These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 34567665)

  • 41. Ultrasensitive detection of HIV-1 p24 antigen by a hybrid nanomechanical-optoplasmonic platform with potential for detecting HIV-1 at first week after infection.
    Kosaka PM; Pini V; Calleja M; Tamayo J
    PLoS One; 2017; 12(2):e0171899. PubMed ID: 28199410
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Surface-Enhanced Raman Scattering-Based Dual-Flow Lateral Flow Assay Sensor for the Ultrasensitive Detection of the Thyroid-Stimulating Hormone.
    Kim K; Han DK; Choi N; Kim SH; Joung Y; Kim K; Ho NT; Joo SW; Choo J
    Anal Chem; 2021 May; 93(17):6673-6681. PubMed ID: 33878867
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Ultra-Sensitive and Semi-Quantitative Vertical Flow Assay for the Rapid Detection of Interleukin-6 in Inflammatory Diseases.
    Lei R; Arain H; Obaid M; Sabhnani N; Mohan C
    Biosensors (Basel); 2022 Sep; 12(9):. PubMed ID: 36140141
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Advantages of time-resolved fluorescent nanobeads compared with fluorescent submicrospheres, quantum dots, and colloidal gold as label in lateral flow assays for detection of ractopamine.
    Hu LM; Luo K; Xia J; Xu GM; Wu CH; Han JJ; Zhang GG; Liu M; Lai WH
    Biosens Bioelectron; 2017 May; 91():95-103. PubMed ID: 28006689
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Development of quantitative immunochromatographic assay for rapid and sensitive detection of carbohydrate antigen 19-9 (CA 19-9) in human plasma.
    Baryeh K; Takalkar S; Lund M; Liu G
    J Pharm Biomed Anal; 2017 Nov; 146():285-291. PubMed ID: 28898765
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Simple diffusion-constrained immunoassay for p24 protein with the sensitivity of nucleic acid amplification for detecting acute HIV infection.
    Chang L; Song L; Fournier DR; Kan CW; Patel PP; Ferrell EP; Pink BA; Minnehan KA; Hanlon DW; Duffy DC; Wilson DH
    J Virol Methods; 2013 Mar; 188(1-2):153-60. PubMed ID: 23036750
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Point-Of-Care p24 Infant Testing for HIV May Increase Patient Identification despite Low Sensitivity.
    Meggi B; Bollinger T; Mabunda N; Vubil A; Tobaiwa O; Quevedo JI; Loquiha O; Vojnov L; Peter TF; Jani IV
    PLoS One; 2017; 12(1):e0169497. PubMed ID: 28060886
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Analytical Tools to Improve Optimization Procedures for Lateral Flow Assays.
    Hsieh HV; Dantzler JL; Weigl BH
    Diagnostics (Basel); 2017 May; 7(2):. PubMed ID: 28555034
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Membrane-Free Lateral Flow Assay with the Active Control of Fluid Transport for Ultrasensitive Cardiac Biomarker Detection.
    Strohmaier-Nguyen D; Horn C; Baeumner AJ
    Anal Chem; 2024 May; 96(18):7014-7021. PubMed ID: 38659215
    [TBL] [Abstract][Full Text] [Related]  

  • 50. p24 Antigen detection assay modified with a booster step for diagnosis and monitoring of human immunodeficiency virus type 1 infection.
    Sutthent R; Gaudart N; Chokpaibulkit K; Tanliang N; Kanoksinsombath C; Chaisilwatana P
    J Clin Microbiol; 2003 Mar; 41(3):1016-22. PubMed ID: 12624024
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A portable and universal upconversion nanoparticle-based lateral flow assay platform for point-of-care testing.
    Gong Y; Zheng Y; Jin B; You M; Wang J; Li X; Lin M; Xu F; Li F
    Talanta; 2019 Aug; 201():126-133. PubMed ID: 31122402
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Oligonucleotide-linked gold nanoparticle aggregates for enhanced sensitivity in lateral flow assays.
    Hu J; Wang L; Li F; Han YL; Lin M; Lu TJ; Xu F
    Lab Chip; 2013 Nov; 13(22):4352-7. PubMed ID: 24056409
    [TBL] [Abstract][Full Text] [Related]  

  • 53. An Ultrasensitive Electrochemical Immunosensor for HIV p24 Based on Fe₃O₄@SiO₂ Nanomagnetic Probes and Nanogold Colloid-Labeled Enzyme-Antibody Copolymer as Signal Tag.
    Gan N; Du X; Cao Y; Hu F; Li T; Jiang Q
    Materials (Basel); 2013 Mar; 6(4):1255-1269. PubMed ID: 28809208
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT).
    Workman S; Wells SK; Pau CP; Owen SM; Dong XF; LaBorde R; Granade TC
    J Virol Methods; 2009 Sep; 160(1-2):14-21. PubMed ID: 19482361
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Potential of the immune complex transfer enzyme immunoassay for antigens and antibodies to improve the sensitivity and its limitations.
    Ishikawa E; Ishikawa S; Hashida S; Hashinaka K
    J Clin Lab Anal; 1998; 12(3):154-61. PubMed ID: 9591702
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.
    Stone M; Bainbridge J; Sanchez AM; Keating SM; Pappas A; Rountree W; Todd C; Bakkour S; Manak M; Peel SA; Coombs RW; Ramos EM; Shriver MK; Contestable P; Nair SV; Wilson DH; Stengelin M; Murphy G; Hewlett I; Denny TN; Busch MP
    J Clin Microbiol; 2018 Aug; 56(8):. PubMed ID: 29793968
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Luminescent lanthanide nanoparticle-based imaging enables ultra-sensitive, quantitative and multiplexed
    Mousseau F; Féraudet Tarisse C; Simon S; Gacoin T; Alexandrou A; Bouzigues CI
    Nanoscale; 2021 Sep; 13(35):14814-14824. PubMed ID: 34533151
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A SERS-based lateral flow assay biosensor for highly sensitive detection of HIV-1 DNA.
    Fu X; Cheng Z; Yu J; Choo P; Chen L; Choo J
    Biosens Bioelectron; 2016 Apr; 78():530-537. PubMed ID: 26669705
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Lateral flow assay ruler for quantitative and rapid point-of-care testing.
    Li Z; Chen H; Wang P
    Analyst; 2019 May; 144(10):3314-3322. PubMed ID: 30968883
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparative Study of Gold and Carbon Nanoparticles in Nucleic Acid Lateral Flow Assay.
    Porras JC; Bernuz M; Marfa J; Pallares-Rusiñol A; Martí M; Pividori MI
    Nanomaterials (Basel); 2021 Mar; 11(3):. PubMed ID: 33804266
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.