Enke CA; Zhou S
    Med Dosim; 2017 Spring; 42(1):63-68. PubMed ID: 28237294
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at risk.
    Sood S; Pokhrel D; McClinton C; Lominska C; Badkul R; Jiang H; Wang F
    Med Dosim; 2017 Winter; 42(4):375-383. PubMed ID: 28822604
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hippocampal sparing approach in fractionated stereotactic brain VMAT radio therapy: A retrospective feasibility analysis.
    Daniela Falco M; Giancaterino S; D'Andrea M; Gimenez De Lorenzo R; Trignani M; Caravatta L; Di Carlo C; Di Biase S; Allajbej A; Genovesi D
    J Appl Clin Med Phys; 2018 Jan; 19(1):86-93. PubMed ID: 29125239
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved plan quality with automated radiotherapy planning for whole brain with hippocampus sparing: a comparison to the RTOG 0933 trial.
    Krayenbuehl J; Di Martino M; Guckenberger M; Andratschke N
    Radiat Oncol; 2017 Oct; 12(1):161. PubMed ID: 28969706
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery.
    Molinier J; Kerr C; Simeon S; Ailleres N; Charissoux M; Azria D; Fenoglietto P
    J Appl Clin Med Phys; 2016 Jan; 17(1):92-101. PubMed ID: 26894335
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]