147 related articles for article (PubMed ID: 34566290)
21. Characterization of mechanical and radiation isocenter on an MR-guided radiotherapy (MRgRT) Linac. Bassiri N; Bayouth JE; Mittauer KE J Appl Clin Med Phys; 2023 Nov; 24(11):e14111. PubMed ID: 37535938 [TBL] [Abstract][Full Text] [Related]
22. Comprehensive radiation and imaging isocenter verification using NIPAM kV-CBCT dosimetry. Pant K; Umeh C; Oldham M; Floyd S; Giles W; Adamson J Med Phys; 2020 Mar; 47(3):927-936. PubMed ID: 31899806 [TBL] [Abstract][Full Text] [Related]
23. A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Du W; Yang J; Luo D; Martel M Med Phys; 2010 May; 37(5):2256-63. PubMed ID: 20527559 [TBL] [Abstract][Full Text] [Related]
24. Improved accuracy for noncoplanar radiotherapy: an EPID-based method for submillimeter alignment of linear accelerator table rotation with MV isocenter. Nyflot MJ; Cao N; Meyer J; Ford EC J Appl Clin Med Phys; 2014 Mar; 15(2):4682. PubMed ID: 24710457 [TBL] [Abstract][Full Text] [Related]
25. Efficient quality assurance method with automated data acquisition of a single phantom setup to determine radiation and imaging isocenter congruence. Kang H; Patel R; Roeske JC J Appl Clin Med Phys; 2019 Oct; 20(10):127-133. PubMed ID: 31535781 [TBL] [Abstract][Full Text] [Related]
26. A study of Winston-Lutz test on two different electronic portal imaging devices and with low energy imaging. Ravindran PB Australas Phys Eng Sci Med; 2016 Sep; 39(3):677-85. PubMed ID: 27435984 [TBL] [Abstract][Full Text] [Related]
27. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy. Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431 [TBL] [Abstract][Full Text] [Related]
28. [Development of an automated method for analysis of Winston-Lutz test results using digital radiography and photostimulable storage phosphor]. Nagafuchi K; Kawata H; Nashiki K; Ohkura S; Hayashida K; Kawahara T; Ohishi A; Mizoguchi A; Saida Y Nihon Hoshasen Gijutsu Gakkai Zasshi; 2013 Nov; 69(11):1266-73. PubMed ID: 24256650 [TBL] [Abstract][Full Text] [Related]
29. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator. Riis HL; Zimmermann SJ; Hjelm-Hansen M Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302 [TBL] [Abstract][Full Text] [Related]
30. Implementing corrections of isocentric shifts for the stereotactic irradiation of cerebral targets: Clinical validation. Wegener S; Schindhelm R; Sauer OA J Appl Clin Med Phys; 2022 May; 23(5):e13577. PubMed ID: 35234345 [TBL] [Abstract][Full Text] [Related]
31. Detection of rotational errors in single-isocenter multiple-target radiosurgery: Is a routine off-axis Winston-Lutz test necessary? Pudsey LMM; Biasi G; Ralston A; Rosenfeld A; Poder J J Appl Clin Med Phys; 2022 Sep; 23(9):e13665. PubMed ID: 35713881 [TBL] [Abstract][Full Text] [Related]
32. Optical emission-based phantom to verify coincidence of radiotherapy and imaging isocenters on an MR-linac. Andreozzi JM; Brůža P; Cammin J; Alexander DA; Pogue BW; Green O; Gladstone DJ J Appl Clin Med Phys; 2021 Sep; 22(9):252-261. PubMed ID: 34409766 [TBL] [Abstract][Full Text] [Related]
33. SU-E-T-184: LINAC Commissioning Measurements Utilizing the Cylindrical Arc Check Phantom. Aristophanous M; Balter P; Martel M; Murray N; Court L Med Phys; 2012 Jun; 39(6Part12):3745. PubMed ID: 28517831 [TBL] [Abstract][Full Text] [Related]
34. Assessment of an Elekta Versa HD linear accelerator for stereotactic radiosurgery with circular cone collimators. Zhang M; Fan Q; Lei Y; Thapa B; Padula G J Xray Sci Technol; 2020; 28(1):71-82. PubMed ID: 31904001 [TBL] [Abstract][Full Text] [Related]
35. An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery. Capaldi DPI; Skinner LB; Dubrowski P; Yu AS Phys Med Biol; 2020 Jun; 65(11):115006. PubMed ID: 32235050 [TBL] [Abstract][Full Text] [Related]
36. Evaluation of the RUBY modular QA phantom for planar and non-coplanar VMAT and stereotactic radiations. Poppinga D; Kretschmer J; Brodbek L; Meyners J; Poppe B; Looe HK J Appl Clin Med Phys; 2020 Oct; 21(10):69-79. PubMed ID: 32797670 [TBL] [Abstract][Full Text] [Related]
37. Quality assurance for cancer patient safety: Clinical assessment for precise angles in linac during radiation therapy. Salahuddin S; Buzdar SA; Iqbal K; Azam MA; Aslam M; Altaf S; Ikhlaq A; Mustafa MU; Strigari L Tumori; 2024 Oct; 110(5):366-374. PubMed ID: 39096026 [TBL] [Abstract][Full Text] [Related]
38. SU-E-T-24: Development and Implementation of an Automated Algorithm to Determine Radiation Isocenter, Radiation vs. Light Field Coincidence, and Analyze Strip Tests. Hyer D; Mart C Med Phys; 2012 Jun; 39(6Part9):3707. PubMed ID: 28519067 [TBL] [Abstract][Full Text] [Related]
39. Towards zero radiation isocentre size: minimising radiation beam isocentricity on Elekta linear accelerators by means of optimising look-up tables. Chojnowski JM; Sykes JR; Thwaites DI Phys Eng Sci Med; 2021 Jun; 44(2):557-563. PubMed ID: 33591539 [TBL] [Abstract][Full Text] [Related]
40. Automatic measurement of beam-positioning accuracy at off-isocenter positions. Ono T; Kido T; Nakamura M; Iramina H; Kakino R; Mizowaki T J Appl Clin Med Phys; 2023 Mar; 24(3):e13844. PubMed ID: 36420973 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]