245 related articles for article (PubMed ID: 34577328)
1. Analysis of Impact of Natural Ventilation Strategies in Ventilation Rates and Indoor Environmental Acoustics Using Sensor Measurement Data in Educational Buildings.
de la Hoz-Torres ML; Aguilar AJ; Ruiz DP; Martínez-Aires MD
Sensors (Basel); 2021 Sep; 21(18):. PubMed ID: 34577328
[TBL] [Abstract][Full Text] [Related]
2. Monitoring and Assessment of Indoor Environmental Conditions after the Implementation of COVID-19-Based Ventilation Strategies in an Educational Building in Southern Spain.
Aguilar AJ; de la Hoz-Torres ML; Martínez-Aires MD; Ruiz DP
Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770530
[TBL] [Abstract][Full Text] [Related]
3. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study.
Sakellaris IA; Saraga DE; Mandin C; Roda C; Fossati S; de Kluizenaar Y; Carrer P; Dimitroulopoulou S; Mihucz VG; Szigeti T; Hänninen O; de Oliveira Fernandes E; Bartzis JG; Bluyssen PM
Int J Environ Res Public Health; 2016 Apr; 13(5):. PubMed ID: 27120608
[TBL] [Abstract][Full Text] [Related]
4. Monitoring and Assessment of Indoor Environmental Conditions in Educational Building Using Building Information Modelling Methodology.
Aguilar AJ; de la Hoz-Torres ML; Ruiz DP; Martínez-Aires MD
Int J Environ Res Public Health; 2022 Oct; 19(21):. PubMed ID: 36360631
[TBL] [Abstract][Full Text] [Related]
5. Reopening higher education buildings in post-epidemic COVID-19 scenario: monitoring and assessment of indoor environmental quality after implementing ventilation protocols in Spain and Portugal.
de la Hoz-Torres ML; Aguilar AJ; Costa N; Arezes P; Ruiz DP; Martínez-Aires MD
Indoor Air; 2022 May; 32(5):e13040. PubMed ID: 35622718
[TBL] [Abstract][Full Text] [Related]
6. Indoor environmental quality in school buildings, and the health and wellbeing of students.
Turunen M; Toyinbo O; Putus T; Nevalainen A; Shaughnessy R; Haverinen-Shaughnessy U
Int J Hyg Environ Health; 2014 Sep; 217(7):733-9. PubMed ID: 24709335
[TBL] [Abstract][Full Text] [Related]
7. Indoor air quality in a middle school, Part I: Use of CO2 as a tracer for effective ventilation.
Scheff PA; Paulius VK; Huang SW; Conroy LM
Appl Occup Environ Hyg; 2000 Nov; 15(11):824-34. PubMed ID: 11062927
[TBL] [Abstract][Full Text] [Related]
8. An experimental study on effects of increased ventilation flow on students' perception of indoor environment in computer classrooms.
Norbäck D; Nordström K
Indoor Air; 2008 Aug; 18(4):293-300. PubMed ID: 18422569
[TBL] [Abstract][Full Text] [Related]
9. Regular and temporary occupants' perceptions of satisfaction in tertiary education buildings.
Bortolini R; Forcada N
Ergonomics; 2021 Jul; 64(7):926-942. PubMed ID: 33523767
[TBL] [Abstract][Full Text] [Related]
10. Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings.
Wu PC; Li YY; Chiang CM; Huang CY; Lee CC; Li FC; Su HJ
Indoor Air; 2005 Feb; 15(1):19-26. PubMed ID: 15660566
[TBL] [Abstract][Full Text] [Related]
11. Methods to reduce the CO(2) concentration of educational buildings utilizing internal ventilation by transferred air.
Kalema T; Viot M
Indoor Air; 2014 Feb; 24(1):71-80. PubMed ID: 23841677
[TBL] [Abstract][Full Text] [Related]
12. Ventilation conditions and their influence on thermal comfort in examination classrooms in times of COVID-19. A case study in a Spanish area with Mediterranean climate.
Miranda MT; Romero P; Valero-Amaro V; Arranz JI; Montero I
Int J Hyg Environ Health; 2022 Mar; 240():113910. PubMed ID: 34968975
[TBL] [Abstract][Full Text] [Related]
13. Indoor Environmental Quality in Mechanically Ventilated, Energy-Efficient Buildings vs. Conventional Buildings.
Wallner P; Munoz U; Tappler P; Wanka A; Kundi M; Shelton JF; Hutter HP
Int J Environ Res Public Health; 2015 Nov; 12(11):14132-47. PubMed ID: 26561823
[TBL] [Abstract][Full Text] [Related]
14. Understanding teachers' experiences of ventilation in California K-12 classrooms and implications for supporting safe operation of schools in the wake of the COVID-19 pandemic.
Sanguinetti A; Outcault S; Pistochini T; Hoffacker M
Indoor Air; 2022 Feb; 32(2):e12998. PubMed ID: 35170085
[TBL] [Abstract][Full Text] [Related]
15. Summary of human responses to ventilation.
Seppänen OA; Fisk WJ
Indoor Air; 2004; 14 Suppl 7():102-18. PubMed ID: 15330778
[TBL] [Abstract][Full Text] [Related]
16. BIM and Data-Driven Predictive Analysis of Optimum Thermal Comfort for Indoor Environment.
Gan VJL; Luo H; Tan Y; Deng M; Kwok HL
Sensors (Basel); 2021 Jun; 21(13):. PubMed ID: 34199042
[TBL] [Abstract][Full Text] [Related]
17. Response to the COVID-19 Pandemic in Classrooms at the University of the Basque Country through a User-Informed Natural Ventilation Demonstrator.
Rodríguez-Vidal I; Martín-Garín A; González-Quintial F; Rico-Martínez JM; Hernández-Minguillón RJ; Otaegi J
Int J Environ Res Public Health; 2022 Nov; 19(21):. PubMed ID: 36361439
[TBL] [Abstract][Full Text] [Related]
18. The effects of indoor air quality on performance and productivity.
Wyon DP
Indoor Air; 2004; 14 Suppl 7():92-101. PubMed ID: 15330777
[TBL] [Abstract][Full Text] [Related]
19. Field Measurements and Analysis of Indoor Environment, Occupant Satisfaction, and Sick Building Syndrome in University Buildings in Hot Summer and Cold Winter Regions in China.
Weng J; Zhang Y; Chen Z; Ying X; Zhu W; Sun Y
Int J Environ Res Public Health; 2022 Dec; 20(1):. PubMed ID: 36612874
[TBL] [Abstract][Full Text] [Related]
20. CO
Di Gilio A; Palmisani J; Pulimeno M; Cerino F; Cacace M; Miani A; de Gennaro G
Environ Res; 2021 Nov; 202():111560. PubMed ID: 34224708
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]