BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 34569437)

  • 1. A Case Study on the Effects of Foam and Seat Pan Inclination on the Deformation of Seated Buttocks Using MRI.
    Wang X; Savonnet L; Capbern L; Duprey S
    IISE Trans Occup Ergon Hum Factors; 2021; 9(1):23-32. PubMed ID: 34569437
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Deformation of the gluteal soft tissues during sitting.
    Al-Dirini RM; Reed MP; Thewlis D
    Clin Biomech (Bristol, Avon); 2015 Aug; 30(7):662-8. PubMed ID: 26032324
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantifying the in vivo quasi-static response to loading of sub-dermal tissues in the human buttock using magnetic resonance imaging.
    Al-Dirini RMA; Nisyrios J; Reed MP; Thewlis D
    Clin Biomech (Bristol, Avon); 2017 Dec; 50():70-77. PubMed ID: 28987874
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3-dimensional buttocks response to sitting: a case report.
    Sonenblum SE; Sprigle SH; Cathcart JM; Winder RJ
    J Tissue Viability; 2013 Feb; 22(1):12-8. PubMed ID: 23266211
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Seat-interface pressures on various thicknesses of foam wheelchair cushions: a finite modeling approach.
    Ragan R; Kernozek TW; Bidar M; Matheson JW
    Arch Phys Med Rehabil; 2002 Jun; 83(6):872-5. PubMed ID: 12048671
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 3D anatomy and deformation of the seated buttocks.
    Sonenblum SE; Sprigle SH; Cathcart JM; Winder RJ
    J Tissue Viability; 2015 May; 24(2):51-61. PubMed ID: 25935874
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Deep tissue loads in the seated buttocks on an off-loading wheelchair cushion versus air-cell-based and foam cushions: finite element studies.
    Peko Cohen L; Gefen A
    Int Wound J; 2017 Dec; 14(6):1327-1334. PubMed ID: 29024413
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the effect of trunk tilt on compressive soft tissue deformations under the ischial tuberosities using weight-bearing MRI.
    Shabshin N; Ougortsin V; Zoizner G; Gefen A
    Clin Biomech (Bristol, Avon); 2010 Jun; 25(5):402-8. PubMed ID: 20188448
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development and Validation of a High Anatomical Fidelity FE Model for the Buttock and Thigh of a Seated Individual.
    Al-Dirini RM; Reed MP; Hu J; Thewlis D
    Ann Biomed Eng; 2016 Sep; 44(9):2805-16. PubMed ID: 26857008
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PIPER adult comfort: an open-source full body human body model for seating comfort assessment and its validation under static loading conditions.
    Liu S; Beillas P; Ding L; Wang X
    Front Bioeng Biotechnol; 2023; 11():1170768. PubMed ID: 37324425
    [No Abstract]   [Full Text] [Related]  

  • 11. Sitting with adjustable ischial and back supports: biomechanical changes.
    Makhsous M; Lin F; Hendrix RW; Hepler M; Zhang LQ
    Spine (Phila Pa 1976); 2003 Jun; 28(11):1113-21; discussion 1121-2. PubMed ID: 12782977
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Subcutaneous Fat Thickness Remarkably Influences Contact Pressure and Load Distribution of Buttock in Seated Posture.
    Wang K; Chen Y; Huang S; Wang L; Niu W
    J Healthc Eng; 2021; 2021():4496416. PubMed ID: 34900189
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of the seat cushion contour and the sitting posture on surface pressure distribution and comfort during seated work.
    Li W; Mo R; Yu S; Chu J; Hu Y; Wang L
    Int J Occup Med Environ Health; 2020 Sep; 33(5):675-689. PubMed ID: 32716013
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determining frictional properties of pants and cushion cover materials using human soft tissue and a rigid sled and how they affect seated shear forces.
    Scott J; Reid Bush T
    J Biomech; 2023 Jan; 147():111450. PubMed ID: 36680889
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring the impact of cushion design on buttocks tissue deformation: An MRI approach.
    Sonenblum SE; Ma J; Sprigle SH; Hetzel TR; McKay Cathcart J
    J Tissue Viability; 2018 Aug; 27(3):162-172. PubMed ID: 29804800
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of prolonged sitting on body-seat contact pressures among quay crane operators: A pilot study.
    Pau M; Leban B; Fadda P; Fancello G; Nussbaum MA
    Work; 2016 Nov; 55(3):605-611. PubMed ID: 27814319
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of mechanical conditions in sub-dermal tissues during sitting: a combined experimental-MRI and finite element approach.
    Linder-Ganz E; Shabshin N; Itzchak Y; Gefen A
    J Biomech; 2007; 40(7):1443-54. PubMed ID: 16920122
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of sacral sitting in a wheelchair on the distribution of contact pressure on the buttocks and back and shear force on the ischial region.
    Kamegaya T
    J Phys Ther Sci; 2016 Oct; 28(10):2830-2833. PubMed ID: 27821944
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Seated buttocks anatomy and its impact on biomechanical risk.
    Sonenblum SE; Seol D; Sprigle SH; Cathcart JM
    J Tissue Viability; 2020 May; 29(2):69-75. PubMed ID: 32008891
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A parametric investigation on seat/occupant contact forces and their relationship with initially perceived discomfort using a configurable seat.
    Wang X; Cardoso M; Theodorakos I; Beurier G
    Ergonomics; 2019 Jul; 62(7):891-902. PubMed ID: 30912482
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.