These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 34585376)

  • 1. A novel method for cyanide quantification in human whole blood using ion chromatography with amperometric detection and its application to cyanide intoxication cases.
    Sim J; Kim M; Kim S; Yang W
    J Forensic Sci; 2022 Jan; 67(1):353-357. PubMed ID: 34585376
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Modified congener analysis: Quantification of cyanide in whole blood, other body fluids, and diverse beverages.
    Sundermann TR; Schmitt G; Bartel M
    Drug Test Anal; 2021 Feb; 13(2):412-418. PubMed ID: 32939996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnosis of lethal cyanide poisoning. Analysis by Anion-Exchange Chromatography with Pulsed Amperometric Detection.
    Zuccarello P; Carnazza G; Raffino C; Barbera N
    J Forensic Sci; 2022 Jul; 67(4):1617-1623. PubMed ID: 35478404
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An improved method for cyanide determination in blood using solid-phase microextraction and gas chromatography/mass spectrometry.
    Frison G; Zancanaro F; Favretto D; Ferrara SD
    Rapid Commun Mass Spectrom; 2006; 20(19):2932-8. PubMed ID: 16941546
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Old Poison, New Problem: Cyanide Fatal Intoxications Associated with Internet Shopping.
    Wachełko O; Chłopaś-Konowałek A; Zawadzki M; Szpot P
    J Anal Toxicol; 2021 Apr; ():. PubMed ID: 33851707
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid measurement of free cyanide in liquor by ion chromatography with pulsed amperometric detection.
    Wu W; Xiao Q; Zhang P; Ye M; Wan Y; Liang H
    Food Chem; 2015 Apr; 172():681-4. PubMed ID: 25442607
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ion Chromatography with Pulsed Amperometric Detection for Determining Cyanide in Urine and Meconium Samples.
    Jaszczak-Wilke E; Kozioł K; Kiełbratowska B; Polkowska Ż
    Molecules; 2021 Aug; 26(15):. PubMed ID: 34361828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Distribution of cyanide in heart blood, peripheral blood and gastric contents in 21 cyanide related fatalities.
    Rhee J; Jung J; Yeom H; Lee H; Lee S; Park Y; Chung H
    Forensic Sci Int; 2011 Jul; 210(1-3):e12-5. PubMed ID: 21570785
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Blood cyanide determination in two cases of fatal intoxication: comparison between headspace gas chromatography and a spectrophotometric method.
    Gambaro V; Arnoldi S; Casagni E; Dell'acqua L; Pecoraro C; Froldi R
    J Forensic Sci; 2007 Nov; 52(6):1401-4. PubMed ID: 18093070
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of cyanide in bamboo shoots by microdiffusion combined with ion chromatography-pulsed amperometric detection.
    Ding M; Wang K
    R Soc Open Sci; 2018 Apr; 5(4):172128. PubMed ID: 29765664
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Screening Method for Cyanide in Blood by Dimethoxytriazinyl Derivatization-GC/MS.
    Yamaguchi A; Miyaguchi H
    J Chromatogr Sci; 2021 Jan; 59(1):1-6. PubMed ID: 33147618
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of ion chromatography with pulsed amperometric detection for the determination of trace cyanide in biological samples, including breast milk.
    Jaszczak E; Kozioł K; Kiełbratowska B; Polkowska Ż
    J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Mar; 1110-1111():36-42. PubMed ID: 30776613
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection.
    Christison TT; Rohrer JS
    J Chromatogr A; 2007 Jun; 1155(1):31-9. PubMed ID: 17350635
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Online liquid chromatography-tandem mass spectrometry cyanide determination in blood.
    Lacroix C; Saussereau E; Boulanger F; Goullé JP
    J Anal Toxicol; 2011 Apr; 35(3):143-7. PubMed ID: 21439149
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.
    Jaszczak E; Ruman M; Narkowicz S; Namieśnik J; Polkowska Ż
    J Anal Methods Chem; 2017; 2017():7157953. PubMed ID: 29348966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of cyanide in blood by reaction head-space gas chromatography.
    Felby S
    Forensic Sci Med Pathol; 2009; 5(1):39-43. PubMed ID: 19291430
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A micro-chemiluminescence determination of cyanide in whole blood.
    Lv J; Zhang Z; Li J; Luo L
    Forensic Sci Int; 2005 Feb; 148(1):15-9. PubMed ID: 15607585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new specific method to detect cyanide in body fluids, especially whole blood, by fluorimetry.
    Felscher D; Wulfmeyer M
    J Anal Toxicol; 1998 Sep; 22(5):363-6. PubMed ID: 9737330
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cyanide quantification in post-mortem biological matrices by headspace GC-MS.
    Desharnais B; Huppé G; Lamarche M; Mireault P; Skinner CD
    Forensic Sci Int; 2012 Oct; 222(1-3):346-51. PubMed ID: 22771200
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of Cyanide in Blood for Forensic Toxicology Purposes-A Novel Nci Gc-Ms/Ms Technique.
    Osak M; Buszewicz G; Baj J; Teresiński G
    Molecules; 2021 Sep; 26(18):. PubMed ID: 34577109
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.